MAYCO LS300P CONCRETE PUMP • OPERATION MANUAL — REV. #1 (02/20/17) — PAGE 51
Long Term Storage (Pump)
Remove the battery.
Drain the fuel tank completely. Treat with a fuel stabilizer
if necessary.
Clean exterior with a cloth soaked in clean oil.
Store unit covered with plastic sheet in moisture and
dust-free location out of direct sunlight.
Long Term Storage (Trailer)
1. Check brake system for proper fluid level in master
cylinder and bleed all lines.
2. Lubricate all links and pivots to prevent any rusting.
3. Remove wheel and drum assemblies and spray a good
anti-corrosion compound (CRC formula 5-56) under
rubber boot on forward end of brake wheel cylinder.
Avoid spraying drum and brake lining.
4. Grease all bearings and reinstall wheel and drum
assemblies.
5. Make sure breakaway cable is fully released.
6. After extended storage, refer to the Maintenance Steps
listed above to insure that the trailer is ready for towing.
CAUTION
NEVER
store the pump with fuel in the tank for any
extended period of time.
ALWAYS
clean up spilled
fuel immediately.
MAINTENANCE
To order go to Discount-Equipment.com