7
Linking up the smoke detectors
We recommend performing the registration of all smoke detectors on a table.
The following steps must be carried out within 20 seconds. Please read the inst-
ructions before performing the individual steps.
6. Take a smoke detector from the group and designate it as the “master”.
The remaining detectors are all assigned to be secondary detectors (“slaves”).
7. Press the LEARN–button on the “master” detector several times until it lights
up green.
(D)
8. Now press the LEARN–button on all the secondary “slave” detectors until they
light up red.
(D)
9. Test: press the TEST–button
(C)
on the “master” detector until all the smoke
detectors emit a signal. At this point, the LED on the “master” detector will
flash red and the LEDs on the secondary detectors will flash green. After a few
seconds the alarm signal will stop.
The smoke detectors are now linked.
Creating a large group
If the required number of number of devices cannot register within 20 seconds,
then a smaller group can be created first.
This group can then be expanded by adding additional “slave” detectors. For each
detector in the existing group, the TEST–button
(C)
can be pressed down until all
the other detectors react and the additional detectors are added to the group.
Creating single groups
Single groups can also be created in a house. For this purpose, it is first
necessary to delete the memory of each smoke detector.
• Remove all batteries from the smoke detectors and re-insert after 3 minutes.
• Register each detector as a “slave”, repeatedly press the LEARN–button
(D)
(the red LED must light up) and press the TEST–button
(C)
. This will only trigger
the alarm on this unit.
If, after creating the first group (refer to the installation test) you want to create
a second group, wait at least 5 minutes and then perform the same learning pro-
cess for the new group. If a detector is to be added to the other group, then this
detector can only be set up as a new “slave” to the “master” of the group. Only
“slave” detectors can be swapped within the group.
Note
If an alarm is triggered in one group, the green LEDs in the other
group will flash (as a display) — but no alarm signal will sound.
GB