Features and Technical Specifications 

Data Interface 

Serial, Binary, Asynchronous

 

 

Data Rates 

Serial interface supports speeds up to56K  

Server-to-Client Data 
Rates 

56K speeds when accessing a server (actual speed depends on server capabilities 
and line conditions) 

Client-to-Server Data 
Rates 

Up to 48Kbps when accessing a V.92 server (actual speed depends on server 
capabilities and line conditions); otherwise, the same rates as client-to-client data 
rates apply (see Client-to-Client Data Rates).  

Client-to-Client Data 
Rates 

33600, 31200, 28800, 26400, 24000, 21600, 19200, 16800, 14400, 12000, 9600, 
7200, 4800, 2400, 1200, 0-300 bps 

Fax Rates 

33600, 31200, 28800, 26400, 24000, 21600, 19200, 16800, 14400, 12000, 9600, 
7200, 4800, 2400, 300 bps  

Modem Compatibility 

V.92, V.90, V.34, V.32bis, V.32, V.22bis, V.22, Bell 212A and 103/113, V.21, V.23, 
V.42bis, V.44 

Fax Compatibility 

ITU-T “Super” Group 3; Class 1.0, 2.0, 2.1; T.4; T.30; V.21; V.27ter; V.29; V.34; V.17; 

and TIA/EIA Class 1, 2; TR29.2 

Error Correction 

V.42  

Data Compression 

V.44, V.42bis 

 

Flow Control 

XON/XOFF; hardware (RTS/CTS) 

Transmit Level 

-13 dBm 

Environmental 

Temperature range -40

°

C to +85

°

Mechanical Dimensions 
& Weight 

4.3" w x 2.4" h x 0.94" d; 4.2 oz. 
(11 cm x 6.1 cm x 2.4 cm; 120 g) 

Command Buffer 

60 characters 

Other Features 

Global approvals in many countries for worldwide use 
Desktop or panel mounting 
Industrial chassis (a rugged, water-resistant, industrial chassis made of  aluminum) 
Automatic fallback to slower speeds in noisy line conditions and fall-forward to faster 

speeds as conditions improve 

Fully AT command compatible 
2-wire leased-line support 
Flash memory for easy updates 
Callback security; Remote configuration 
Caller ID (in U. S.) 
Autodial, redial, repeat dial, dial pauses; Pulse or tone dial and touch-tone dial 
Dial tone and busy signal detection for reliable call progress reporting 
Nonvolatile memory for storage of custom settings and two telephone numbers 
Call status display 
Auto parity and data rate selections 
On-screen displays for modem option parameters 

Manufacturing 
Information 

Trade Name:  

MultiModem  

 

Model Number:  

MT5634IND 

Registration Number: 

The embedded SocketModem MT5634SMI is the registered 
part of this product: AU7USA-25814-M5-E   

 

Ringer Equivalence: 

0.3B 

Modular Jack (USOC): 

RJ11

 

Certification 

EMC Safety Approvals:  

FCC Part 15 Class B – Emissions for U.S.A. and Canada 
EN55022 Class B – Emissions for EU countries. Needed for CE marking 
EN55024 – Immunity for EU countries. Needed for CE marking 
EN61000-6-2 – Immunity for industrial environments

 

Safety Certifications:  

UL60950-1 – U.S.A. and Canada Safety 
EN60950-1 – Safety for EU countries. Needed for CE marking 
GR1089 – Clause 4 NEBS Tested 

Reliability: 
 

Temperature Range: -40

°

C to +85

°

EN60068-2-6 – Vibration 10 to 500 Hz sine vibration 5g 
EN60068-2-30 – Temp/Humidity Damp Heat cycling  
EN60068-2-1 – Cold (-40

°

C) 

EN60068-2-2 – Dry Heat (+85

°

C) 

EN60068-2-14 – Change of Temperature (-40

°

C to +85

°

C) 

IEC 68-2-27 – Shock – 3 shocks/3mS duration 50g

 

Warranty 

5 years 

 

Содержание MultiModem IND MT5634IND

Страница 1: ...Data Fax Industrial Temperature Modem MT5634IND User Guide...

Страница 2: ...port listing warranty and descriptions of mounting bracket Patents This device is covered by one or more of the following patents 6 031 867 6 012 113 6 009 082 5 905 794 5 864 560 5 815 567 5 815 503...

Страница 3: ...anging the Setup Password 14 Changing the Remote Escape Character 14 Chapter 5 Callback Security 15 Changing the Setup Password 15 Turning Callback Security On and Off 15 Setting Callback Security Mes...

Страница 4: ...25 C ROHS HT TS Substance Concentration 26 Waste Electrical and Electronic Equipment 27 Other 27 Appendix C Multi Tech Warranty Statement and Product Repair 28 Warranty 28 Product Repair 28 Repair Pr...

Страница 5: ...line cord This product must be disconnected from the telephone network interface when servicing MultiModem Package Contents AC Powered Version One MT5634IND industrial data fax modem One mounting bra...

Страница 6: ...strial chassis a rugged water resistant industrial chassis made of aluminum Automatic fallback to slower speeds in noisy line conditions and fall forward to faster speeds as conditions improve Fully A...

Страница 7: ...other modem CD Carrier Detect This LED is lit when the modem detects a valid carrier signal from another modem It is on when the modem is communicating with the other modem and off when the link is br...

Страница 8: ...ust be configured as the originate modem and the other as the answer modem however it does not matter which is which You must enter these commands in your communication program s terminal window In th...

Страница 9: ...ctions for attaching the mounting bracket 1 Typically the modem is mounted against a flat surface with two mounting screws Drill the mounting holes at the desired location The mounting holes must sepa...

Страница 10: ...232 connector on the modem and plug the other end into a serial port connector on your computer such as COM1 or COM2 Phone Line Connection Plug one end of the phone cable into the MT5634IND LINE jack...

Страница 11: ...one of two country region configuration methods The Global Wizard AT Commands Using the Global Wizard The Global Wizard configuration utility isrecommendedfor computers running Windows 95 or newer 1...

Страница 12: ...ools icon You will be asked to choose your language The software automatically loads onto your PC PhoneTools PhoneTools is a data communications program included as part of your MultiModemIND purchase...

Страница 13: ...ech Systems Inc MT5634IND User Guide S000369B 13 Chapter 3 AT Commands S Registers and Result Codes AT commands and Fax commands for the MT5634IND are published in a separate Reference Guide included...

Страница 14: ...sword you should change the password Changing the Setup Password 1 Open a data communications program such as HyperTerminal or PhoneTools 2 In the terminal window type AT SMTSMODEM or AT Sxxxxxxxx if...

Страница 15: ...nds with OK if the setup password is correct and ERROR if it is wrong 3 To change the password type AT S xxxxxxxx where xxxxxxxx stands for the password and then press Enter The password can include a...

Страница 16: ...commands Example AT Z0 ATM0DT5551212 Up to 35 characters can be used The and characters are optional Number entry Enables a mobile caller to enter his current phone number for callback Direct connecti...

Страница 17: ...te the call You are allowed three attempts to enter the password after which you will be disconnected 8 If the password is valid the following message appears and the modems establish a working connec...

Страница 18: ...callback modem responds with the following message Password 3 Type a direct connection password press the key and then press ENTER You have three attempts or one minute to enter a valid password 4 If...

Страница 19: ...is on try moving the power supply to another outlet on the power strip Test that the outlet is live by plugging another device such as a lamp into it The modem or power supply may be defective If you...

Страница 20: ...ial port install the modem on it change the COM port setting in your software and try again The modem might have a problem beyond the scope of this user guide If you have another Multi Tech modem try...

Страница 21: ...d a poor connection because of line conditions or the problem might have originated on the other end of the line Try again Your ISP might have hung up on you because of lack of activity on your part o...

Страница 22: ...bps the remote modem might not use the same transmission or error correction standards as your modem Try connecting at a slower speed or disabling error correction With no error correction however li...

Страница 23: ...in memory when the modem is turned off and can be upgraded as new features are added Multi Tech s Flash Wizard can be downloaded from Multi Tech s FTP site and is available on the MT5634IND CD Use thi...

Страница 24: ...e designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and use...

Страница 25: ...his equipment is connected to the same line as other equipment may give rise to bell tinkle or noise and may also cause a false answer condition Should such problems occur the user should NOT contact...

Страница 26: ...n MII EIP 39 RoHS Multi Tech Systems Inc TS HS PB Hg CD CR6 PBB PBDE O O O O O O X O O O O O X O O O O O O O O O O O O O O O O O IC O O O O O O O O O O O O X O O O O O O O O O O O O O O O O O O O O O...

Страница 27: ...European Union The symbol shown below is on the product or on its packaging which indicates that this product must not be disposed of with other waste Instead it is the user s responsibility to dispo...

Страница 28: ...ti Tech product online at the following URL http www multitech com register Product Repair Repair Procedures for U S and Canadian Customers In the event that service is required products may be shippe...

Страница 29: ...Support department nearest you or email support multitech com When calling the U S please direct your questions regarding repair expediting receiving shipping billing etc to our Repair Accounting dep...

Страница 30: ...FCC Regulations 24 Features 6 Firmware Upgrade 23 Flash Upgrade 23 Flash Wizard 23 Front Panel 19 G Garbage Characters 22 Global Configuration 11 Global Wizard 11 I Indicators 19 Install Data Communic...

Страница 31: ...T5634IND User Guide S000369B 31 T Terminal Ready 7 Testing the Modem Self Test 19 Transmit Data 7 Troubleshooting 19 U Upgrade Firmware 23 W Warranty 28 Waste Electrical and Electronic Equipment WEEE...

Отзывы: