Chapter 2 – Installing Modems in the 

Rack 

Before

 

You

 

Begin

 

The

 

MultiModemZDX

 

modems

 

are

 

shipped

 

with

 

the

 

DTR

 

signal

 

controlled

 

by

 

the

 

interface

 

and

 

the

 

modem’s

 

Command

 

mode

 

enabled.

 

With

 

rack

mount

 

modems,

 

it

 

is

 

assumed:

 

 

Modems

 

are

 

in

 

a

 

central

 

site

 

computer

 

environment,

 

with

 

the

 

modems

 

connected

 

to

 

a

 

mini

 

or

 

mainframe

 

computer.

  

 

The

 

main

 

purpose

 

of

 

the

 

modems

 

is

 

to

 

automatically

 

answer

 

incoming

 

calls

 

from

 

remote

 

users.

 

Disable

 

command

 

mode

 

unless

 

you

 

want

 

to

 

give

 

the

 

modem

 

commands.

 

Leaving

 

Command

 

mode

 

enabled

 

offers

 

the

 

possibility

 

of

 

a

 

user

 

calling

 

into

 

the

 

modem

 

and

 

reconfiguring

 

it,

 

or

 

causing

 

it

 

to

 

dial

 

out.

 

Refer

 

to

 

the

 

appropriate

 

modem

 

owner’s

 

manual

 

to

 

configure

 

the

 

modem

 

for

 

your

 

application.

 

Safety

 

Recommendations

 

Observe

 

the

 

following

 

safety

 

recommendations

 

when

 

installing

 

a

 

Multi

Tech

 

ZDX

 

Rack.

 

 

Never

 

install

 

telephone

 

wiring

 

during

 

a

 

lighting

 

storm.

 

 

Never

 

install

 

telephone

 

jacks

 

in

 

wet

 

locations

 

unless

 

the

 

jack

 

is

 

specifically

 

designed

 

for

 

wet

 

locations.

 

 

Never

 

touch

 

insulated

 

telephone

 

wires

 

or

 

terminals

 

unless

 

the

 

telephone

 

line

 

has

 

been

 

disconnected

 

at

 

the

 

network

 

interface.

 

 

Use

 

caution

 

when

 

installing

 

or

 

modifying

 

telephone

 

lines.

 

 

Avoid

 

using

 

a

 

telephone

 

(other

 

than

 

a

 

cordless

 

type)

 

during

 

an

 

electrical

 

storm.

 

There

 

may

 

be

 

a

 

remote

 

risk

 

of

 

electrical

 

shock

 

from

 

lighting.

 

 

Do

 

not

 

use

 

the

 

telephone

 

to

 

report

 

a

 

gas

 

leak

 

in

 

the

 

vicinity

 

of

 

the

 

leak.

 

 

This

 

product

 

is

 

for

 

use

 

only

 

with

 

listed

 

computers,

 

or

 

equivalent.

 

Installing

 

the

 

Rack

 

and

 

Modems

 

To

 

install

 

the

 

ZDX

 

rack,

 

with

 

up

 

to

 

12

 

ZDX

 

modems

 

in

 

the

 

rack.

 

1. 

Unpack

 

the

 

rack

 

and

 

check

 

all

 

items

 

against

 

the

 

shipping

 

list

 

to

 

ensure

 

that

 

you

 

have

 

received

 

the

 

correct

 

items.

 

Rack

 

components

 

include:

 

 

Rack

 

 

Power

 

cord

 

 

Owner's

 

manual

 

2. 

Inspect

 

the

 

rack

 

for

 

visible

 

shipping

 

damage.

 

 

 

If

 

you

 

see

 

damage,

 

do

 

not

 

power

on

 

the

 

rack.

 

Contact

 

Multi

Tech's

 

Technical

 

Support

 

for

 

advice.

 

 

If

 

you

 

do

 

not

 

see

 

damage,

 

mount

 

the

 

rack

 

in

 

a

 

standard

 

19

inch

 

wide

 

rack

 

enclosure.

 

3. 

Open

 

the

 

rack

 

front

 

door.

 

4. 

Unpack

 

the

 

ZDX

 

modems

 

that

 

you

 

want

 

to

 

install

 

in

 

the

 

rack.

 

Note:

 

Due

 

to

 

height

 

clearance

 

do

 

not

 

attach

 

the

 

plastic

 

feet

 

to

 

the

 

modem.

  

Содержание ZDX Series

Страница 1: ...RackMountedModems ZDX Series Modem Racks User s Guide...

Страница 2: ...ty statement Updated the Technical Support section B 12 12 2011 Applied styles Removed product CD Warranty For Warranty information see the Multi Tech Web site at http www MultiTech com Patents This d...

Страница 3: ...r 2 Installing Modems in the Rack 5 Before You Begin 5 Safety Recommendations 5 Installing the Rack and Modems 5 Tips for Mounting Modems in the Rack 7 Powering Up 7 Appendix A Class A Notice and Safe...

Страница 4: ...ons The rack is 19 inches wide by 5 inches high You can mount the rack in the same cabinet as your computer or you can enclose the rack in a separate cabinet To install modems into the rack simply ope...

Страница 5: ...he jack is specifically designed for wet locations Never touch insulated telephone wires or terminals unless the telephone line has been disconnected at the network interface Use caution when installi...

Страница 6: ...ack You may have to hold the modem in place from the front while plugging in the power cable The top power cable supplies power to the top 6 modems and the bottom power cable supplies power to the bot...

Страница 7: ...tion devices and supply wiring Slots and openings in the cabinet help provide ventilation To ensure reliable operation of the product and to protect it from overheating maintain a minimum of 1 inch cl...

Страница 8: ...Canada Operation of this device is subject to the following conditions 1 This device may not cause harmful interference and 2 this device must accept any interference that may cause undesired operati...

Страница 9: ...l conector de alimentaci n de energ a sirve como dispositivo de desconexi n La toma de corriente se debe instalar cerca del equipo y tener un acceso sencillo 3 Para reducir el riesgo de sacudida el ct...

Страница 10: ...inal which is marked with the letter L or coloured red Alimentation Requise C A 90 240V 50 60 Hz 2 0A ATTENTION Pour garantir une protection continue contre tout risque d incendie utilisez toujours de...

Отзывы: