background image

Page - 3

www.multispanindia.com





*  When set Count reaches at set value ,Relay and Buzzer will be ON.
*  Relay will stay on up to the set Time.
*  After completion of the set Time - both ,Relay and Buzzer will be OFF.
*  If the set time is 



.



 then Instrument will work in manual mode and 

    user need to press Reset key to turn OFF Relay & Buzzer.

Set Count - 1:  Advance setting for batch Count.
Set Count - 2:  Batch setting.

Always set the value of set 1 less then set 2.

When it reaches to set count 1, Relay & Buzzer will be ON, & when it reaches
to set count 2, Relay Buzzer will be OFF & Batch Count will be zero.
  

Note:

Press      key and power on the instrument Display will show parameters
‘SLOW’.”MEDIUM” & “FAST”

Set Speed Selection by Pressing      key

SLOW : MAX RPM 500
MEDIUM : MAX RPM 5000
FAST: MAX RPM 15000 

Press        key to save the parameters





Press     Key 
 for 15 sec.

Press     Key To save & exit 
 













   Change 
   Channel
by Pressing
          Key

Working

Procedure to set channel of program 

BC-1046D,2046,445

Содержание BC-1046D

Страница 1: ...ED Display LOWER 4 Digit 7 seg 0 4 green LED Display LOWER 4 Digit 7 seg 0 3 green LED Display BC 2046 BC 445 1 Relay 1C O 230V AC 5A Buzzer 1 Relay 2C O 230V AC 5A Buzzer Technical Specification Connection Diagram OPERATING MANUAL PID TEMPERATURE CONTROLLER UTC 121P 221P 421P Technical Specification Connection Diagram OPERATING MANUAL BATCH COUNTER BC 1046D 2046 445 7 8 9 10 5 6 L N 1 2 3 4 230V ...

Страница 2: ...ress Key Press Key For Program Press Key Press Key Total Batch Count Batch Count BC 1046D 2046 445 Key Operation 1 Press Key to go next parameter 2 Release the Key to save the set point 3 Press Key for manual reset of total count Press Key To save exit Press Key To save exit ...

Страница 3: ...t Set Count 2 Batch setting Always set the value of set 1 less then set 2 When it reaches to set count 1 Relay Buzzer will be ON when it reaches to set count 2 Relay Buzzer will be OFF Batch Count will be zero Note Press key and power on the instrument Display will show parameters SLOW MEDIUM FAST Set Speed Selection by Pressing key SLOW MAX RPM 500 MEDIUM MAX RPM 5000 FAST MAX RPM 15000 Press key...

Страница 4: ...nter the product or else it may lead to a safety hazard that may in turn endanger life or cause electrical shock to the operator 3 Circuit breaker or mains switch must be installed between power source and supply terminal to facilitate power ON or OFF function However this mains switch or circuit breaker must be installed at convenient place normally accessible to the operator 4 Use and store the ...

Отзывы: