6.    FOLLOWING SYMPTOMS ARE NOT AIR

       CONDITIONER TROUBLES

Symptom 1: The system does not operate

Symptom 2: Change into the fan mode during

                      cooling mode       

                      

Symptom 3: White mist comes out of a unit

Sptom 4: Noise of air conditionerscooling 

The air conditioner does not start immediately after the ON/OFF 
button on the romote controller is pressed. 
If the operation lamp lights, the system is in normal condition.To 
prevent overloading of the compressor motor, the air 
conditioner starts 5 minutes  after  it  is turned ON.

If the operation lamp and the "

PRE-DEF indicator(cooling and 

heating type) or fan only indicator(cooling only type)"

 light, it 

means you choose the heating model, When just starting, if the 
compressor has not started, the indoor unit  appears "anti cold 
wind" protection because of its overlow outlet temperature.

In order to prevent the indoor evaporator frosting, the system 
will change into fan mode automatically, restore to the cooling 
mode after soon.

When the room temperature drops to the set temperature, the 
compressor goes off and the indoor unit changes to fan mode; 
when the temperature rises up, the compressor starts again. It 
is same in the heating mode.

Symptom 3.1: Indoor unit

 Symptom 3.2:  Indoor unit, outdoor unit

Symptom 4.1: Indoor unit

When humidity is high during cooling operation If the interior of 
an indoor unit is extremely contaminated, the temperature 
distribution inside a room becomes uneven. It is necessary to 
clean the interior of the indoor unit. Ask your dealer for details 
on cleaning the unit. This operation requires a qualified service 
erson

When the system is changed over to heating operation after 
defrost operation Moisture generated by defrost becomes 
steam and is exhausted.  

A continuous low "shah" sound is heard when the system is in 
cooling operation or at a stop. 
When the drain pump (optional accessories) is in operation,this 
noise is heard.

A "pishi-pishi" squeaking sound is heard when the system stops 
after heating operation. 
Expansion and contraction of plastic parts caused by 
temperature change make this noise. 

Symptom 4.2:  Indoor unit, outdoor unit 

A continuous low hissing sound is heard when the system is in 
operation. 
This is the sound of refrigerant gas flowing through both indoor 
and outdoor units. 

A hissing sound which is heard at the start or immediately after 
stopping operation or defrost operation. 
This is the noise of refrigerant caused by flow stop or flow 
change. 

Symptom 4.3: Outdoor unit 

When the tone of operating noise changes. 
This noise is caused by the change of frequency.

.

Symptom 5: Dust comes out of the unit 

Symptom 6: The units can give off odours

When the unit is used for the first time in a long time. 
This is because dust has gotten into the unit.

The unit can absorb the smell of rooms, furniture, cigarettes, 
etc., and then emit it again. 

Symptom 7: The outdoor unit fan does not       

                      spin.

During operation. The speed of the fan is controlled in order to 
optimize product operation. 

The operation lamp is flashing rapidly (twice every second)
This lamp is still flashing rapidly after turn off the power and turn 
on again.

Remote controller receives malfunction or the button does not 
work well.

A safety device such as a fuse, a breaker frequently actuates.

Obstacles and water enter the unit.

Water leaks from indoor unit.

Other malfunctions.

7.    TROUBLESHOOTING

If one of the following malfunctions occur, stop operation, shut 
off the power, and contact with your dealer.

If the system does not properly operate except the above 
mentioned cases or the above mentioned malfunctions is 
evident, investigate the system according to the following 
procedures. 

(see in Table 7-1)

7.1.      Troubles and causes of air conditioner

19

Owner's manual

Mini MVD V4+

Содержание mini mvd v4+

Страница 1: ...OUTDOOR UNIT CL23269 to CL23271 English MINI MVD V4 20 22 4 and 26kW Installation and owner s manual MVD www mundoclima com...

Страница 2: ...CONTENTS Installation manual 3 Owner s manual 15 2 Installation and owner s manual Mini MVD V4...

Страница 3: ...nstall in a place that might increase the vibration of the unit To avoid personal injury with sharp edges be careful when handling parts Perform installation work properly according to the Installatio...

Страница 4: ...utdoor unit is installed in an elevated position make sure it s four feet securely installed There must be sufficient space for carrying in the unit A place where the drain water does not make any pro...

Страница 5: ...r unit power cord and connecting wire at least 1m away from TV set or radio to prevent noise or picture interference Strong wind Strong wind 3 2 Installation space Unit mm 300 600 300 3000 Wall or obs...

Страница 6: ...the frozen condensed water will block up the water outlet please pull out the rubber stopper of the reserve water outlet If that still fails to satisfy for the water draining please knock open the ot...

Страница 7: ...Connecting method main pipe The branch pipes of indoor unit The pipe after the first branch do not drect connect with the indoor unit The pipe after the branch connect with the indoor unit The pipes...

Страница 8: ...refrigerant pipe m The number of bends When the outdoor unit connects one indoor unit 4 6 Illustration Outdoor Unit Take Model 260 for example Caution Suppose in the displayed piping system the total...

Страница 9: ...gas side main pipe size Inner branch pipes are a f the size selection please refers to Table4 6 Note The max length of the branch pipe should not longer than 15m Indoor unit branch pipe The main pipe...

Страница 10: ...uum pump to do the vacuum never using refrigerant to expel the air Vacuuming should be done from both liquid side and gas side simultaneously Calculate the added refrigerant according to the diameter...

Страница 11: ...n of the outdoor unit P Q E L N P Q E L N P Q E L N P Q E L N B C N A K2 K2 E O K1 K1 A E Y E P X Q E Power supply for the outdoor unit monitor Outdoor unit Outdoor unit monitor Optional L N L N K1 K2...

Страница 12: ...to the signal cable insert electric wires in their respective electric wire pipes and reserve a proper inter wire distance distance between power cables lower than 10 A 300 mm lower than 50 A 500 mm U...

Страница 13: ...g dew will be caused The air conditioners can connect with Central Control Monitor CCM Before operation please wiring correctly and set system address and network address of indoor units NOTE Single p...

Страница 14: ...ditioner A C adopts inncouous and nonflammable refrigerant The locating room of the A C should big engough that any refrigerant leakage is unable to reach critical thickness So certain esssential acti...

Страница 15: ...ce the unit by yourself Ask a qualified service person to perform this work Do not dispose this product as unsorted municipal waste Collection of such waste separately for special treatment is necessa...

Страница 16: ...detector is installed Be sure the air conditioner is grounded In order to avoid electric shock make sure that the unit is grounded and that the earth wire is not connected to gas or water pipe lightn...

Страница 17: ...splay panel of indoor unit flashes And then unit will auto restart Mishandling in operation If mishandling happens because of lighting or mobile wireless please shut off the manual power switch and tu...

Страница 18: ...in 30 minutes 8 Voltage protection fault or a lack of Phase B Phase N E5 9 10 11 DC fan motor fault Discharge temperature sensor fault E6 EA E7 2 times of E6 protection in 10 minutes EB P0 HF E2 12 1...

Страница 19: ...rd when the system is in cooling operation or at a stop When the drain pump optional accessories is in operation this noise is heard A pishi pishi squeaking sound is heard when the system stops after...

Страница 20: ...indoor unit heat exchanger is dirty The air filter is dirty Inlet outlet of indoor outdoor units is blocked Doors and windows are open Sunlight directly shine Too much heat resource Outdoor temp is t...

Страница 21: ...unit when the ON OFF button is pressed Directly transmit the signal transmitter of the remote controller to the infrared signal receiver of the indoor unit and then repeatly push the ON OFF button tw...

Страница 22: ...ASK FOR MORE INFORMATION Phone 34 93 446 27 80 eMail info mundoclima com TECHNICAL ASSISTANCE Phone 34 93 652 53 57 www mundoclima com MVD...

Отзывы: