PAGE 80 — MAYCO LS600 PUMP — OPERATION AND PARTS MANUAL — REV. #4 (9/15/11)
Figure 69-A. Slump Test (1/3 Full)
Figure 69-C. Slump Test
(Full-Overflow)
Figure 69-B. Slump Test (2/3 Full)
Figure 69-D. Slump Test
(Removing Excess Concrete)
Figure 69-E. Slump Test
(Cone Invert)
Figure 69-F. Slump Test (Measurement)
1. To obtain a representative sample (concrete), take
several samples at three or more regular intervals
throughout the discharge of the mixer or truck.
DO NOT
take samples at the beginning or end of the discharge.
2. Dampen the inside of the cone and place it on a smooth,
moist, nonabsorbent, level surface large enough to
accommodate both the slumped concrete and the
slump cone. Stand on the “foot pieces” throughout the
test procedure to hold the cone firmly in place.
3. Fill the cone 1/3 full by volume (Figure 68-A) and rod
25 times with a 1/2” dia x 24” lg. bullet-pointed steel rod.
(This is a specific requirement which will produce non-
standard results unless followed exactly.) Distribute
rodding evenly over the entire cross section of the
sample.
APPENDIX —
SLUMP TEST PROCEDURE
BULLET POINTED
STEEL ROD
1/2 DIAMETER
24 INCHES LONG
1/3 FULL
FOOT
PIECE
2/3 FULL
FULL
(OVERFLOW)
4. Fill cone another 1/3 (Figure 68-B) which will make the
cone 2/3 full by volume. Rod this second layer 25 times
with the rod penetrating into, but not through, the first
layer. Distribute rodding evenly over the entire cross
section of the layer.
5. Fill cone to overflowing
(Figure68-C). Rod this layer
25 times with rod penetrating
into but not through, the sec-
ond layer. Distribute rodding
evenly over the entire cross
section of this layer.
7. Lift the cone ver tically
(Figure 68-E) with a slow even
motion.
DO NOT
jar the con-
crete or tilt the cone during
this process. ( Invert the with-
drawn cone, and place it next
to, but not touching the
slumped concrete.
6. Remove the excess concrete
(Figure 68-D) from the top of
the cone, using the tamping
rod as a screed.
8. Lay a straight edge (Figure 68-F) across the top of the
slumped cone. Measure the amount of slump in inches
from the bottom of the straight
edge to the top of the slumped
concrete at a point over the
original center of the base .
The slump operation must be
complete in a maximum
elapsed time of 1-½ minutes.
Discard the concrete.
DO NOT
use it in another tests.
Содержание MAYCO LS600
Страница 3: ...MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 PAGE 3 NOTES...
Страница 11: ...MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 PAGE 11 NOTES...
Страница 81: ...MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 PAGE 81 NOTES...
Страница 88: ...PAGE 88 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP NAMEPLATE AND DECALS...
Страница 90: ...PAGE 90 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP NAMEPLATE AND DECALS...
Страница 92: ...PAGE 92 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP FRAME ASSY...
Страница 94: ...PAGE 94 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP AXLE ASSY RIGHT LEFT...
Страница 96: ...PAGE 96 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP BRAKE LINE ASSY...
Страница 98: ...PAGE 98 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP BRAKE LIGHT ASSY...
Страница 100: ...PAGE 100 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP TRAILER HITCH ASSY...
Страница 102: ...PAGE 102 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP BATTERY ASSY...
Страница 104: ...PAGE 104 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP HOPPER ASSY...
Страница 106: ...PAGE 106 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP HOPPER ATTACHMENT ASSY...
Страница 108: ...PAGE 108 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP HOPPER INTERIOR ASSY...
Страница 110: ...PAGE 110 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP SHUTTLE CYLINDER ASSY...
Страница 112: ...PAGE 112 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP LUBRICATION PISTONS ASSY...
Страница 114: ...PAGE 114 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP LUBRICATION PISTONS ASSY...
Страница 116: ...PAGE 116 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP FUELTANK ASSY...
Страница 118: ...PAGE 118 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP HEAT EXCHANGER ASSY...
Страница 120: ...PAGE 120 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP ACCUMULATOR ASSY...
Страница 122: ...PAGE 122 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP REMIXER CONTROL ASSY...
Страница 126: ...PAGE 126 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP ENGINE COVER ASSY...
Страница 128: ...PAGE 128 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP HYDRAULICTANK ASSY...
Страница 130: ...PAGE 130 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP ENGINE ASSY...
Страница 132: ...PAGE 132 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP ENGINE AIR FILTER ASSY...
Страница 134: ...PAGE 134 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP THROTTLE ASSY...
Страница 136: ...PAGE 136 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP WATER SEPARATOR ASSY...
Страница 138: ...PAGE 138 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP HYD PUMP ASSY...
Страница 142: ...PAGE 142 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 CONTROL BOX ASSY LS600 PUMP CONTROL BOX ASSY...
Страница 148: ...PAGE 148 MAYCO LS600 PUMP OPERATION AND PARTS MANUAL REV 4 9 15 11 LS600 PUMP HYDRAULIC STABILIZER ASSY OPTIONAL...