background image

Recommended Installation Procedure

Doc. No 10-8381

Release 1.0, 1/14/2005

Page 6 of 6

8.0.2

Use caution when removing layers. Splicing

shears or a cable knife may be used to start the
removal by placing a small knick at the point where
the layer joins the grommet.

Figure 11

8.0.3

Pull on the layer at the location of the nick.

Figure 12

8.0.4

Any differential between the OD of the cable

and the adjusted ID of the grommet can be made up
with a layer of sealing tape included in each closure
kit.

8.0.5

Place a layer of silicone grease around the

inside diameter of the grommet where the cable will
seat.

8.0.6

Install the grommets on the cable with the

Square end flush up against the strain relief placed
earlier and face the grommet slit up.

Figure 13

NOTE:

Squeeze the two strain relief clamps tight to

the grommet flange

8.0.7

Apply a thin layer of Silicone Grease to the

gaskets entire surface of the lower and upper end
plates of the closure.

See Figure 14

Figure 14

8.0.8

Apply a liberal layer of Silicone Grease on the

exterior surface of the grommet and lower the
assembly down into the lower end plate of the
closure

. Refer to Figure 15

Figure 15

Содержание Starfighter 4048D

Страница 1: ...or installing mid accessed cables Split end plates are gasketed and secured to one another with three hex head bolts End plates have two feeder or express ports four branch or lateral drop ports a bon...

Страница 2: ...Starfighter Aerial Hangar Kit 10 8007 4048 SSTP Splice Tray 24 Single 48 Mass Fusion 10 8181 4048D CAK Cable Addition Kit Individual Grommets 10 8084 4 p o r t I n s e r t 2 0 t o 2 4 5 m mt o 6 m m...

Страница 3: ...Air Pressurization source 5 0 Cable Preparation The closure is designed for mid accessed and full cut cable entries The following information serves as a guideline for sheath opening lengths 5 1 Mid A...

Страница 4: ...of cable sheath and bundling designs Note that the CSM clamp provides both cable strain relief and CSM termination If Core Tube cabling is being installed the CSM extension of the combination clamp wi...

Страница 5: ...ne of the supplied Hose Clamps Tighten the clamp but do not overtighten 7 1 3 Using a standard pair of pliers crimp the CSM clamp end to secure it to the CSM 7 1 4 For Central core cables break off th...

Страница 6: ...each closure kit 8 0 5 Place a layer of silicone grease around the inside diameter of the grommet where the cable will seat 8 0 6 Install the grommets on the cable with the Square end flush up agains...

Страница 7: ...nut All ports are equipped with the cable port feed through and blank port plug at the factory The feed through has a insert that accommodates cables with an OD of 3 5 t o 6 5 w h i c h w i l l b e r...

Страница 8: ...en up the hinge tray storage plate and route all fiber bundles in a counter clockwise direction securing the bundles as you go using the twist loks supplied Refer to Figure 22 Figure 22 9 1 3 Secure a...

Страница 9: ...s e m b l e t h e V b a n d o v e r t h e D o m e a n d E n d P l a t e s H a n d s t a r t o n e b o l t o f t h e V band first and then start the other 10 0 7 I n s p e c t t h e V b a n d f o r p r...

Отзывы: