Chapter 5 – AT Commands, S-Registers, and Result Codes
Multi-Tech Systems, Inc. SocketModem MT5600SMI Developer’s Guide
46
Command:
&V1
Display Last Connection Statistics
Description:
Displays the last connection statistics in the following format (shown with
typical results):
TERMINATION REASON
LOCAL REQUEST
LAST TX rate
26400 BPS
HIGHEST TX rate
26400 BPS
LAST RX rate.
49333 BPS
HIGHEST RX rate
49333 BPS
PROTOCOL LAPM
COMPRESSION V42Bis
Line QUALITY
038
Rx LEVEL
015
Highest Rx State
67
Highest TX State
67
EQM Sum
00B4
Min Distance
0000
RBS Pattern
00
Rate Drop
00
Digital Loss
2000
Local Rtrn Count
00
Remote Rtrn Count
00
Flex 9481814347C4
RBS Pattern:
Shows which bits are being robbed in the least significant 6
bytes, e.g., 03 indicates 2 robbed bits in bit positions 0 and 1.
Digital Loss:
Shows if a pad was encountered and if so, what was the digital
loss. 2000 means 0dB.
Flex:
Shows V.8bis information as follows:
First byte: Octet 13 (second byte of manufacturer id, 94 = 56K)
Second byte: Octet 14 (Licensee code: 81 = Conexant)
Third byte: Octet 15 (manufacturer's product capabilities)
Fourth byte: Octet 16 (56K version number)
Fifth byte: Octet 17 (Conexant pump code version number)
Sixth byte: Octet 18 (x-law and controller version number)
Bit 6 Forced/Not forced A-Law/µ-Law
0 = Forced A-Law/µ-Law.
1 = Not forced A-Law/µ-Law.
Bit 5 Select A-Law or µ-Law
0 = Select A-Law.
1 = Select µ-Law.
Bit 4:0 Controller version