background image

MULTICONNECT CONDUIT AP MTCAP USER GUIDE FOR SPRINT

2

MultiConnect

®

Conduit

TM

AP MTCAP User Guide for Sprint

MultiConnect Conduit AP MTCAP User Guide for Sprint

MTCAP-LSP3-xx

Part Number: S000704, Version 1.0

Copyright

This publication may not be reproduced, in whole or in part, without the specific and express prior written permission signed by an executive officer of
Multi-Tech Systems, Inc. All rights reserved.

Copyright © 2018 by Multi-Tech Systems, Inc.

Multi-Tech Systems, Inc. makes no representations or warranties, whether express, implied or by estoppels, with respect to the content, information,
material and recommendations herein and specifically disclaims any implied warranties of merchantability, fitness for any particular purpose and non-
infringement.

Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of
Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.

Trademarks and Registered Trademarks

MultiTech, and the MultiTech logo, DeviceHQ, and MultiConnect are registered trademarks and Conduit is a trademark of Multi-Tech Systems, Inc. All other
products and technologies are the trademarks or registered trademarks of their respective holders.

Legal Notices

The MultiTech products are not designed, manufactured or intended for use, and should not be used, or sold or re-sold for use, in connection with
applications requiring fail-safe performance or in applications where the failure of the products would reasonably be expected to result in personal injury or
death, significant property damage, or serious physical or environmental damage. Examples of such use include life support machines or other life
preserving medical devices or systems, air traffic control or aircraft navigation or communications systems, control equipment for nuclear facilities, or
missile, nuclear, biological or chemical weapons or other military applications (“Restricted Applications”). Use of the products in such Restricted
Applications is at the user’s sole risk and liability.

MULTITECH DOES NOT WARRANT THAT THE TRANSMISSION OF DATA BY A PRODUCT OVER A CELLULAR COMMUNICATIONS NETWORK WILL BE
UNINTERRUPTED, TIMELY, SECURE OR ERROR FREE, NOR DOES MULTITECH WARRANT ANY CONNECTION OR ACCESSIBILITY TO ANY CELLULAR
COMMUNICATIONS NETWORK. MULTITECH WILL HAVE NO LIABILITY FOR ANY LOSSES, DAMAGES, OBLIGATIONS, PENALTIES, DEFICIENCIES, LIABILITIES,
COSTS OR EXPENSES (INCLUDING WITHOUT LIMITATION REASONABLE ATTORNEYS FEES) RELATED TO TEMPORARY INABILITY TO ACCESS A CELLULAR
COMMUNICATIONS NETWORK USING THE PRODUCTS.

The MultiTech products and the final application of the MultiTech products should be thoroughly tested to ensure the functionality of the MultiTech
products as used in the final application. The designer, manufacturer and reseller has the sole responsibility of ensuring that any end user product into
which the MultiTech product is integrated operates as intended and meets its requirements or the requirements of its direct or indirect customers.
MultiTech has no responsibility whatsoever for the integration, configuration, testing, validation, verification, installation, upgrade, support or maintenance
of such end user product, or for any liabilities, damages, costs or expenses associated therewith, except to the extent agreed upon in a signed written
document. To the extent MultiTech provides any comments or suggested changes related to the application of its products, such comments or suggested
changes is performed only as a courtesy and without any representation or warranty whatsoever.

Contacting MultiTech

Knowledge Base

The Knowledge Base provides immediate access to support information and resolutions for all MultiTech products. Visit

http://www.multitech.com/kb.go

.

Support Portal

To create an account and submit a support case directly to our technical support team, visit:

https://support.multitech.com

.

Support

Business Hours: M-F, 8am to 5pm CT

Country

By Email

By Phone

Europe, Middle East, Africa:

[email protected]

+(44) 118 959 7774

U.S., Canada, all others:

[email protected]

(800) 972-2439 or (763) 717-5863

Warranty

To read the warranty statement for your product, visit

www.multitech.com/warranty.go

. For other warranty options, visit

www.multitech.com/es.go

.

World Headquarters

Multi-Tech Systems, Inc.

2205 Woodale Drive, Mounds View, MN 55112

Phone: (800) 328-9717 or (763) 785-3500

Fax (763) 785-9874

Содержание Conduit AP MTCAP LSP3-915-001L

Страница 1: ...MultiConnect ConduitTM AP MTCAP User Guide for Sprint ...

Страница 2: ...WARRANT THAT THE TRANSMISSION OF DATA BY A PRODUCT OVER A CELLULAR COMMUNICATIONS NETWORK WILL BE UNINTERRUPTED TIMELY SECURE OR ERROR FREE NOR DOES MULTITECH WARRANT ANY CONNECTION OR ACCESSIBILITY TO ANY CELLULAR COMMUNICATIONS NETWORK MULTITECH WILL HAVE NO LIABILITY FOR ANY LOSSES DAMAGES OBLIGATIONS PENALTIES DEFICIENCIES LIABILITIES COSTS OR EXPENSES INCLUDING WITHOUT LIMITATION REASONABLE A...

Страница 3: ...pply Caution 11 Ethernet Ports 11 Ports Ethernet 11 Lithium Battery 11 General Safety 11 Handling Precautions 12 Radio Frequency RF Safety 12 Sécurité relative aux appareils à radiofréquence RF 12 Interference with Pacemakers and Other Medical Devices 13 Potential interference 13 Precautions for pacemaker wearers 13 Device Maintenance 13 UL Notice 14 Spécifications UL 14 User Responsibility 14 Cha...

Страница 4: ...etermining Location for the MTCAP 23 Mounting the MTCAP 24 Chapter 8 Regulatory Information 26 47 CFR Part 15 Regulation Class B Devices 26 FCC Interference Notice 26 Industry Canada Class B Notice 26 Industry Canada 27 Waste Electrical and Electronic Equipment Statement 27 WEEE Directive 27 Instructions for Disposal of WEEE by Users in the European Union 27 REACH Statement 27 Registration of Subs...

Страница 5: ...lete product code may end in Rx where R is revision and x is the revision number For example MTCAP LSP 915 001L R1 Package Contents Your device ships with the following 1 MTCAP 1 5 Volt 2 5 Amp Power supply 1 RJ45 Ethernet cable 1 Quick Start Important Contact MultiTech Systems if a replacement power supply is needed Using a different power supply may damage the device and voids the warranty Docum...

Страница 6: ...ries AT Commands Reference Guide For LSP3 devices lists AT Commands and parameters used to communicate with your device 80490ST10778A Rev 4 Related Documentation This manual provides the basics for getting started with mLinux or AEP For addition information visit our developer site at http multitech net and select Software mLinux ...

Страница 7: ...SPECIFICATIONS AND HARDWARE INFORMATION MultiConnect ConduitTM AP MTCAP User Guide for Sprint 7 Chapter 2 Specifications and Hardware Information Dimensions ...

Страница 8: ... to Mechanical Drawings for Dimensions Chassis Type PC ABS Environment Operating Temperature1 10 C to 65 C Storage Temperature 40 C to 85 C Humidity 20 90 RH non condensing Power Requirements Operating Voltage 5Vdc 1 4A Certifications and Compliance EMC and Radio Compliance FCC Part 15 Class B Cellular Radio FCC Part 22H 24E 27 90 RSS 130 132 133 139 LoRa Radio IC RSS 237 FCC 15 247 2018 FCC 15 10...

Страница 9: ... Device for details WPS Reserved for future use SIM Cellular models only SIM slot Refer to Installing SIM Card for details LEDs STATUS Blinks when operating system is fully loaded LORA Lights when LoRa software is active CELL Cellular models only Lights when there is power to the radio Blinks when the SIM is registered with the carrier WIFI Reserved for future use Ethernet Link Left LED on the Eth...

Страница 10: ...details on username and password requirements Note The device reboots when restoring settings Power Measurements MTCAP LSP3 915 Note Multi Tech Systems Inc recommends that you incorporate a 10 buffer into the power source when determining product load Maximum Power The continuous current during maximum data rate with the radio transmitter at maximum power Tx Pulse The average peak current during a...

Страница 11: ...ime may be incorrect Battery is not user replaceable If the battery fails the device must be sent back to MultiTech Systems for battery replacement Lithium cells and batteries are subject to the Provisions for International Transportation Multi Tech Systems Inc confirms that the Lithium batteries used in the MultiTech product s referenced in this manual comply with Special Provision 188 of the UN ...

Страница 12: ...suspension or denial of cellular services to the offender legal action or both Switch OFF your wireless device when around gasoline or diesel fuel pumps and before filling your vehicle with fuel Switch OFF your wireless device in hospitals and any other place where medical equipment may be in use Sécurité relative aux appareils à radiofréquence RF À cause du risque d interférences de radiofréquenc...

Страница 13: ...use a problem Keep the device on the opposite side of the body from the pacemaker to add extra distance between the pacemaker and the device Avoid placing a turned on device next to the pacemaker for example don t carry the device in a shirt or jacket pocket directly over the pacemaker Device Maintenance Do not attempt to disassemble the device There are no user serviceable parts inside When maint...

Страница 14: ...UL UL Certification does not apply or extend to use in vehicles or outdoor applications or in ambient above 40 C Spécifications UL Listé UL à 40 C limité par l alimentation La certification UL ne s applique pas ou ne s étend pas à des températures dépassant 40 C et le produit n a pas été évalué par UL pour une température ambiante dépassant 40 C UL a évalué cet appareil pour une utilisation en zon...

Страница 15: ... of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation The label shown is not the actual size 1 MultiTech Model Identification 2 MultiTech Ordering Part Number 3 IMEI Number 4 Device Node Number 5 UUID Example 915 Models ...

Страница 16: ...ard completely into the SIM holder Removing a SIM Card To remove the SIM card push the SIM card in The device ejects the SIM card Cabling the Device To cable the device 1 Connect the Ethernet cable to the Ethernet port on the device and to your computer 2 Connect the power supply to the MTCAP s power jack and plug it into an electrical outlet When the operating system is fully loaded the STATUS LE...

Страница 17: ... have root privileges As a result many commands may not work unless you use sudo for super user permissions To use sudo either execute sudo command or start the root shell sudo s Then enter the mtadm password The prompt changes to mtcap home mtadm For tips on using sudo go to http www multitech net developer software mlinux using mlinux log in as an admin post production The following commands req...

Страница 18: ...dify etc network interfaces as follows a Add gateway 192 168 2 254 beneath the netmask line where 192 168 2 254 is the IP address of your network router b To apply changes either reboot the device or issue ifdown eth0 ifup eth0 Note You will lose your SSH session by doing this c Test Internet access with ping 8 8 8 8 Configuring the Cellular Connection To establish a cellular data link you must co...

Страница 19: ...ts 7 errors 0 dropped 0 overruns 0 frame 0 TX packets 8 errors 0 dropped 0 overruns 0 carrier 0 collisions 0 txqueuelen 3 RX bytes 106 106 0 B TX bytes 145 145 0 B Additionally you can view the pppd logs in var log messages to see the modem dialing and assigned IP address or errors if the connection was unsuccessful To Stop a PPP Connection send SIGTERM to pppd which causes it to hang up and exit ...

Страница 20: ...network Note We recommend that you allow Sprint to set the correct APN values automatically via OTA Here s how to check your APN and PDP context 1 Allow the system to set the APN value with Sprint s Over The Air update OMADM Do not attempt to set the APN on your own 2 Check the APN value using this command AT DEBUG Example output Note The output includes the data APN after APN internet Record this...

Страница 21: ...CGDCONT CGDCONT 1 IP otasn 0 0 0 0 CGDCONT 3 IPV4V6 n ispsn 0 0 0 0 CGDCONT 5 IPV4V6 ims 0 0 0 0 4 For data connection attempts use the PDP context in the AT CGDCONT response matching the APN indicated in AT DEBUG response For example 1 cc m2m ispsn appears in AT DEBUG output and in PDP context 2 output as illustrated Therefore in the first example PDP context 2 would be used for data connection e...

Страница 22: ...lic Choose from 0 Private MTS 1 Public LoRaWAN or 2 Private LoRaWAN Private Options use SyncWord 0 12 vs Public SyncWord 0 34 network joinDelay Set to desired Join Delay default 5 seconds 4 Restart the network server etc init d lora network server restart 5 Start mosquitto client mosquitto_sub t lora v For advanced LoRa settings go to http www multitech net developer software lora conduit mlinux l...

Страница 23: ...P as high as possible such as near the top of a wall Avoid obstructions Thick walls and reflective surfaces such as metal weaken the signal between the MTCAP and other devices Note the LoRa antenna location in the following image The signal will be strongest radiating from that side of the device The LoRa antenna is 31 2 mm long The LoRa antenna is an omni directional antenna but for best results ...

Страница 24: ...nt Mounting the MTCAP 1 Determine where you want to mount the device 2 Mark where you want the screws to go 3 Drill holes for the screws and insert anchors 4 Place the mounting bracket and secure it with screws 5 Attach the device to the bracket and rotate to lock into place ...

Страница 25: ...MOUNTING THE DEVICE MultiConnect ConduitTM AP MTCAP User Guide for Sprint 25 ...

Страница 26: ...echnician for help Warning Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC Interference Notice This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any inte...

Страница 27: ...EEE requirements Instructions for Disposal of WEEE by Users in the European Union The symbol shown below is on the product or on its packaging which indicates that this product must not be disposed of with other waste Instead it is the user s responsibility to dispose of their waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic e...

Страница 28: ...a is controlled as part of a formal quality system and will be made available upon request Restriction of the Use of Hazardous Substances RoHS Multi Tech Systems Inc Certificate of Compliance 2011 65 EU Multi Tech Systems Inc confirms that its embedded products comply with the chemical concentration limitations set forth in the directive 2011 65 EU of the European Parliament Restriction of the use...

Страница 29: ...romi nated Biphenyl PBB Polybrominat ed Diphenyl Ether PBDE Printed Circuit Boards O O O O O O Resistors X O O O O O Capacitors X O O O O O Ferrite Beads O O O O O O Relays Opticals O O O O O O ICs O O O O O O Diodes Transistors O O O O O O Oscillators and Crystals X O O O O O Regulator O O O O O O Voltage Sensor O O O O O O Transformer O O O O O O Speaker O O O O O O Connectors O O O O O O LEDs O...

Страница 30: ...水平方面的信息 有 有害 害 有 有毒 毒物 物质 质 元 元素 素 成 成分 分名 名称 称 铅 铅 PB 汞 汞 Hg 镉 镉 CD 六 六价 价铬 铬 CR6 多 多溴 溴联 联苯 苯 PBB 多 多溴 溴二 二苯 苯醚 醚 PBDE 印刷电路板 O O O O O O 电阻器 X O O O O O 电容器 X O O O O O 铁氧体磁环 O O O O O O 继电器 光学部件 O O O O O O ICs O O O O O O 二极管 晶体管 O O O O O O 振荡器和晶振 X O O O O O 调节器 O O O O O O 电压传感器 O O O O O O 变压器 O O O O O O 扬声器 O O O O O O 连接器 O O O O O O LEDs O O O O O O 螺丝 螺母以及其它五金件 X O O O O O 交流 直流电源 O O...

Страница 31: ... Ethernet 9 16 configuration 18 Ethernet ports 11 F FCC Notice Class B 26 G getting started 17 H hazardous substances 28 I Industry Canada Class B 26 interférence des radiofréquences 12 IP address 18 L labels 15 LEDs 9 lithium battery 11 LoRa setup 21 LORA LED 9 M maintenance 13 mLinux 17 modem safety 11 mounting device 23 N network settings 18 P package contents 5 Ports Ethernet 11 power jack 9 p...

Страница 32: ...ide for Sprint S safety 11 modem 11 RF interference 12 SIM card remove 16 SIM installation 16 specifications 8 static 12 STATUS LED 9 sécurité 11 interférences RF 12 T terminal interface 17 time 17 transmission 8 U user responsibility 14 W WIFI LED 9 ...

Отзывы: