
PAGE 22 — MVH502DSB/DSB2 PLATE COMPACTOR — OPERATION AND PARTS MANUAL — REV. #5 (03/11/11)
Figure 21. Vibrator Oil Maintenance
Vibrator Oil Level Check
1. In every 100 hours of operation, with the machine positioned
horizontally, remove vibrator oil level check plug
(Figure 21) off vibrator (19 mm wrench) and see if oil is up to
filler port. Be sure to clean area around check hole to prevent
dirt and dust from entering.
2. In every 300 hours of operation, replace oil (capacity 1,500
cc). For draining oil through level check hole, have the
machine inclined with a sleeper or the like placed under the
compaction plate on opposite side.
* Use engine oil 10W-30 for this lubrication.
Hydraulic Oil
1. Check hydraulic oil in every 100 hours of operation. With
handle bar positioned vertically (storage position), remove
breather plug (Figure 23) off the top of hydraulic pump and
check for proper oil level.
2. Replace hydraulic oil after first 200 hours and in every 1,000
hours of operation.
Replacing Hydraulic Oil
1. Remove the drain plug (Figure 22) at the bottom of the oil
tank with a 6 mm hex wrench and drain the hydraulic oil.
2. Clean the filter with light oil.
3.
Reinstall the drain plug to the oil tank. Apply seal tape or
Roctite #575 to thread portion.
4. Fill tank with hydraulic oil. (Capacity: About 2,500 cc). Use
Shell Tellus Oil #46
or equivalent.
5. After filling tank, temporarily install cover. Loosen bleeder
plug located at the top of the cylinders on side of vibrator
(Figure 23). Air remaining in the circuit will be forced out of
the bleeder plug.
6. Tighten the breather plug. Check oil level in the tank again.
7. Install the cover of oil tank. Coat packing with liquid packing
such as Threebond #1215. Use loctite #242 for mounting
screw.
Figure 22. Hydraulic Oil Maintenance
Figure 23. Bleeder Plug
MAINTENANCE
Always clean the area around the vibrator oil level check hole
before removing oil check plug. This will prevent dirt and
debris from entering the system.
NOTICE
Make sure hydraulic oil i is at a normal safe operating level.
DO NOT
over fill. Over filling (excessive oil) will cause excess
oil to blow out of breather plug.
CAUTION
Содержание Mikasa MVH502DSB
Страница 27: ...PAGE 28 MVH502DSB DSB2 PLATE COMPACTOR OPERATION AND PARTS MANUAL REV 5 03 11 11 DECAL PLACEMENT...
Страница 29: ...PAGE 30 MVH502DSB DSB2 PLATE COMPACTOR OPERATION AND PARTS MANUAL REV 5 03 11 11 VIBRATING PLATE ASSY...
Страница 31: ...PAGE 32 MVH502DSB DSB2 PLATE COMPACTOR OPERATION AND PARTS MANUAL REV 5 03 11 11 BASE AND ENGINE ASSY...
Страница 33: ...PAGE 34 MVH502DSB DSB2 PLATE COMPACTOR OPERATION AND PARTS MANUAL REV 5 03 11 11 BASE AND ENGINE ASSY...
Страница 35: ...PAGE 36 MVH502DSB DSB2 PLATE COMPACTOR OPERATION AND PARTS MANUAL REV 5 03 11 11 VIBRATOR ASSY...
Страница 37: ...PAGE 38 MVH502DSB DSB2 PLATE COMPACTOR OPERATION AND PARTS MANUAL REV 5 03 11 11 VIBRATOR ASSY...
Страница 39: ...PAGE 40 MVH502DSB DSB2 PLATE COMPACTOR OPERATION AND PARTS MANUAL REV 5 03 11 11 HYDRAULIC SYSTEM ASSY...
Страница 41: ...PAGE 42 MVH502DSB DSB2 PLATE COMPACTOR OPERATION AND PARTS MANUAL REV 5 03 11 11 CONTROL ASSY...
Страница 43: ...PAGE 44 MVH502DSB DSB2 PLATE COMPACTOR OPERATION AND PARTS MANUAL REV 5 03 11 11 CONTROL ASSY...
Страница 45: ...PAGE 46 MVH502DSB DSB2 PLATE COMPACTOR OPERATION AND PARTS MANUAL REV 5 03 11 11 BATTERY ASSY...
Страница 47: ...PAGE 48 MVH502DSB DSB2 PLATE COMPACTOR OPERATION AND PARTS MANUAL REV 5 03 11 11 THROTTLE ASSY...
Страница 89: ...MVH502DSB DSB2 PLATE COMPACTOR OPERATION AND PARTS MANUAL REV 5 03 11 11 PAGE 91 NOTES...