Multiform MULTISPOT G-II-HS5034 Скачать руководство пользователя страница 11

User Manual: Multispot GII-HS5034

    

                                       

 

 

 

V2.00 (08-2013)                                                                                                                                                

14

 

weight of the device when installing the unit. This secondary safety attachment 
should be installed in a way that no part of the installation can drop more than 
20cm if the main attachment fails. 

 

Never stand directly below the device when mounting, removing, or servicing the 
fixture. Make sure the area below the installation place is free from unwanted 
persons during rigging, de-rigging and servicing. 

  The operator has to make sure that the safety-relating and machine-technical 

installations are approved by an expert before using them for the first time. The 
installations should be re-inspected every year. 

 

Make sure to comply with applicable cooling requirements if any.  

 

 

Getting started: making AC supply connections

 

 

 

 

 

 
 

Risk of fire / Safety risk 

• The MULTISPOT-GII-HS5034 LED requires an AC power source with 
sufficient power carriage and correct grounding to ensure safe 
operation. The AC power source must be equipped with a circuit 
breaker and earth leakage detector. Make sure to only use compliant 
AC supply lines.  
• The MULTISPOT-GII-HS5034 LED has an AC outlet that is designed 
to carry loads of no more than 10A. Make sure that all connected 
devices in a chain fed by the first device do not exceed a maximum of 
10A current consumption.  

 

Getting started: making DMX control connections

 

 
Connect the MULTISPOT-GII-HS5034 to a suitable DMX controller where needed, and 
interconnect several units by means of their DMX In/Outputs as required. The last unit 
shall be fitted with a proper 120 Ohm termination resistor-equipped DMX-plug as 
shown in below drawing. Please make sure that all used DMX cables comply to below 
standard: 
 

 

User Manual: Multispot GII-HS5034

    

                                       

 

 

 

V2.00 (08-2013)                                                                                                                                                

11

 

 

Getting started: changing the lens panel (only if required)

 

 
Your MULTISPOT-GII-HS5034 has been factory-fitted with the default lens panel. If you 
need to exchange the lens panel to achieve specific dispersion angles, please contact 
your distributor for availability information of other lens panels and follow the below 
procedure to exchange the lens panel if required.   

 

Reliability risk:

 Exchanging the lens panel in an inappropriate manner 

may defeat the waterproof capabilities of the fixture and may void any 
warranty of the manufacturer if water intrudes into the unit. It is 
essential to follow the below instructions to maintain the waterproof 
capabilities of the fixture and its product warranty subsequently.  

 

Before you start to exchange the lens panel, please make sure that: 

 

the unit is completely dry, and at room temperature.  

  the location chosen to exchange the lens panel does not have more than 40% 

relative humidity and the temperature during the exchange does not exceed 40 
degrees Celsius. These parameters are important to avoid later condensation of 
the water contained in the environmental air when the unit works at lower outside 
temperatures. 

 

The screw driver used to dismantle and re-assemble the unit is properly matching 
the screws to avoid any damage to the screws. This will require a 4mm HexInsert 
screw driver.  

  The screw driver has an in-built torque measurement or you have other torque-

measurement devices on hand to make sure that screws are fastened with the 
right torque during re—assembly.   

 
To exchange the lens panel, follow the below procedure: 
 

1)  Make sure the unit is switched off and cooled down for at least 30 minutes 

after last operation. Detach all cables.  

2)  Lay the unit face-down on a stable but soft surface (like a table covered with a 

towel), and remove the 8 screws which connect the main fixture body with the 
front frame (Illustration step A).  

3)  Turn the unit around and lift off the front frame, while you hold down the front 

glass. Holding down the front glass is a safety precaution, since due to the 
adhesion of the soft rubber of the front glass seal, it could potentially happen 
that the front glass including its rubber seal “stick” to the front frame and fall 
out during the removal procedure, potentially damaging the front glass. 

4)  Carefully lift off the front glass including the glass seal (Illustration step B).   
5)  Unscrew and remove the 5 lens panel screws holding the lens panel.  
6)  Remove the lens panel by vertical lifting it off. It is important to expedite this 

process absolutely perpendicular to the LED panel, as excessive tilting of the 
lens panel versus the LED panel can damage the LEDs. Use both hands and 
the provided finger grip points and lift off the lens panel.  

Содержание MULTISPOT G-II-HS5034

Страница 1: ...034 High Power DMX Controlled LED light source For firmware 50 010 0088 00113 1 03 MS GII HS5034 RevN Updated versions of this document may be available at WWW MULTIFORM LIGHTING COM RevB 08 2013 Orde...

Страница 2: ...The Multispot GII is a high power DMX controlled LED light source for both indoor and outdoor applications which range from architectural illumination to stage lighting Available in various LED config...

Страница 3: ...ltispot GII HS5034 V2 00 08 2013 3 WARNING Shock hazard Equipment must be properly grounded WARNING Hot surface Risk of skin burn or skin irritation WARNING Fire hazard WARNING Laser radiation Risk of...

Страница 4: ...you dealer immediately User Manual Multispot GII HS5034 V2 00 08 2013 21 used together to do not exhibit different color behaviour please make sure that all fixtures used together are calibrated to t...

Страница 5: ...fixture in all available operation modes also DMX To make sure that several fixtures User Manual Multispot GII HS5034 V2 00 08 2013 5 4 The surface of the device may get hot during operation and heat...

Страница 6: ...Manual Multispot GII HS5034 V2 00 08 2013 19 SL11 1 loop per 6 seconds SL24 2 8 loops per second SL12 1 loop per 4 seconds SL25 3 2 loops per second Once the speed level is set and no changes done the...

Страница 7: ...e the connectors please make sure that yourself or the person in charge has the relevant experience in safe work methods for electrical equipment service and maintenance the unit is disconnected from...

Страница 8: ...unplugged in step 3 18 Place the rear cover with the attached electronics assembly on the back side of the power supply compartment NOTE It is extremely important that the rubber seal which is inserte...

Страница 9: ...n as last set The same happens if the color preset is changed by the left right arrows in this case the dimming level mode is left immediately and the dimming level will remain as last set Color setti...

Страница 10: ...on 3 RIGHT ARROW Button 4 Button 5 Button 6 DISPLAY Sound to Light Indicator 7 DISPLAY 4 Digit Message Display Area 8 DISPLAY Indicator 9 DISPLAY Indicator 10 DISPLAY ARROW Indicators 11 DISPLAY DMX S...

Страница 11: ...the lens panel in an inappropriate manner may defeat the waterproof capabilities of the fixture and may void any warranty of the manufacturer if water intrudes into the unit It is essential to follow...

Страница 12: ...nmental temperatures of up to 40 degrees Celsius For proper operation the unit must be operated with unobstructed air convection to its outside metal case Do not Operate the MULTISPOT GII HS5034 LED i...