Multitech REVEAL RBS301-DWS Скачать руководство пользователя страница 8

HARDWARE SPECIFICATIONS AND INFORMATION

8

Door Window Sensor User Guide

Chapter 3 – Hardware Specifications and Information

Absolute Maximum Ratings

Parameter

Rating

Units

Operating ambient temperature
(indoor version)

-30 to +70

°C

Operating ambient temperature
(outdoor version)

-40 to +70

°C

Storage ambient temperature

-40 to +100

°C

Battery Life

The sensor uses a lithium non-rechargeable battery, capable of an estimated 200,000+ messages.

Note:

Refer to the Sensor Battery Estimator.xlsx spreadsheet on the on the sensor's product page for specific

battery life estimates:

https://www.multitech.com/products/sensors

Battery life depends on the number of transmissions per day. Power required for a message transmission is greater
than the “sleep current” for high power radio technologies (e.g, LoRaWAN).

Different battery types deplete over time with different voltage profiles; a lithium battery maintains high voltage
for the life of the battery with a rapid drop near the end of life, and an alkaline battery has gradual reduction in
voltage over time. Radio Bridge devices are shipped with lithium batteries, which are the recommended
replacement type.

Recommended battery: Panasonic CR123/A

Battery life estimates in the online spreadsheet assume room temperature, meaning temperatures near the
maximum and minimum ratings negatively impact battery life. Battery voltage lowers in cold temperatures, and
internal circuitry needs a minimum voltage to operate properly.

Note:

Battery life will be reduced in cold environments leading to possible device shut down.

The battery voltage is reported by the supervisory messages and a low battery indicator. See the section on
Message Protocol for details.

Содержание REVEAL RBS301-DWS

Страница 1: ...Door Window Sensor User Guide...

Страница 2: ...change without notice and does not represent a commitment on the part of Multi Tech Systems Inc Multi Tech Systems Inc provides this document as is without warranty of any kind expressed or implied in...

Страница 3: ...Sensors 9 Armored Outdoor Industrial RBSx06 Sensors 10 Chapter 4 Common Messages 11 Common Messages 11 Message Protocol 11 Uplink Messages 11 Reset Message 0x00 12 Supervisory Message 0x01 13 Tamper M...

Страница 4: ...RaWAN Europe RBS301 DWS AU Indoor LoRaWAN Australia South America RBS306 DWS US Outdoor Industrial LoRaWAN North America South America RBS306 DWS EU Outdoor Industrial LoRaWAN Europe Documentation The...

Страница 5: ...ve a tab that does not pull out easily Loosen screws to remove the battery tab DO NOT REMOVE THE LID Hand tighten the lid screws to seal the case against moisture Do not overtighten the screws Quick S...

Страница 6: ...le shows complete when the device is successfully added Mounting the Sensor The window door sensor includes a sensor and a magnet that need line up 1 Use the included large adhesive pad to secure the...

Страница 7: ...ARING SENSOR Door Window Sensor User Guide 7 The tab will break away and send a tamper alert if the case is forcibly removed 5 Attach the magnet piece to the door so it aligns with the natch on the se...

Страница 8: ...t for high power radio technologies e g LoRaWAN Different battery types deplete over time with different voltage profiles a lithium battery maintains high voltage for the life of the battery with a ra...

Страница 9: ...NS AND INFORMATION Door Window Sensor User Guide 9 Mechanical Drawings The mechanical drawings provided in this section are for the main body of the sensor All dimensions use inches unless specified I...

Страница 10: ...HARDWARE SPECIFICATIONS AND INFORMATION 10 Door Window Sensor User Guide Armored Outdoor Industrial RBSx06 Sensors...

Страница 11: ...the specific format of a message type Packet Count 4 bits A sequential number starting at 0 for the first message sent from the sensor to the cloud It increments by one for each subsequent message Wh...

Страница 12: ...entifier sent as part of the reset message Door Window 0x01 1 Hardware version 2 3 Firmware version 4 5 Reset code Used for factory diagnostics Firmware Version The 16 bit firmware version is construc...

Страница 13: ...level is a two digit battery voltage For example if the battery voltage is 2 9V byte 2 would be 0x29 3 6 Extended sensor state 4 bytes Allows sensors with higher precision or multiple values to repor...

Страница 14: ...since the sensor is typically sleeping with the radio turned off For LoRaWAN devices a downlink can be received after any uplink within the receive window The following messages can be sent back to th...

Страница 15: ...Supervisory Period The general configuration command s supervisory period controls the time between supervisory messages as defined in the following table Bit 7 Bits 6 0 0 Period defined in hours 1 12...

Страница 16: ...aWAN only Port Number For LoRAWAN devices only Byte 0x01 of the advanced configuration command changes the uplink port per the LoRaWAN protocol The default port is 2 and a value of 0 in this field mea...

Страница 17: ...e to verify the that sensor received the downlink message received and it was considered valid The sensor replies to the downlink data with a 0xFF message downlink ACK with the payload shown in the fo...

Страница 18: ...a particular position open or closed before a message is sent An example of how this is would be used when monitoring a door to a refrigeration unit When the door is open or shut with say 1 minute no...

Страница 19: ...sensors FCC ID 2APNUCMABZ LoRaWAN RBS306 sensors This device contains FCC IAU792U13A16858 This device contains equipment certified under IC 125A 0055 Harmonized Commodity Description HS Code The Harm...

Отзывы: