GENERAL 

The SDTA-02 is designed to transform high-AC currents and voltages into a current or 
voltage scale compatible with analog channels on MULTITEL’s monitoring systems, 
such as the RPM-1000/C, the MXP2 188 and the MIRADOR. 
 
 

3.2

 

ANALOG CHANNEL SETUP 

The SDTA-02 will send its measurements to several analog channels on your 
MULTITEL monitoring system. In order to operate properly, those analog-input 
channels need to be programmed with the proper scaling factor according to the AC 
voltage or AC current input range (see Table 2). Please refer to the user’s manual of your 
MULTITEL monitoring system for a complete description of steps to follow in order to 
configure it accordingly. 
 

Table 2 – Current and voltage data for analog channel configuration 

 

INPUT RANGE 

SCALE 

INPUT SOURCE 

0-240 VAC 
0-600 VAC 

565 

1400 

Voltage 
Voltage 

 

3.3

 

MULTITEL MONITORING SYSTEM CONFIGURATION SETUP 

The SDTA-02 has been set in the factory according to your needs. However, you should check 
that setting is correct in order to avoid erratic readings (see the following table). 
 

Содержание SDTA-02

Страница 1: ...SDTA 02 Step Down Transformer Adapter User s Manual...

Страница 2: ...t shall 1 Keep all information contained herein confidential and shall protect same in whole or in part from disclosure and dissemination to all third parties and 2 Use the same for operating and main...

Страница 3: ...2...

Страница 4: ...ENT 10 4 2 MOUNTING THE SYSTEM 10 4 3 WIRING AND CONNECTING 11 4 3 1 GENERAL INFORMATION 12 4 4 ALERNATIVE VOLTAGE MEASUREMENTS 12 5 MAINTENANCE 16 5 1 CALIBRATION 16 5 2 TROUBLESHOOTING 16 5 2 1 Gene...

Страница 5: ...93 06 25 First English issue Pierre Poulin 1 01 94 10 12 1 02 97 05 08 Minor modifications and new formatting Fran ois Dionne 1 1 00 06 16 New certification information for CSA c and CSA US Gilles Bel...

Страница 6: ...onfigurations available for the SDTA 02 interface Table 1 SDTA 02 Models and Part Numbers DESCRIPTION MULTITEL PART SDTA 02 240 VAC 3 phases M 4173 SDTA 02 600 VAC 3 phases M 4178 These models are CSA...

Страница 7: ...SDTA 02 GENERAL INFORMATION www multitel com support multitel com 6 Figure 1 Physical Aspect...

Страница 8: ...put impedance Voltmeter 240 V 2400 600 V 6000 Ammeter 0 2 Output signal Voltmeter 17 VAC 2 nominal inputs max 28 VAC Ammeter 500 mVAC 2 2 ENVIRONMENTAL Temperature Operation 0 C to 50 C 32 F to 122 F...

Страница 9: ...analog input channels need to be programmed with the proper scaling factor according to the AC voltage or AC current input range see Table 2 Please refer to the user s manual of your MULTITEL monitor...

Страница 10: ...w multitel com support multitel com 9 Table 3 SDTA 02 Setup PHASE JUMPER MXP2 MIRADOR RPM 1000 C Phase A JP5 OFF ON JP6 ON OFF JP9 ON OFF Phase B JP3 OFF ON JP4 ON OFF JP8 ON OFF Phase C JP1 OFF ON JP...

Страница 11: ...S multimeter with clamp on meter Bx cable 14 2 Belden cable 9305 or 20 AWG stranded NOTE Unpack and verify with the Material list that all the material is received and in good condition 4 2 MOUNTING T...

Страница 12: ...on of the SDTA 02 4 3 WIRING AND CONNECTING IMPORTANT This Cabling and connecting section provides the general installation procedures and describes how to interconnect and put into service a SDTA 02...

Страница 13: ...low the manufacturer s instruction supplied with the CTs Make sure that polarity dots on CTs is respected 4 4 ALERNATIVE VOLTAGE MEASUREMENTS Connect each breaker output max 15 Amp for each phase A B...

Страница 14: ...SDTA 02 INSTALLATION www multitel com support multitel com 13 Figure 3 AC Current and Voltage Measurements...

Страница 15: ...USE TYPE PIN NAME USE TYP E 1 VOUTC2 Voltmeter phase C common output lead OUT 5 VOUTB1 Voltmeter phase B output lead OUT 2 VOUTC1 Voltmeter phase C output lead OUT 6 N C Not connected N A 3 N C Not co...

Страница 16: ...TYPE PIN NAME USE TYPE 1 VINA1 Phase A VAC input lead IN 5 VINB2 Phase B VAC common input lead IN 2 VINA2 Phase A VAC common input lead IN 6 N C Non connected N A 3 N C Not connected N A 7 VINC1 Phase...

Страница 17: ...er to calibrate the erratic measurement 1 Configure the MULTITEL monitoring system s analog channel according to specifications 2 Read the source value with an RMS multimeter or RMS clamp on meter 3 A...

Страница 18: ...le 2 5 The wiring is compliant with specifications in the SDTA 02 connector definition 6 If all of these possible causes are not true your SDTA 02 may be defective refer to Multitel s Customer Service...

Отзывы: