DA7000SSA2/SSA2GH GENERATOR• OPERATION AND PARTS MANUAL — REV. #0 (03/26/15) — PAGE 19
17.
Fuel Drain Plug
— Remove this plug to drain fuel
from the fuel tank.
18.
Frame Ground Lug
— Connect a ground strap
between this lug and a ground rod. Make sure that the
ground rod is inserted deep into the ground to provide
a good earth ground. Consult with local Electrical and
Safety Codes for proper connection based on condition
of use.
19.
120/240V Output Receptacle
— CS6369 twist-lock
receptacle provides 240 V, 60 Hz output at 25 amps,
or 120V, 60 Hz at 50 amps (X2), depending on the
position of the full power switch.
20.
120/240V Output Receptacle
— NEMA L14-30R
twist-lock receptacle provides 240 V, 60 Hz output at
25 amps, or 120V, 60 Hz at 30 amps (X2), depending
on the position of the full power switch.
21.
120V Output Receptacles
— NEMA 5-20R twist-lock
receptacle provides 120V, 60 Hz output at 30 amps,
depending on the position of the full power switch.
22.
Duplex Receptacle
— NEMA 5-20R receptacle
provides 120V, 60 Hz output at 20 amps.
23.
30 Amp Breaker (for L14-30R)
— Single-pole, 30 Amp
circuit breaker protects the 120V twist-lock receptacle.
When starting the generator, always have this circuit
breaker placed in the "OFF" position.
24.
30 Amp Breaker (for L5-30R)
— Single-pole, 30 Amp
circuit breaker protects the 120V twist-lock receptacle.
When starting the generator, always have this circuit
breaker placed in the "OFF" position.
25.
20 Amp Breaker (for 5-20R)
— Single-pole, 20 Amp
circuit breaker protects the 120V duplex receptacle.
When starting the generator, always have this circuit
breaker placed in the "OFF" position.
26.
GFCI Sensing Module
— Interrupts power, by opening
the main breaker, when a ground fault exists.
27.
Main Breaker
— 2-pole, 25 Amp circuit breaker
protects the generator from short circuiting or
overloading. When starting the generator, always have
this circuit breaker placed in the "OFF" position.
COMPONENTS (GENERATOR)
Figure 4. Generator Components (2 of 3)
18
22
23
24
25
19
27
26
17
21
20
Содержание DA7000SSA2
Страница 64: ...PAGE 64 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 GENERATOR ASSY...
Страница 66: ...PAGE 66 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 CONTROL PANEL ASSY...
Страница 68: ...PAGE 68 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 ELECTRIC PARTS ASSY...
Страница 70: ...PAGE 70 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 ENGINE AND RADIATOR ASSY...
Страница 74: ...PAGE 74 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 BATTERY ASSY...
Страница 76: ...PAGE 76 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 MUFFLER ASSY...
Страница 78: ...PAGE 78 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 FUEL TANK ASSY...
Страница 80: ...PAGE 80 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 ENCLOSURE ASSY...
Страница 82: ...PAGE 82 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 ENCLOSURE ASSY...
Страница 84: ...PAGE 84 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 RUBBER SEALS ASSY...
Страница 106: ...PAGE 106 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 KUBOTA Z482 E4B ENGINE FLYWHEEL ASSY...
Страница 112: ...PAGE 112 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 KUBOTA Z482 E4B ENGINE STOP SOLENOID ASSY...
Страница 132: ...PAGE 132 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 KUBOTA Z482 E4B ENGINE STARTER ASSY...
Страница 140: ...PAGE 140 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 KUBOTA Z482 E4B ENGINE WATER PUMP ASSY...
Страница 142: ...PAGE 142 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 KUBOTA Z482 E4B ENGINE WATER PIPE ASSY...
Страница 144: ...PAGE 144 DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 KUBOTA Z482 E4B ENGINE FAN ASSY...
Страница 159: ...DA7000SSA2 SSA2GH GENERATOR OPERATION AND PARTS MANUAL REV 0 03 26 15 PAGE 159 NOTES...