background image

Read complete instructions prior to installation 
and operation of the unit. 

WARNING :

 Risk of electric shock.

SAFETY PRECAUTION

!

       All safety related codifications, symbols and instructions that 
appear in this operating manual or on the equipment must be 
strictly followed to ensure the safety of the operating personnel 
as well as the instrument. 

      If all the equipment is not handled in a manner specified by
 the manufacturer, it might impair the protection provided by the 
equipment.

UTC-221P

Input Types

PV

 = Process Value

SV

 = Set Value

Resolution

Indication
Accuracy

Input  

Range

TEMPERATURE CONTROLLER

0 to 600°C, 

0 to 1200°C, 

-99 to 400°C, 

-99.9 to 400.0°C, 

PT-100 

PT.1 

J,K,PT-100 = 1°C

±1% of FSD ± 1°C

PT.1 = 0.1°C

POWER SUPPLY:

ENVIRONMENT CONDITION:

Display

Heating

Size 

Keys

Cooling

Panel Cutout

Power 
Consuption
(VA Rating)

Relative Humidity

Protection Level

(As per request)

Relay

Output Signal

 Supply 
 Voltage

 Operating Temp.

Relay Type

Rating

Upper: 4 digit, 7 segment, 0.70” Red

1) PID control with Auto-Tuning

Lower: 4 digit, 7 segment, 0.50” Green

2) ON-OFF control

72 (H) x 72 (W) x 85 (D) mm

100 to 270V AC, 50-60Hz

0°C to 55°C

UP to 95% RH 
(non-condensing)

IP-65 (Front side) As per IS/IEC
60529 : 2001

1 Nos

12V DC, 30mA DC 
(On-Off condition)

Relay parallel to SSR

1C/O (NO-C-NC)

10A, 230V AC / 28V DC

SET, INC, DEC, ENT

ON-OFF control

68 (H) x 68 (W) mm

4VA @ 230V AC MAX

Relay Output

SSR Drive Output

TECHNICAL SPECIFICATION

KEY OPERATION

72

85

68

68

3

MECHANICAL INSTALLATION

TERMINAL CONNECTION

72

Outline Dimension (mm)

Panel Cutout 
Dimension (mm)

To enter in parameter setting

For start/stop PID auto tuning

Press 
6 sec

Press 3 sec

+

To go in factory setting mode

PRESS KEY

FUNCTION

OPERATOR MODE

PARAMETER SETTING MODE

To set parameter value

To increment parameter value.

To decrement parameter value.

Set parameter to be save & exit. 

WARNING GUIDELINES

WARNING : Risk of electric shock.

 1. To prevent the risk of electric shock, power supply to the 
    equipment must be kept OFF while doing the wiring 
     arrangement. Do not touch the terminals while power is 
     being supplied.  

 2. To reduce electro magnetic interference, use wire with 
    adequate rating and twists of the same of equal size shall 
     be made with shortest connection.            

 3. Cable used for connection to power source, must have a 
     cross section of 1mm or greater. These wires should have 
     insulations capacity made of at least 1.5kV.      

 4. When extending the thermocouple lead wires, always use
     thermocouple compensation wires for wiring for the RTD
     type, use a wiring material with a small lead resistance
     (5    max per line) and no resistance differentials among 
     three wires should be present.    

 5. A better anti-noise effect can be expected by using 
     standard power supply cable for the instrument.         

Ω

INSTALLATION GUIDELINES

1. This equipment, being built-in-type, normally becomes a 
    part of main control panel and in such case the terminals
    do not remain accessible to the end user after installation 
    and internal wiring.  

2. Do not allow pieces of metal, wire clippings, or fine metallic 
    fillings from installation to enter the product or else it may 
    lead to a safety hazard that may in turn endanger life or 
    cause electrical shock to the operator.      

3. Circuit  breaker or mains switch must be installed between 
    power source and supply terminal to facilitate power ‘ON’ 
    or ‘OFF’ function. However this mains switch or circuit 
    breaker must be installed at convenient place normally 
    accessible to the operator.     

4. Use and store the instrument within the specified ambient 
    temperature and humidity ranges as mentioned in this 
    manual.     

MECHANICAL INSTALLATION GUIDELINES

1. Prepare the panel cutout with proper dimensions as shown 
    above.

   

2. Fit the unit into the panel with the help of clamp given.

   

3. The equipment in its installed state must not come in close 
    proximity to any heating source, caustic vapors, oil steam, 
    or other unwanted process byproducts.
   

4. Use the specified size of crimp terminal (M3.5 screws) to 
    wire the terminal block. Tightening the screws on the 
    terminal block using the tightening torque of the range of 
    1.2 N.m.

   

5. Do not connect anything to unused terminals. 
   

MAINTENANCE

1. The equipment should be cleaned regularly to avoid blockage 
    of ventilating parts.         

2. Clean the equipment with a clean soft cloth. Do not use 
    isopropyl alcohol or any other cleaning agent.

3. Fusible resistor must not be replaced by operator. 

Page 1

SET

  ENT

UTC 221P

R

PV

SV

ºC

TUNE

3

2 4

235

8

8

8

10

10

9

9

9

3-Wire RTD

2-Wire RTD

Thermocouple

Install jumper 
when using 
2 Wire RTD

+

Sensor Input

(FSD:- Full Scale Deflection)

CONTROL METHOD:

OUTPUT SPECIFICATION:

INPUT SPECIFICATION:

DISPLAY AND KEYS:

CONTROL METHOD:

1

2

3

1 - Control output indication 

2 - Auto tuning “ON” indication

3 - Blinking DP Will Indicate Delay time Count

STATUS LED DESCRIPTION

2345

2500

Made in India

Sensor in

put

TC

+

RTD

-

!

L

N

1

2

3

4

5

6

7

-

+

O/P

S.S.R

 RELAY1

100  
270V AC
    

~

 

50/60 Hz
4VA

NC

NO

C

8

9

10

11

12

13

14

www.multispanindia.com

DIMENSION: