page 18 — gaC6HZR 60 HZ geNeRaTOR• OpeRaTiON aNd paRTs maNual — Rev. #1 (03/31/10)
11
12
18
17
19
20
13
14
15
16
10
10.
spark plug –
Provides spark to the ignition system.
Set spark plug gap to 0.6 - 0.7 mm (0.028 - 0.031 inch)
Clean spark plug once a week.
11.
muffler/Heat shield –
Used to reduce noise and
emissions.
NeveR
touch this heat shield when the
generator/welder is in use. Always allow time for engine
to cool before servicing.
12.
air Cleaner –
Prevents dirt and other debris from
entering the fuel system. Remove wing-nut on top of air
filter cannister to gain access to filter element.
NeveR
run the engine without an air cleaner.
13.
Fuel Tank Cap –
Remove this cap to add unleaded
gasoline to the fuel tank. Replenish with clean unleaded
gasoline. Make sure cap is tightened securely.
dO
NOT
over fill
14.
Choke lever –
Used for starting the engine. Close
the choke lever when starting a cold engine or in
cold weather conditions. The choke enriches the fuel
mixture. Open the choke lever if starting a warm engine
or in warm weather conditions
15.
Fuel Cock lever –
Turn this lever downward to start
(down)the flow of fuel into the carburetor. Turn upward
to stop (up) the flow of fuel.
16.
engine Oil Filler Cap –
Remove this cap/dipstick
when the adding of engine oil is required. See Table 4
for recommended type engine oil.
17.
engine Oil drain plug –
Remove this drain plug
when draining of the oil from the engine crankcase
is required. Fill with recommeded type oil as listed in
Table 4.
18.
Recoil starter (pull rope) –
Manual-starting method.
Pull the starter grip until resistance is felt, then pull
briskly and smoothly.
19.
Fuel gauge –
This gauge is located on top of the fuel
tank. Read this gauge to determine when fuel is low.
20.
Fuel Tank –
Fuel tank capacity is 5 gallons (19 liters)
NOTICE
This
HONda
engine is equipped with a low oil
shutdown capability. A built in sensor will automatically
turn off the engine should the oil level fall below a safe
operating condition. Make sure the generators is placed
on level ground. Placing the generators on level ground
will ensure that the low oil sensor will function properly.
COMpOnents (generatOr)
Figure 4. Generator Components (continued)
Содержание GAC-6HZR
Страница 9: ...GAC6HZR 60 hz GENERATOR operation and parts manual rev 1 03 31 10 page 9 NOTES...
Страница 13: ...GAC6HZR 60 hz GENERATOR operation and parts manual rev 1 03 31 10 page 13 note...
Страница 31: ...GAC6HZR 60 hz GENERATOR operation and parts manual rev 1 03 31 10 page 31 notes...
Страница 36: ...page 36 GAC6HZR 60 hz gENERATOR operation and parts manual rev 1 03 31 10 GAC6HZR GENERATOR ASSY...
Страница 38: ...page 38 GAC6HZR 60 hz gENERATOR operation and parts manual rev 1 03 31 10 GAC6HZR CONTROL BOX ASSY...
Страница 40: ...page 40 GAC6HZR 60 hz gENERATOR operation and parts manual rev 1 03 31 10 GAC6HZR MUFFLER ASSY...
Страница 42: ...page 42 GAC6HZR 60 hz gENERATOR operation and parts manual rev 1 03 31 10 GAC6HZR PIPE FRAME ASSY...
Страница 44: ...page 44 GAC6HZR 60 hz gENERATOR operation and parts manual rev 1 03 31 10 HONDA GX340K1 U1EDN2 AIR CLEANER ASSY...
Страница 62: ...page 62 GAC6HZR 60 hz gENERATOR operation and parts manual rev 1 03 31 10 HONDA GX340K1 U1EDN2 ENGINE FAN ASSY...
Страница 78: ...page 78 GAC6HZR 60 hz gENERATOR operation and parts manual rev 1 03 31 10 HONDA GX340K1 U1EDN2 ENGINE TOOL KIT...
Страница 81: ...GAC6HZR 60 hz GENERATOR operation and parts manual rev 1 03 31 10 page 81 notes...