Multitech Dragonfly Nano MTQN-MNG3-B02 Скачать руководство пользователя страница 16

SAFETY INFORMATION

16

Dragonfly

Nano MTQN-MNG3-B02 Device Guide

General Safety

The device is designed for and intended to be used in fixed and mobile applications. Fixed means the device is
physically secured at one location and cannot be easily moved to another location. Mobile means the device is
used in other than fixed locations.

CAUTION:

Maintain a separation distance of at least 20 cm (8 inches) between the transmitter’s antenna and the

body of the user or nearby persons. The device is not designed for or intended to be used in portable applications
within 20 cm (8 inches) of the user’s body.

Attention:

Maintenir une distance d'au moins 20 cm (8 po) entre l'antenne du récepteur et le corps de l'utilisateur

ou à proximité de personnes. Le modem n'est pas conçu pour, ou destinés à être utilisés dans les applications
portables, moins de 20 cm du corps de l'utilisateur.

Interference with Pacemakers and Other Medical Devices

Potential Interference

Radio frequency energy (RF) from cellular devices can interact with some electronic devices. This is
electromagnetic interference (EMI). The FDA helped develop a detailed test method to measure EMI of implanted
cardiac pacemakers and defibrillators from cellular devices. This test method is part of the Association for the
Advancement of Medical Instrumentation (AAMI) standard. This standard allows manufacturers to ensure that
cardiac pacemakers and defibrillators are safe from cellular device EMI.

The FDA continues to monitor cellular devices for interactions with other medical devices. If harmful interference
occurs, the FDA will assess the interference and work to resolve the problem.

Precautions for pacemaker wearers

If EMI occurs, it could affect a pacemaker in one of three ways:

Stop the pacemaker from delivering the stimulating pulses that regulate the heart's rhythm.

Cause the pacemaker to deliver the pulses irregularly.

Cause the pacemaker to ignore the heart's own rhythm and deliver pulses at a fixed rate.

Based on current research, cellular devices do not pose a significant health problem for most pacemaker wearers.
However, people with pacemakers may want to take simple precautions to be sure that their device doesn't cause
a problem.

Keep the device on the opposite side of the body from the pacemaker to add extra distance between the
pacemaker and the device.

Avoid placing a turned-on device next to the pacemaker (for example, don’t carry the device in a shirt or
jacket pocket directly over the pacemaker).

Vehicle Safety

When using your device in a vehicle:

Do not use this device while driving.

Respect national regulations on the use of cellular devices in vehicles.

If incorrectly installed in a vehicle, operating the wireless device could interfere with the vehicle’s
electronics. To avoid such problems, use qualified personnel to install the device. The installer should verify
the vehicle electronics are protected from interference.

Using an alert device to operate a vehicle’s lights or horn is not permitted on public roads.

Содержание Dragonfly Nano MTQN-MNG3-B02

Страница 1: ...Dragonfly Nano MTQN MNG3 B02 Device Guide ...

Страница 2: ...RRANT THAT THE TRANSMISSION OF DATA BY A PRODUCT OVER A CELLULAR COMMUNICATIONS NETWORK WILL BE UNINTERRUPTED TIMELY SECURE OR ERROR FREE NOR DOES MULTITECH WARRANT ANY CONNECTION OR ACCESSIBILITY TO ANY CELLULAR COMMUNICATIONS NETWORK MULTITECH WILL HAVE NO LIABILITY FOR ANY LOSSES DAMAGES OBLIGATIONS PENALTIES DEFICIENCIES LIABILITIES COSTS OR EXPENSES INCLUDING WITHOUT LIMITATION REASONABLE ATT...

Страница 3: ...ng Conditions 11 Absolute Maximum Rating 11 DC Electrical Characteristics 12 Input Output Current Ratings 12 Power Draw 13 Chapter 4 Antennas 14 Antenna 14 Antenna Specifications 14 Chapter 5 Safety Information 15 Handling Precautions 15 Radio Frequency RF Safety 15 General Safety 16 Interference with Pacemakers and Other Medical Devices 16 Vehicle Safety 16 Device Maintenance 17 User Responsibili...

Страница 4: ... Substances 26 Information on HS TS Substances According to Chinese Standards in Chinese 27 Information on HS TS Substances According to Chinese Standards 28 Chapter 10 Using Connection Manager 29 Installing Connection Manager 29 Setting Up a Serial Device in Windows Device Manager 30 Connecting a Device 32 Uninstalling Connection Manager 33 Connection Manager User Interface 34 Main tab 34 Setting...

Страница 5: ...model specifications and developer information regarding the B02 version of MTQN S000713 Universal Developer Kit 2 0 Developer Guide Provides information for using the developer board with the MTQN S000610 Sara R4 USB Driver Installation Guide Provides instructions on how to install Windows USB driver N A Sara R4 N4 series AT Commands Manual Check radio and manual Provides AT commands and paramete...

Страница 6: ...MECHANICAL DRAWINGS 6 Dragonfly Nano MTQN MNG3 B02 Device Guide Chapter 2 Mechanical Drawings MTQN MNG3 B02 ...

Страница 7: ... Board to Board I O 1 x UART 1 x HS USB SMS Mobile Terminate Mobile Originate PDU Text mode LED Link Status solid registered for default setting use AT UGPIOC 16 2 see AT command guide for details and more options Physical Description Weight less than 0 3 oz 8 5g Dimensions 28 96mm x 32 51mm 1 14 x 1 28 inches Refer to Mechanical Drawings for details Connectors Antenna 1 surface mount U FL cellula...

Страница 8: ... be used with this product Recommended Parts Manufacturer Part Part Number PEM Penn Engineering Manufacturing Surface Mount Standoff SMTSO M3 6 RAF Electronic Hardware 6mm Hex Female Standoff 1251 3005 S 12 Zinc Note 1 We recommend grounding the standoffs to the main PCB for better performance Note 2 For other stacking heights refer to the Hirose DF17 Series 0 5mm Pitch Board to Board Connector Da...

Страница 9: ... GND Power Ground Connection 6 USB DATA 3 3 I O USB Data connection to cellular module 7 USB DATA USB Data connection to cellular module 8 VCC IN Power Power Input 9 RADIO_RX 3 3 O Cellular Radio UART Data Output 10 RADIO_DCD 3 3 O Cellular Radio UART DCD Output 11 RADIO_RI 3 3 O Cellular Radio UART RI Output 12 RADIO_CTS 3 3 O Cellular Radio UART CTS Output ...

Страница 10: ...9 RADIO_RTS 3 3 I Cellular Radio UART RTS Input 30 RADIO_DSR 3 3 O Cellular Radio UART DSR Output 31 RADIO_DTR 3 3 I Cellular Radio UART DTR Input 32 RADIO_TX 3 3 I Cellular Radio UART Data Input 33 VCC IN Power Power Input 34 LINK 3 3 4 2 see note O Radio Link Status LED Solid registered for default setting use AT UGPIOC 16 2 see AT command guide for details and more options 35 NRESET 3 3 4 2 see...

Страница 11: ...c 3 2 5 25 Absolute Maximum Rating Symbol Description Conditions Min Max Unit VCC Module supply voltage Input DC voltage at VCC pin 0 5 6 0 V GDI Generic digital interfaces Input DC voltage at Generic digital interfaces pins 0 5 6 5 V SIM SIM interface Input DC voltage at SIM digital interfaces pins 0 3 3 9 V ERS External reset signal Input DC voltage at RESET_N pin 0 5 4 3 V P_ANT Antenna power I...

Страница 12: ...signal input low level 0 1 155 Digital signal input high level 2 145 3 3 Output low level voltage for an I O pin 0 4 Output high level voltage for an I O pin 2 9 1 Guaranteed by characterization results not tested in production 2 Guaranteed by design not tested in production Input Output Current Ratings Output current draw all other output pins 1 mA ...

Страница 13: ...B only no Dev card GSM850 79 8 25 231 1 520 0 063 3 3 Volts with Unit In Dev Card External DC Supply used GSM850 20 4 10 N A N A N A 5 Volts with Unit In Dev Card LTE 15 6 7 176 796 0 426 5 Volts USB only no Dev card LTE 79 6 28 243 1 040 0 063 3 3 Volts with Unit In Dev Card External DC Supply used LTE 20 4 11 N A N A N A 1 Maximum Power The continuous current during maximum data rate with the ra...

Страница 14: ...a with SMA Male Connector Model Number GY115IE002 001 MultiTech ordering information Model Quantity ANLTE4 1HRA 1 ANLTE4 2HRA 2 ANLTE4 10HRA 10 ANLTE4 50HRA 50 Antenna Specifications Category Description Frequency Range 0 698 0 96 GHz 1 710 2 170 GHz 2 30 2 69 GHz VSWR 3 1 maximum Gain 2 06 dBi Impedance 50Ω nominal Radiation Omni directional Polarization Linear vertical ...

Страница 15: ...ne or diesel fuel pumps and before filling your vehicle with fuel Switch OFF your wireless device in hospitals and any other place where medical equipment may be in use Sécurité relative aux appareils à radiofréquence RF À cause du risque d interférences de radiofréquence RF il est important de respecter toutes les réglementations spéciales relatives aux équipements radio Suivez les conseils de sé...

Страница 16: ...efibrillators are safe from cellular device EMI The FDA continues to monitor cellular devices for interactions with other medical devices If harmful interference occurs the FDA will assess the interference and work to resolve the problem Precautions for pacemaker wearers If EMI occurs it could affect a pacemaker in one of three ways Stop the pacemaker from delivering the stimulating pulses that re...

Страница 17: ...s specifically approved for such use The device may cause sparks Sparks in explosive areas could cause explosion or fire and may result in property damage severe injury and or death Do not expose your device to any extreme environment where the temperature or humidity is high Such exposure could result in damage to the device or fire Do not expose the device to water rain or spilled beverages It i...

Страница 18: ...n Communications Flow The MTQN MNG3 B02 provides a full UART interface from the cellular radio to the user application Model B02 also provides a USB interface Note When the USB interface is used via the 40 pin connector VUSB_SELECT is 5V or the USB connector the serial interface to the radio will not function Pin 24 VUSB_SELECT must be pulled to 5V to enable the USB interface available through the...

Страница 19: ...e under Downloads on the product page of the website USB Cable Recommendations If your device has a USB connector to avoid enumeration or power issues Use a high speed USB cable that is as short as possible Use a well shielded cable with at least 24 AWG wire pair for power ground and 28 AWG wire pair for data lines If possible use a USB port that connects directly to the motherboard rather than a ...

Страница 20: ...ROFF or Hold the NRESET signal pin 35 low for at least 1 second To verify that your device is powered down monitor the 1V8_MON signal pin 27 When it goes low the device is powered down Note Signal 1V8_MON operates at 3 318 V not 1 8V Note Note AT CPWROFF will not take more than 40s Configuring u blox Cellular Radio This MNG3 device uses a cellular radio that can operate on different carrier networ...

Страница 21: ...ot have a network defined yet and must set one To set or switch carrier networks 1 Deregister the module from the network or perform an AT CFUN 0 cycle AT CFUN 0 2 Set the carrier network refer to the list of UMNOPROF values To Vodafone AT UMNOPROF 19 To Standard Europe AT UMNOPROF 100 3 Reboot the module in order to apply the new configuration AT CFUN 15 If the APN is known and will not change We...

Страница 22: ...river Installation For the Windows USB driver refer to the SARA R4 USB Driver Installation Guide on the product page of the Multitech website The driver is located under the Downloads section of the product page For the Linux USB driver if your Linux OS does not automatically detect your device you may need to execute a script This script adds the MTQN vendor ID and product ID to the USB serial dr...

Страница 23: ...ion The MultiTech model identification allows the carrier to verify the modem as one of its approved models This information is located on the modem s label below the bar code Example Labels Note Actual labels vary depending on the regulatory approval markings and content This device complies with EU rules RED Compliance Operation is subject to the following two conditions 1 This device may not ca...

Страница 24: ...irective 2011 65 EU on the restriction of the use of certain hazardous substances in electrical and electronic equipment and Council Directive 2014 53 EU on radio equipment and telecommunications terminal equipment and the mutual recognition of their conformity MultiTech declares that this device is in compliance with the essential requirements and other relevant provisions of Directive 2014 53 EU...

Страница 25: ... obliged to finance the costs of recovery from municipal collection points reuse and recycling of specified percentages per the WEEE requirements Instructions for Disposal of WEEE by Users in the European Union The symbol shown below is on the product or on its packaging which indicates that this product must not be disposed of with other waste Instead it is the user s responsibility to dispose of...

Страница 26: ...thalate DEHP 1000 ppm Benzyl butyl phthalate BBP 1000 ppm Dibutyl phthalate DBP 1000 ppm Diisobutyl phthalate DIBP 1000 ppm Environmental considerations Moisture Sensitivity Level MSL 1 Maximum Soldering temperature 260C in SMT reflow oven 1 Lead usage in some components is exempted by the following RoHS annex therefore higher lead concentration would be found in some modules 1000 PPM Resistors co...

Страница 27: ...息 有 有害 害 有 有毒 毒物 物质 质 元 元素 素 成 成分 分名 名称 称 铅 铅 PB 汞 汞 Hg 镉 镉 CD 六 六价 价铬 铬 CR6 多 多溴 溴联 联苯 苯 PBB 多 多溴 溴二 二苯 苯醚 醚 PBDE 印刷电路板 O O O O O O 电阻器 X O O O O O 电容器 X O O O O O 铁氧体磁环 O O O O O O 继电器 光学部件 O O O O O O ICs O O O O O O 二极管 晶体管 O O O O O O 振荡器和晶振 X O O O O O 调节器 O O O O O O 电压传感器 O O O O O O 变压器 O O O O O O 扬声器 O O O O O O 连接器 O O O O O O LEDs O O O O O O 螺丝 螺母以及其它五金件 X O O O O O 交流 直流电源 O O O O O...

Страница 28: ...ted Biphenyl PBB Polybrominat ed Diphenyl Ether PBDE Printed Circuit Boards O O O O O O Resistors X O O O O O Capacitors X O O O O O Ferrite Beads O O O O O O Relays Opticals O O O O O O ICs O O O O O O Diodes Transistors O O O O O O Oscillators and Crystals X O O O O O Regulator O O O O O O Voltage Sensor O O O O O O Transformer O O O O O O Speaker O O O O O O Connectors O O O O O O LEDs O O O O ...

Страница 29: ...he appropriate drivers are installed can cause the connection to fail To install Connection Manager and the device drivers 1 Go to https www multitech com support connection manager 2 Click Connection Manager 3 Open or unzip the Connection Manager file and run the installer msi file 4 In the MultiTech Connection Manager Setup Wizard read the end user license agreement and check I accept the terms ...

Страница 30: ...ur computer if prompted by Windows If using a USB device you can connect the device to the carrier s network with Connection Manager Refer to Connecting a Device If using a serial device you need to set up the device in Windows Device Manager before connecting the device Refer to Setting Up a Serial Device in Windows Device Manager Note The L6G1 radio establishes a connection automatically as soon...

Страница 31: ...ecting another model may cause your device to work incorrectly or fail f Select your COM port then click Next g Click Finish h Go to Device Manager Modems and confirm that the device is added 6 To verify that the device is set up correctly query the device a Go to Device Manager Modems right click Standard 33600 bps Modem and select Properties b On the Diagnostics tab click Query Modem Note The de...

Страница 32: ...c pings to a host check Enable keep alive and enter the IP address or host name to ping in the Host to ping box For example you can enter the host name google com or IP address 8 8 8 8 If the keep alive check fails Connection Manager automatically reconnects When the keep alive feature is enabled the Connection Manager s Main tab displays the keep alive check status and when the last ping response...

Страница 33: ... strength percentage and bars The statistics on connection speeds and traffic are available only during a current connection session Note For serial modems the signal strength is available only when the device is not connected to the carrier s network When connection to the network is established the last signal strength value is displayed View the details for the current connection on the Details...

Страница 34: ... following Status of device connection Searching Connecting Connected Disconnecting or Disconnected The action button which changes according to the current device connection status Detect Connect or Disconnect Signal strength bars and percentage indicator only when connection to the carrier s network is established Note The signal strength is displayed for a serial device only when the device is ...

Страница 35: ... Connection tab The Connection tab displays the following The carrier provided connection settings The Enable keep alive check box Check this box to monitor connectivity to the Internet Check Enable keep alive check and enter the IP address or host name to ping in the Host to ping box Connection Monitor will send periodic pings to the host If the keep alive feature fails Connection Manager will au...

Страница 36: ...connected to the PC and that the correct USB cable is in use Connection Manager is not working and a device connected to the computer is not detected Connection Manager cannot detect a connected device because the required drivers are not installed The most likely cause is that Install the modem drivers was not checked during the installation Uninstall and re install Connection Manager During the ...

Страница 37: ...tab 34 overview 29 Settings tab 34 Terminal tab 34 troubleshooting 36 uninstalling 33 D device connecting to carrier s network with Connection Manager 32 device drivers installation for use with Connection Manager 29 documentation 5 drawings 6 E electrical characteristics 11 H hazardous substances 26 I install SIM card 18 L labels 23 M mounting hardware 8 O operating conditions 11 P pin connector ...