PS9648 Power Supply User Guide

10

CommPlete Communications Server

Introduction

This chapter provides information needed to identify and fix problems with the PS9648 power supply
module. Problems can be observed on the CommPlete system’s front panel LEDs, the control PC’s screen,
or via audio alarm or alarm report. In addition, problems can be found when performing the Diagnostic
Tests documented elsewhere in the CommPlete Communications Server

 

User Guide

.

LED Indicators

The CommPlete Communication Server’s front panels contains the following indicators.

 

MR9600 controller LEDs.

 

Modem card LEDs. The number of LEDs on your modem card may vary, depending on the type of
modem card in your chassis. Please refer to your modem’s user guide for LED descriptions.

 

PS9648 power supply LED.

The PS9648 power supply LED is described below. Each of the other LED indicators is described in the
applicable manual.

Power Supply LED

This LED goes out if one of the PS9648 power supply outputs goes low or fails altogether. In normal
operation it is lit. The recovery procedure to be used depends on whether the CommPlete chassis has one
or two PS9648 power supplies installed.

Indication:

LED is on (either one or two PS9648s installed).

Meaning:

The power supply (or supplies) are operating properly.

Recovery:

No action required.

Indication:

LED is off (one PS9648 installed).

Meaning:

At least one of the outputs is low or out.

Recovery:

Turn off the power supply, remove it, and check the fuse. Replace the fuse if it is blown;
call Technical Support if the fuse is good (Chapter 5).

Indication:

LED is off (two PS9648s are installed).

Meaning:

At least one of the outputs is low or out. Power is being supplied by the second PS9648.

Recovery:

Turn off the PS9648 that has the LED off, and remove the PS9648.  If fuse is blown, it must
be replaced by a qualified service technician (Chapter 5); call Technical Support if the fuse
is good (Chapter 5).

Adjustment of the PS9648 Power Supply

For optimal operation of the CommPlete Communications Server, the 5 V output of the PS9648 power
supply should be adjusted to 5.1 VDC. The 5-volt test points are located on the back of the chassis between
the power supply fans.

Содержание PS9648

Страница 1: ...PS9648 Power Supply User Guide...

Страница 2: ...es the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi Tech Systems Inc to notify any person or organization of such revisions...

Страница 3: ...vironment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the in struction manual may cause harmful interference to radio communic...

Страница 4: ...iv CommPlete Communications Server...

Страница 5: ...ors 10 Power Supply LED 10 Adjustment of the PS9648 Power Supply 10 Important Safety Considerations 11 Fuse Replacement 11 Insertion and Removal of a Power Supply 12 Safety Disconnect Device 12 5 Warr...

Страница 6: ...vi CommPlete Communications Server...

Страница 7: ...CommPlete Communications Server 1 1 Introduction...

Страница 8: ...CC9648 chassis The outputs of the two power supplies are connected in parallel to the CC9648 chassis power bus If any of the outputs on either power supply fails or is too low the other power supply...

Страница 9: ...ed Warranty Two years Fuses 12 A 250 V fast blow non user replaceable Manual Organization Chapter 1 Introduction This chapter describes the PS9648 gives its technical specifications and provides a gui...

Страница 10: ......

Страница 11: ...CommPlete Communications Server 5 2 Installation...

Страница 12: ...ns be sure to use blanking plates to cover empty slots in the CC9648 chassis Installation Procedure 1 UnpackthePS9648assemblyfromitspackagingandsavethepackagingforpossiblefutureuse Performavisualinspe...

Страница 13: ...CommPlete Communications Server 7 3 Operation...

Страница 14: ...the international I on and O off symbols For the most reliable operation both power supplies should be turned on whenever the CommPlete Communications Server is operating Power Indicator The power in...

Страница 15: ...CommPlete Communications Server 9 4 Solving Problems...

Страница 16: ...low or fails altogether In normal operation it is lit The recovery procedure to be used depends on whether the CommPlete chassis has one or two PS9648 power supplies installed Indication LED is on ei...

Страница 17: ...ndPS9648supplywiththefirstPS9648powersupplyturnedoff KEYBOARD VIDEO CONFIG PORT ALARM T1 IN OUT MONITOR KEYBOARD VIDEO CONFIG PORT ALARM T1 IN OUT MONITOR KEYBOARD VIDEO CONFIG PORT ALARM T1 IN OUT MO...

Страница 18: ...mend that you insert the power supply slowly If the power supply is not replaced a cover plate must be installed Safety Disconnect Device The switches on the power supplies are not safety disconnect d...

Страница 19: ...CommPlete Communications Server 13 5 Warranty Service and Technical Support...

Страница 20: ...ortation prepaid MTS WILL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES AND UNDER NO CIRCUMSTANCES WILL ITS LIABILITY EXCEED THE PURCHASE PRICE FOR DEFECTIVE PRODUCTS Service If your technical support speci...

Страница 21: ..._______________________________________________ ____________________________________________________________________________ ___________________________________________________________________________...

Страница 22: ...nloading a File If you know the file name 1 FromtheMainMenu typeFtoaccesstheFilesMenu thentypeD 2 EnterthenameofthefileyouwishtodownloadfromtheBBS 3 Ifapasswordisrequired enterthepassword 4 AnswerYorN...

Страница 23: ...of the recipient or Sysop the subject and the message text Press ESC to finish then type S to save the message and exit To abort the message at any point leave any of the fields blank and press ENTER...

Страница 24: ...t the Multi Tech Fax Back Service Multi Tech s fax back service provides 24 hour access to sales marketing and technical literature for customers in the USA Dial 612 717 5888 follow the voice prompts...

Страница 25: ...s 2 fuse 3 10 I installation 6 Internet 2 18 L LED 10 M manual organization 3 Multi Tech BBS 16 O operating the PS9648 8 P power bus 2 power cords 12 power indicator 6 8 10 power switch 8 S safety 6 1...

Страница 26: ...PS9648 Power Supply User Guide 20 CommPlete Communications Server...

Страница 27: ......

Отзывы: