Antifrost protection 

CAUTION 

IMPORTANT! 

When the unit is out of service, remember to arrange in good  
time  for  the  entire  water  content  in  the  circuit  to  be  drained  
down. 

IMPORTANT! 

Mixing the water with glycol modifies the performance of the  
unit. 
Pay  attention  to  the  safety  instructions  regarding  ethylene  
glycol which are printed on the container. 

If the unit is not used during the winter period,the water contained in  
the system may freeze. 

Draining  the  water  circuit  needs  to  be  undertaken  in  good  
time.However, if  the  operation  of  draining  the  systemis  felt  to  be  too  
laborious, a  suitable  quantity  of  antifreeze  may  be  mixed  with  the  
water instead.  

3.2.2 Electrical connections 

WIRING

CAUTION 

IMPORTANT! 

Machine  commissioning  or  the  first  start  up  must  be  carried  
out  by  skilled  personnel  qualified  to  work  on  this  type  of  
product. 

DANGER! 

Before  starting  up,make  sure  that  the  installation  and  
electrical  connections  have  been  carried  out  in  accordance  
with the instructions in this manual. Also make sure that there  
are  no  unauthorised  persons  in  the  vicinity  of  the  machine  
during these operations. 

3.2.3   Startup instructions

Pipeline system has been vacuumed before initial start the 
 equipment  

Check that the voltage and the frequency of the electrical supply  
correspond to 220-240V single phase at 50Hz; that the available  
power is suffcient for the running the equipment; and that the 
supply cables are of adequate section for the maximum current 

 
which will be required. 
 
Make  sure  that  the  electrical  supply  system  complies  with  
current national safety regulations. 

Electrical  connections  must  be  made  in  accordance  with  the  
wiring diagrams supplied with the machine.For connection to the  
electrical  supply  network,use  double-insulated  flexible  
cable, twin pole + earth, section 1.5mm

2

  , type H05RN-F. 

Pass  the  supply  cable  through  the  slot  beside  the  air  filter. Use 
the  cable  clamp  provided  on  the  inner  side  of  the  panel  to  
secure  the  supply  cable  and  the  connecting  cables, and  strip  
only the length of cable needed to go into the connector block. 
In  the  event  that  the  unit  is  mounted  on  a  metal  surface,earth  
connections  must  be  made  in  compliance  with  local  
regulations.If  the  optional  extra  electric  heating  element  is  
fitted,a  separate  power  supply  must  be  provided. Use  double- 
insulated  flexible  cable, twin  pole  +  earth,section  2.5mm

2

, type  

H05RN-F. 

See product nameplate wiring.

1    Remove the connecting pipe’s side cover panel by cross  

      screwdriver.   

2    Remove the bolts that showed at the figure by slotted screw 

      driver. Start up the pump to circulate the pipeline water and  

      vacuum air from the system until there have water flow out  

      from bolt holes, and then  tighten the boltsthe system.     

3     Shutdown the sestem that showed at the figure by slotted  

      screwed and replace the side cover panel. 

Fig.3-10 

CAUTION 

IMPORTANT! 

Electrical  connection  of  the  unit  must be  carried  out  by  
qualified  personnel  in  compliance  with  the  regulations  in  
effect in the country where the unit is installed.The company  

DANGER! 

Always install a general automatic switch in a protected area  
near  the  appliance  with  an  adequate  capacity  characteristic  
delayed curve with sufficient breaking power.There should be  
a  minimum  distance  of  3mm  between  the  contacts. Earth  
connection is compulsory by law to ensure user safety while  
the machine is in use. 

shall not be held liable for damage to persons or property  
caused  by incorrect electrical connection. 

    

MODEL

POWER 

CIRCUIT BREAKER/FUSE(A) 

PHASE 

FREQUENCY AND VOLT 

ALL

1-phase 

220-240V~   50Hz 

15/15 

      

      

      

Table 3-2

The  power  cord  type  designation  is  H05RN-R  or 
above/H07RN-F. 
 
This appliance can be children  aged from 8 yeas and above 
and  persons  with  reduced  physical,sensory  or  mental 
capabilities or lack of experience and knowledge if they have 
been  given  supervision  or  instruction  concerning  use  of  the 
appliance  in  a  safe  way  and  understand  the  hazards 
involved.Childern shall not play with the appliance.Cheaning 
and user maintenance shall not be made by children without 
supervision. 
 
The  appliance  shall  be  installed  in  accordance  with  national 
wiring regulations. 
 
 
 
 

Installation manual

Universal FCU DC

10

Содержание MUC-W7/CE

Страница 1: ...English www mundoclima com www mundoclima com Universal FCU DC Installation manual MUC W7 CL04580 to CL04594 MUC W7 CE MUC W7 SE...

Страница 2: ...INGLE PHASE one phase L and one neutral N with his grounded power GND switch Any breach of these specifications involve a breach of the warranty conditions provided by the manufacturer In line with th...

Страница 3: ...lace of purchase for more information Excessive refrigerant in a closed ambient can lead to oxygen deficiency Use the attached accessories parts and specified parts for installation otherwise it will...

Страница 4: ...cks Be sure to install an earth leakage breaker Failure to install an earth leakage breaker may result in electric shocks Connect the outdoor unit wires then connect the indoor unit wires You are not...

Страница 5: ...ction as a ceiling mounted air handling terminal supplied through ducting or panelling any other use is expressly prohibited Installation of the machine in an explosive environment is also forbidden C...

Страница 6: ...sable to run the unit at maximum speed for several hours To ensure correct air intake the air filter must be cleaned at least once a month or more frequently if the unit is being used in very dusty en...

Страница 7: ...lectrical components Also make sure that there are no obstacles or people along the route to avoid the danger of collisions or crushing and to prevent the lifting or handling device from turning over...

Страница 8: ...at the time of installation For installation follow the instructions set out below Remove the external casing in versions CE and SE unscrewing the screws which secure it to the structure as following...

Страница 9: ...10 mm thick or install the auxiliary drain Pour water into the condensation collector tray and check that the liquid drains properly following it right through to the exit of the draintube If it does...

Страница 10: ...ecting cables and strip only the length of cable needed to go into the connector block In the event that the unit is mounted on a metal surface earth connections must be made in compliance with local...

Страница 11: ...no obstructions in the condensation drain tube which could prevent the normal flow of water 1 2 4 3 remove the casing of the machine start the system and run for a few minutes stop the system slacken...

Страница 12: ...procedures The unit should only be dismantled by a firm authorized for the disposal of scrap machinery The unit as a whole is composed of materials considered as secondary raw materials and the follo...

Страница 13: ...00 1200 900 700 500 D mm 1226 1226 926 726 526 Installation manual Universal FCU DC Model MUC 07 W7 CE MUC 11 W7 CE MUC 16 W7 CE MUC 19 W7 CE MUC 24 W7 CE 13 220 Rear view 105 46 D C 150 150 220 592 1...

Страница 14: ...E A C 212 87 Water connection Rear view 46 105 203 291 185 258 Fig 4 6 Fig 4 7 Fig 4 8 A mm B mm C mm D mm Model MUC 07 W7 SE MUC 11 W7 SE MUC 16 W7 SE MUC 19 W7 SE MUC 24 W7 SE 550 526 500 532 750 72...

Страница 15: ...0 471 V F Hz 220 240 1 50 220 240 1 50 220 240 1 50 220 240 1 50 220 240 1 50 W 16 33 29 39 116 MPa 1 6 1 6 1 6 1 6 1 6 C 65 65 65 65 65 inch 3 4 3 4 3 4 3 4 3 4 mm 16 16 16 16 16 Version SE W x H x...

Страница 16: ...ASK FOR MORE INFORMATION Phone 34 93 446 27 81 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 www mundoclima com...

Отзывы: