
ga2.5HR
60 hz gENERATOR • OpERATiON ANd pARTs mANuAl — REv. #0 (12/15/14) — pAgE 19
COMPONENTS GENERATOR
1
2 3
4
5
8
AC CIRCUIT
BREAKER
OFF
22A
GA-2.5HR
120
V
120
AC VOLTMETER
QUARTZ
20A
120V
20A
GFCI PROTECTED
6
7
10
11
12
9
Figure 4. Generator Components
1.
hour meter –
Indicates the number hours the generator
has been in use.
2.
120v Output Receptacle –
NEMA L5-20R twist-lock
receptacle will provide 120V, 20 amps, 60 Hz.
3.
gFCi duplex Receptacles –
NEMA 5-20R, GFCI
receptacle will provide 120V@ 20 amps.
4.
AC-voltmeter –
This voltmeter indicates (with a
mark) the rated 60 Hz (single-phase) output voltage.
In addition the voltmeter can also be used as a
diagnostic tool. If the voltmeter indicator (needle) is
below the rated voltage, engine problems may exist
(low/high RPM's). To prevent damage to the generator
or power tools, turn the generator
OFF
and consult your
authorized Multiquip service dealer.
5.
main Breaker –
This single-pole, 20 amp circuit
breaker protects the generator from short circuiting or
overloading. When starting the generator always have
the circuit breaker placed in the "
OFF
" position.
6.
Engine Oil Filler Cap –
Remove this cap/dipstick
when the adding of engine oil is required. See Table 5
for recommended type engine oil.
7.
ON/OFF switch –
Place engine ON/OFF switch in
the "
ON
" position for normal operation. To turn off the
generator place the switch in the "
OFF
" position
8.
Charcoal Canister –
A container filled with activated
charcoal that traps gasoline vapors emitted by the
fuel
system.
9.
generator housing –
Contains the rotor, rectifier
field coil assembly, armature, bearings and other
components that make up generator assembly.
10.
ground –
This ground connection point should be
connect to a good earth ground (ground rod).
11.
Fuel gauge –
This gauge is located on top of the fuel
tank. Read this gauge to determine when fuel is low.
12.
Fuel Tank Cap –
Remove this cap to add unleaded
gasoline to the fuel tank. Replenish with clean unleaded
gasoline. Make sure cap is tightened securely.
dO
NOT
over fill. Fuel tank capacity is 3.2 gallons (12 liters).
NOTICE
When using a combination of receptacles, total load
should not exceed the rated capacity of the generator.
Содержание ga2.5Hr
Страница 15: ...GA2 5HR 60 hz GENERATOR operation and parts manual rev 0 12 15 14 page 15 note...
Страница 29: ...GA2 5HR 60 hz GENERATOR operation and parts manual rev 0 12 15 14 page 29 generator wiring diagram...
Страница 33: ...GA2 5HR 60 hz GENERATOR operation and parts manual rev 0 12 15 14 page 33 notes...
Страница 38: ...page 38 GA2 5HR 60 hz gENERATOR operation and parts manual rev 0 12 15 14 GA2 5HR GENERATOR ASSY...
Страница 40: ...page 40 GA2 5HR 60 hz gENERATOR operation and parts manual rev 0 12 15 14 GA2 5HR CONTROL BOX ASSY...
Страница 42: ...page 42 GA2 5HR 60 hz gENERATOR operation and parts manual rev 0 12 15 14 GA2 5Hr PIPE FRAME ASSY...
Страница 58: ...page 58 GA2 5HR 60 hz gENERATOR operation and parts manual rev 0 12 15 14 honda gx160rt2eman engine piston ASSY...
Страница 75: ...GA2 5HR 60 hz GENERATOR operation and parts manual rev 0 12 15 14 page 75 notes...