4
TROUBLESHOOTING
•
If
S-E
displays on the LCD the heating sensor has gone open circuit.
•
If
H-E
displays on the LCD the heating core has gone open circuit.
•
To replace the heater assembly allow the tool to fully cool to room temperature.
•
Disconnect the station from the mains supply.
•
Remove the two screws in the handle and unscrew the heat shroud and slide it off
the heater tube so the handle can be split open.
•
Carefully lift out the fan and remove the screws holding the connector PCB to the
handle and turn it over.
•
Note the location and wiring colours for the heating element and unsolder them
from the PCB.
Do not
disturb the black ground wire from the heater tube.
•
Slide the heating element out of the heater tube complete with the mica paper
wrapping.
•
Apply the mica wrap to the new element and slide it into position inside the tube.
•
Resolder the wires to the PCB as before.
•
Reposition the PCB into the handle half and replace the screws.
•
Place the fan into position and replace the upper handle half.
•
Replace and tighten the two screws and refit the heater shroud.
•
Reconnect the mains supply and test and if required
re-calibrate the tool.
SPECIFICATIONS
Input Voltage
220-240V~50Hz
Power
700W Max
Display
Red LCD Digital
Temperature Range
100
o
C - 500
o
C
Accuracy
±35
o
C
Stability
±5
o
C
Air Volume
0-120 litres/min
Air Supply
Turbofan
INFORMATION ON WASTE DISPOSAL FOR CONSUMERS OF
ELECTRICAL & ELECTRONIC EQUIPMENT.
When this product has reached the end of its life it must be treated as Waste Electrical &
Electronics Equipment (WEEE). Any WEEE marked products must not be mixed with general
household waste, but kept separate for the treatment, recovery and recycling of the materials
used. Contact your local authority for details of recycling schemes in your area.
Made in China. LS12 2QQ
Man Rev 1.1
Heater Tube
Mica Wrap Heater Element
Heat Shroud
PCB
Air Duct
Fan
Screws
Содержание MP740111