background image

MultiConnect

®

 Conduit™ IP67 Base Station  

MTCDTIP   Installation Guide

 

 

 

Warning and 

 Caution

 

Warning and Caution symbols mean potential danger. You are in a situation that could cause bodily injury. Before working on any equipment, be aware 
of hazards in the installation area and be knowledgeable about electrical circuitry. Be familiar with standard practices for preventing accidents.   
 
For translations of key cautions and warnings, go to

 

http://www.multitech.net/developer/basestation. 

 

WARNING:

 Only trained and qualified personnel should install, replace, or service this equipment. Installation must comply with local 

and national electrical codes. 

 

When installing or replacing the unit, the ground connection must always be made first and disconnected last.

 

 

Do not work on the system or connect or disconnect cables during periods of lightning activity.

 

 

This device is not designed or approved to be used in any Hazardous Locations. Do not install or operate device if area is known to be an explosive 
environment.

 

 

Externally ground this equipment using a customer-supplied ground wire before applying power. Contact an electrician if you are uncertain that 
suitable grounding is available. Refer to 

Installing the Ground Wire

 instructions.

 

 

All wall mounting installations are subject to the acceptance of local jurisdiction.

 

 

Do not locate antenna near overhead power lines or other electric light or power circuits, or where it can come into contact with such circuits. When 
installing the antenna, take extreme care not to come into contact with such circuits, because they may cause serious injury or death. For proper 
installation and grounding of the antenna, please refer to national and local codes.

 

 

CAUTION:  

 

Power over Ethernet (PoE) Certification does not apply or extend to voltages outside of standard PoE range. Any PoE voltages beyond 0Vdc to 
60Vdc have not been evaluated by UL or MULTITECH. Nominal PoE voltage is 48Vdc. The end user supplies the PoE cable. This cable must be 
suitable for outdoor location. This is an 802.3at Type 2 device.  Power input is 25W from standard 802.3at PoE input. 

 

 

Ethernet port is not designed to be connected to a public Telecommunication (PSTN) or any other connection other than IEEE 802.3-2012 power 
over Ethernet devices. 

 

 

Do not remove product labels.

  

WARNING!

 

HOT SURFACE DO NOT TOUCH  

Note:  This symbol is included on the serial label. UL evaluated this device to a safety and outdoor certification temperature of -30c to +85c. 
Operating temperature is -30c to +65c. 
 

Part: 82101653L                                                                                                                                                       Copyright © 2017 Multi-Tech Systems, Inc. All rights  reserved. 

MultiConnect Conduit IP67 Base Station 

Use the MultiConnect Conduit IP67 Base Station (MTCDTIP) to deploy Conduit gateways in the field.   

CAUTION:

 Read installation instructions and safety information before starting Base Station installation.  

Do not connect power until directed to do so.  

 Item

 

 Description

 

 Quantity

 

 

 

 Item

 

 Description

 

 Quantity

 

 MTCDTIP Base Station 

 Hose clamps 

 Mounting bracket 

 ¼ x 1 inch screws and anchors 

4 each 

 M6 x 15mm screws, washers, and split washers  4 each 

 Installation Guide 

 M5 x 10mm screws, washers, and split washers  4 each  

 

 

 

If you do not install the accessory kit when you install the Base Station, cover the LoRa connector to ensure it remains dry. 

Package Contents  

SIM Card Installation 

If your SIM card was not pre-installed, follow these steps to install a SIM card in your device: 

 

WARNING:

  

If you connected power to the device, disconnect it before continuing.  

Requirements 

 

P2 Philips screwdriver 

 

 

Mini SIM Card; MultiTech recommends using an industrial-grade mini SIM card suitable for high temperatures

   

Installing SIM Card 

1. 

Remove the cover by removing the 14 screws as shown in Figure 1. 

 

2. 

Remove the Conduit from the Base Station by removing the 2 screws as shown in  
Figure 2.

 

3. 

At the front of the Conduit housing, remove the screw that secures the nameplate to the 
Conduit and remove the nameplate as shown in Figure 3.

 

4. 

Locate the SIM card holder in the upper right corner of the opening. Gently push the SIM 
card into holder face up with the cut corner to the right and the SIM contacts  
facing toward the Conduit’s interior as shown in Figure 3.

 

5. 

Reattach the MultiTech nameplate to the Conduit using the same screw removed in  
Step 3.

 

6. 

Reattach the Conduit to the Base Station using the 2 screws removed in Step 2.

 

7. 

Reattach the cover.

 

a. 

Finger-tighten the 14 screws removed from the cover in Step 1. 

 

b. 

Tighten all 14 screws in the order shown in Figure 4, starting with number 1. Tighten 
all screws to a torque specification of 5.20-6.94 lbf-in (6-8 kgf-cm) to ensure the product retains its IP67 rating.

 

Figure 1

 

 

Note:

  Antennas, cables, and a lightning arrestor are part of a separate accessory kit. 

Connector Locations 

 

 

           Top View

 

 

 

         

Bottom View  

 

 

    Back View 

Содержание Conduit

Страница 1: ...WARNING HOT SURFACE DO NOT TOUCH Note This symbol is included on the serial label UL evaluated this device to a safety and outdoor certification temperature of 30c to 85c Operating temperature is 30c to 65c Part 82101653L Copyright 2017 Multi Tech Systems Inc All rights reserved MultiConnect Conduit IP67 Base Station Use the MultiConnect Conduit IP67 Base Station MTCDTIP to deploy Conduit gateways...

Страница 2: ...al information or contact a licensed electrician for assistance Additional Information For Base Station dimension drawings MultiConnect Conduit regulatory information and instructions for using the MultiConnect Conduit go to www multitech net developer products conduit Regulatory Information This device complies with Part 15 of the FCC rules and with ICES 003 of Industry Canada for a Class A digit...

Страница 3: ...ption Quantity 1 Lightning Arrestor 1 4 5 ft Antenna Cable 1 2 LoRa Antenna 1 5 Antenna Bracket 1 3 4G Antenna 2 6 Installation Guide 1 NOTE The lightning arrestor comes with a bracket which is not needed Attaching Accessories for a Pole Mounted Base Station After mounting the Base Station on the pole 1 Attach the antenna mounting bracket to the LoRa antenna 2 Mount the antenna bracket to the pole...

Страница 4: ... bracket to the LoRa antenna 2 Mount the antenna bracket to the wall 3 Attach the lightning arrestor to LoRa antenna 4 Attach the antenna cable to the lightning arrestor 5 Attach the cable to the LoRa connector at the top of the Base Station 6 Attach the 4G antennas to the Cell and Aux connectors on the Base Station 7 Attach the Ethernet cable not provided to the device to supply power and Etherne...

Отзывы: