2
GB
User Manual
LM-109C - Smoke detector with VdS approval
Scope of supply
• Smoke detector with VdS approval
• Installation kit (one per smoke detector)
• Instructions
Specifications
Product:
Smoke detector with VdS approval
Battery operation:
Built-in 3 V lithium battery (CP952434)
Current consumption: Standby < 2 µA, Alarm < 120 mA
Alarm volume:
≥ 85 dB within a range of 3 metres
Muting:
Approx. 10 min per press of the button
Warning signal:
Indicates weak battery
Certified:
EN 14604:2005 - Smoke alarm devicesn
General information
Please read through the entire operating instructions before putting the smoke
detector into operation.
This latest generation of smoke detector has an integral microprocessor and
automatic contamination compensation; this guarantees consistent functional
reliability of the smoke chamber for a period of 10 years.
It is not capable of detecting heat, gas or fire. If installed correctly, the smoke
detector provides sufficient warning. In the event of a fire, this provides enough
time to leave the house and notify the fire service. The alarm device is intended
to detect smoke; it is not capable of preventing a fire.
IMPORTANT INFORMATION
Smoke detectors warn of smoke and not heat, gas or fire.
Only test the smoke detector using the „Test“ button, or use a commercially
available test spray. Do NOT under any circumstances intentionally attempt to
generate smoke by any other means, as this could put you in a life-threatening
situation or damage the smoke detector sensors.
Cigarette smoke will not trigger an alarm unless large quantities are blown direc-
tly into the smoke detector sensor.
Do not paint the smoke detector and do not cover any of the openings.
Commissioning and installation
The smoke detector must be activated before installation. As the battery is in-
stalled in the device, it must first be activated. To do this, press the red switch on
the back of the unit (beneath the mounting plate). After pressing the switch, the
smoke detector is ready for use.
G217010_2017-02-10