Unless otherwise noted, all values are hexadecimal numbers. Any numeric
values from tables in ITU V.58 are converted to hexadecimal. Multi-digit
values are reported MSD first. Leading 0’s may be deleted. See examples
in Table 5-13.
Monitoring an Active Connection
This command is intended for use after call termination. However, codes are
defined so that a modem can respond before the first call is placed, and during a
call for live monitoring purposes. For example, key 60, call termination, has value
1 defined, indicating that the call is still in progress.
There are at least two ways to do this. First, the DTE could switch the modem to
Online command state, issue the command, capture the responses and then
issue an ATO command. For smoother online monitoring, in-band means defined
in ITU V.80 are recommended if available in the modem. If V.80 methods are
used, each response line shall be a separate extended in-band message.
Notes for Tables
1.
The modem may insert a delay (e.g., 10 ms) between information text lines.
2. The code tables include values for data and fax calls. Some of the codes are
applicable only to data calls (e.g., data compression), some are applicable
only to call origination (e.g., busy, answering signal detection) and some are
applicable only to the answering modem (e.g., calling signal detection).
callCleared codes from 3.6.4/V.58-1994
callCleared: indicates that the DCE has gone on-hook and that the previously
existing network connection has been cleared. These values are hex values,
converted from decimal in V.58. callCleared codes are described in Table 5-12.
Table 5-4. AT#UD Last Call Status Report Format
Key Value(s) Definition
0
2 digits
Diagnostic Command Specification revision number, digit.digit
1
Table 5-5
Call Setup Result code
2
Table 5-6
Multi-media mode
3
Table 5-7
DTE-DCE interface mode
4
String
V.8 CM octet string, same format as V.250, in quotes
5
String
V.8 JM octet string, same format as V.250, in quotes
10
0-2F
Received signal power level, in –dBm (0-43)
11
0-1F
Transmit signal power level, in –dBm (e.g., 0-17)
12
0-64
Estimated noise level, in –dBm (e.g., 10-90)
17
0-FFF
Round Trip delay, in units of ms
18
Table 5-8
V.34 INFO bit map
20
Table 5-9
Transmit Carrier Negotiation Result
21
Table 5-9
Receive Carrier Negotiation Result
22
0-1F40
Transmit Carrier symbol rate (0-8000) in symbol/s
23
0-1F40
Receive Carrier symbol rate (0-8000) in symbol/s
24
0-FA0
Transmit Carrier frequency (0-4000) in Hz
25
0-FA0
Receive Carrier frequency (0-4000) in Hz
26
0-FA00
Initial transmit carrier data rate (0-64000) in bit/s
27
0-FA00
Initial receive carrier data rate (0-64000) in bit/s
30
0-FF
Temporary carrier loss event count
31
0-FF
Carrier Rate re-negotiation event count
32
0-FF
Carrier Retrains requested
33
0-FF
Carrier Retrain requests granted
34
0-FA00
Final transmit carrier data rate in bit/s
35
0-FA00
Final receive carrier data rate in bit/s
40
Table 5-10
Protocol Negotiation Result
41
0-400
Error Control frame size in bytes
42
0-FF
Error control link timeouts in transmission
43
0-FF Error
control link NAKs received
44
Table 5-11
Compression Negotiation Result
50
0-2
Transmit flow control: 0=off; 1=DC1/DC3; 2=V.24 circuit 106/133
51
0-2
Receive flow control: 0=off; 1=DC1/DC3; 2=V.24 circuit 106/133
52
0-FFFFFFFF
Transmit characters sent from DTE
53
0-FFFFFFFF
Received characters sent to DTE
54
0-FFFF
Transmit characters lost (data overrun errors from DTE)