Multiform MULTISPOT G-II-HS5034 Скачать руководство пользователя страница 4

User Manual: Multispot GII-HS5034

    

                                       

 

 

 

V2.00 (08-2013)                                                                                                                                                

4

 

 

 

Protection from electric shock: 

1.  Only connect this unit to a mains socket outlet with protective earth 

connection, ground-fault (earth-fault) and overload protection.  

2.  Where the mains plug or an appliance coupler is used as a dis-

connect device, such device shall remain readily operable.  

3.  To pull the AC Cord out of the wall outlet or the unit’s AC socket, 

never pull the cable itself, but only the AC plug.  

4.  Disconnect the unit from AC supply before any kind of cleaning on 

the product. Use smooth and dry cloth only for cleaning.  

5.  Do not expose this unit to any dripping or splashing liquids, and do 

not place objects filled with liquids, such as vases, on the unit.  

6.  Do not operate this unit near to open water or in high humidity.  
7.  Choose the position of the AC cord according to the lowest risk of 

damage by foot steps or by squeezing it.  

8.  Do not open the unit for service, there are no user-serviceable 

parts inside. Warranty will be void in any case of unauthorized 
service by the user or other not authorized persons.  
 

 

 

Protection from fire:

1.  Take care of not placing the unit near sources of heat (e.g. 

powerful amplifiers, fog machines). 

2.  Allow at least about 0.15m (6 ins.) between this unit and other 

devices or a wall to allow for proper cooling. 

3.  Take always care of sufficient air convection in the unit’s 

environment to avoid overheating. Make sure air convection slots 
are not blocked. Do not operate this unit in environmental 
temperatures exceeding 40 degrees Celsius.  

4.  Be sure this fixture is kept at least 0.75m (30ins.) away from any 

flammable materials (decoration etc.).  

5. 

Do not stick filters, masks or other materials directly on the LEDs or 
the LED cover screen. 

 

6.  Check the total maximum power of your AC wall outlet if you 

connect several units to one wall outlet and avoid any overloading.

7.  If the device itself has an AC outlet for providing power to other 

units, make sure to not exceed the specified maximum load. 
 

 

 

Protection from injury and damage: 

1.  Never use any accessories or modifications not authorized by the 

manufacturer of this unit. 

2.  Choose a location for operation where the unit is protected from 

vibration and where a fixed mounting position is provided. In case 
of overhead-mounting, follow applicable rigging requirements.  

3.  Before plugging the AC cord in the wall outlet, check whether the 

AC plug, the mains voltage and frequency are the same as this 
product is specified for. If not, contact you dealer immediately. 

User Manual: Multispot GII-HS5034

    

                                       

 

 

 

V2.00 (08-2013)                                                                                                                                                

21

 

used together to do not exhibit different color behaviour, please make sure that all 
fixtures used together are calibrated to the same color behaviour.  

 

 EDIT 

 

 

Automatic DMX addressing.

 This allows to use the first device in a row of units 

connected via DMX to be used as a master unit and set all subsequent units’ DMX 
address automatically. On the first (master) unit, in EDIT menu, use the left/right arrows 
until the display shows 

“ADMX”

. You can now decide to either address all subsequent 

units in GDMX mode with the same channel scheme as on the master unit, but 
consecutive DMX addresses for individual control; or to set all subsequent units to 
SLAVE mode for mutual control. To enable GDMX auto addressing, press the + button 
to start the auto addressing process and keep it pressed; the display will show “GDMX” 
when done.  To enable SLAVE auto addressing, press the - button to start the auto 
addressing process and keep it pressed; the display will show “SLAVE” when done.  
 

Auto Lock

. Use the left/right arrows until the display shows ALOK. Press any of the +/- 

button to alternate between “on” or “off”. When on, the unit will lock itself after more 
than 1 minute of no use of the UI. When off, the UI will remain unlocked. To unlock a 
locked unit, press the left and the right arrow buttons simultaneously.  
 

Auto Display off

. Use the left/right arrows until the display shows ADIS. Press any of 

the +/- button to alternate between “on” or “off”. When on, the unit will disable the LCD 
backlight after more than 1 minute of no use of the UI. When off, the display backlight 
will remain enabled. Note: The display elements themselves remain active.   
 

Temperature Display.

 Use the left/right arrows until the display shows “TEMP”. Press 

any of the +/- button to alternate between “on” or “off”. When on, the unit will display the 
temperature in °C after more than 1 minute of no use of the UI. 
 

Reset.

 Use the left/right arrows until the display shows “RSET”. Press the + or the - 

button to enter the RESET MODE and the display will show ‘YES+’ Press the + button 
to activate a reset to the factory default settings and calibration (the – button is disabled 
in this menu). For confirmation, the LED panel flashes once. The reset excludes the 
operation hours.   
 

Operation Hours.

 Use the left/right arrows until the display shows HOUR. Press the – 

button and the display will show the operating hours up to 9999 hours. Operating hours 
exceeding the first 9999 hours can be extracted from the unit via RDM by a qualified 
service technician.  
 

FW Version.

 Use the left/right arrows until the display shows VERS. Press either of the 

–/+ buttons to have the display showing the firmware version.  
 
 
 

Содержание MULTISPOT G-II-HS5034

Страница 1: ...034 High Power DMX Controlled LED light source For firmware 50 010 0088 00113 1 03 MS GII HS5034 RevN Updated versions of this document may be available at WWW MULTIFORM LIGHTING COM RevB 08 2013 Orde...

Страница 2: ...The Multispot GII is a high power DMX controlled LED light source for both indoor and outdoor applications which range from architectural illumination to stage lighting Available in various LED config...

Страница 3: ...ltispot GII HS5034 V2 00 08 2013 3 WARNING Shock hazard Equipment must be properly grounded WARNING Hot surface Risk of skin burn or skin irritation WARNING Fire hazard WARNING Laser radiation Risk of...

Страница 4: ...you dealer immediately User Manual Multispot GII HS5034 V2 00 08 2013 21 used together to do not exhibit different color behaviour please make sure that all fixtures used together are calibrated to t...

Страница 5: ...fixture in all available operation modes also DMX To make sure that several fixtures User Manual Multispot GII HS5034 V2 00 08 2013 5 4 The surface of the device may get hot during operation and heat...

Страница 6: ...Manual Multispot GII HS5034 V2 00 08 2013 19 SL11 1 loop per 6 seconds SL24 2 8 loops per second SL12 1 loop per 4 seconds SL25 3 2 loops per second Once the speed level is set and no changes done the...

Страница 7: ...e the connectors please make sure that yourself or the person in charge has the relevant experience in safe work methods for electrical equipment service and maintenance the unit is disconnected from...

Страница 8: ...unplugged in step 3 18 Place the rear cover with the attached electronics assembly on the back side of the power supply compartment NOTE It is extremely important that the rubber seal which is inserte...

Страница 9: ...n as last set The same happens if the color preset is changed by the left right arrows in this case the dimming level mode is left immediately and the dimming level will remain as last set Color setti...

Страница 10: ...on 3 RIGHT ARROW Button 4 Button 5 Button 6 DISPLAY Sound to Light Indicator 7 DISPLAY 4 Digit Message Display Area 8 DISPLAY Indicator 9 DISPLAY Indicator 10 DISPLAY ARROW Indicators 11 DISPLAY DMX S...

Страница 11: ...the lens panel in an inappropriate manner may defeat the waterproof capabilities of the fixture and may void any warranty of the manufacturer if water intrudes into the unit It is essential to follow...

Страница 12: ...nmental temperatures of up to 40 degrees Celsius For proper operation the unit must be operated with unobstructed air convection to its outside metal case Do not Operate the MULTISPOT GII HS5034 LED i...

Отзывы: