background image

5

Temperature Mode

• 

To switch between Celsius or Fahrenheit display, press and hold the LOCK/VACUUM 

button when powering on the station.

• 

The mode is displayed on the RH side of the LCD.

• 

The previously used setting is retained on subsequent use. 

Hot Air Tool Adjustment (Channel 3 only)

• 

Long press to turn on channel 3.

• 

Press button 3 to activate and make adjustments to the temperature or air flow rate.

• 

Press button 1 to select temperature adjustment mode then use the UP or DOWN buttons 

to adjust the required temperature.

• 

Press button 2 to select the fan mode then use the UP or DOWN buttons to adjust the 

required air flow rate. 

• 

To lock the channel so settings cannot be changed press and hold the LOCK/VACUUM 

button until the padlock display changes mode. 

Key Beep Function

• 

To switch the key sound feature on or off press and hold the UP and DOWN buttons while 

powering on the station.

• 

The speaker symbol displays on the RH side of the LCD when the feature is active.

• 

The previously used setting is retained on subsequent use. 

Desoldering Gun Maintenance

• 

If the desoldering gun requires maintenance the symbol 

 displays. The waste 

collector needs emptying.

Removing solder waste:

The collector tube must be emptied of solder waste as required or the efficiency of 

operation will be impaired. 

 

• 

Switch off the mains power and allow the desoldering gun to cool fully. 

 

 

 

 

 

 

• 

Press the latch down on the rear of 

the gun and slide the rear cover clear 

from the collection tube. 

 

 

Содержание MP740029

Страница 1: ...1 4 in 1 Rework Soldering Station Model MP740029...

Страница 2: ...arts before the soldering tip has cooled down completely Do not use the product near flammable items Turn the power off when this product is not in use The soldering iron must be placed on its stand w...

Страница 3: ...e Error Indicator Power Display Bar Indicator Mode Indicator Tool Indicator Air Volume Display Air Output indicator Power Switch Channel 1 Indicator Channel 1 Indicator Channel 3 Indicator Channel 1 L...

Страница 4: ...isplayed and the channel cannot be activated Channel 3 is used for the hot air gun tool only and has additional displays to indicate when the air fan is on and the airflow rate Temperature Adjustment...

Страница 5: ...lock the channel so settings cannot be changed press and hold the LOCK VACUUM button until the padlock display changes mode Key Beep Function To switch the key sound feature on or off press and hold...

Страница 6: ...ith a temperature measurement meter set up appropriately Press and hold the LOCK VACUUM button and Button 1 for 3 seconds to enter calibration mode With a temperature set e g 350o C measure the actual...

Страница 7: ...mperature Range 150 500o C 150 500o C 300 500o C 150 500o C Temp Stability 5o C 2o C 2o C 2o C Air Flow 5 23 litres min Heater Core Integrated Element Temperature Sensor Thermocouple Sleep Mode Switch...

Страница 8: ...y and recycling of the materials used Contact your local authority for details of recycling schemes in your area Made in China LS12 2QQ Man Rev 1 1 Mains Power 230V 50Hz Power 900W Max Sleep Mode Temp...

Отзывы: