multicomp pro MP730835 Скачать руководство пользователя страница 2

Page <2>

V1.0

24/08/21

Newark.com/multicomp-pro
Farnell.com/multicomp-pro
Element14.com/multicomp-pro

1. Overview

MP730835 is a smart digital multimeter, it can automatically identify the function and range to improve the operation  

efficiency. EBTN screen enables user to get a clear reading even working in dark environments. This product conforms to CE 

safety standard, which ensures users’ safety when operating in CAT Ill 600V environment. Its unique appearance and 

 

compact design makes it a great tool for home and DIY applications.

2. Features

1)  Automatically detect power level at start up, green light means normal while red light and buzzer beep means power level 

is low.

2) Automatically identify input signals (resistance, DC/AC voltage and current).
3) On any function mode, connect the probe to the ‘mNsocket to switch to current measurement.
4)  NCV senses electric field strength and display results via LED, green light means weak electric field, red light means 

strong electric field.

5) On LIVE mode, distinguish between neutral and live wire via light colour and buzzer.
6) Maximum voltage is 600V, with over voltage/current alarms.
7) Large capacitance measurement (4mF).
8) EBTN display

Please carefully read “Safety Instructions” and “Attention” sections In this manual.

3. Accessories

Open the box and check whether the meter and the following items are missing or damaged:

1) User manual--------1 piece

2) Probes--------1 pair

4. Safety instructions

Please pay attention to “Attention” notices below. Warning means it may pose hazard to users, and may damage the meter 

or device. This multimeter meet with EN61010-2-030/61010-2-033, EN61326-1 safety standard of electromagnetic radiation 

protection, and meet with safety standard of double insulation, over-voltage CAT Ill 600V, pollution level 2. If user do not 

 

operate according to the instructions,the protection provided by the meter may be impaired.
1)  Before use,please check the meter and probe to make sure there is no any damage or abnormity. If the meter or probe is 

significantly damaged, or if you think the meter cannot function properly, please do not use the meter.

2) Do not use the meter if the rear housing or battery housing is not covered up, otherwise it might pose a shock hazard.
3)  When using the meter, your fingers must be placed behind the finger guard ring of the probe, do not touch exposed wire, 

connectors,terminals, circuit.

4) When measuring, never change the range setting to avoid damage to the meter!
5)  Do not apply voltage over 600V between any meter terminal and earth ground to prevent electric shock and damage to the 

meter.

6) Be cautious when the measured voltage is higher than 60V (DC) or 30Vrms (AC).
7)  Only measure the voltage/current that are within the specified limit. Disconnect with all power source and fully discharge 

the capacitor power before measuring resistor, diode or circuit, otherwise the measurement accuracy might be affected.

8)  When the “ “symbol appears on the LCD, please replace the batteries in time to ensure the measurement accuracy. Take 

out the batteries if the meter is not in use for a long time.

9) Do not change the internal circuit of the meter to avoid damage to the meter and user!
10)  Do not use or store the meter in high temperature, high humidity, flammable, explosive environment or In strong electro

-

magnetic field.

11) Clean the meter casing with a damp cloth and mild detergent. Do not use abrasives or solvents.

Содержание MP730835

Страница 1: ...Page 1 V1 0 24 08 21 Newark com multicomp pro Farnell com multicomp pro Element14 com multicomp pro Smart Digital Multimeter User Manual Part Number MP730835 ...

Страница 2: ...61010 2 033 EN61326 1 safety standard of electromagnetic radiation protection and meet with safety standard of double insulation over voltage CAT Ill 600V pollution level 2 If user do not operate according to the instructions the protection provided by the meter may be impaired 1 Before use please check the meter and probe to make sure there is no any damage or abnormity If the meter or probe is s...

Страница 3: ...ty Overload display OL or OL Drop proof one meter Power supply 2 AAA 1 5V batteries Dimension 130mm 65mm 2Bmm Weight About 137g including batteries Altitude 2000 meters Operating temperature and humidity 0 C to 30 C 80 RH 30 C to 40 C 75 RH 40 C to 50 C 45 RH Storage temperature and humidity 20 C to 60 C SQ RH EMC RF field 1V m Overall accuracy specified accuracy 5 range RF field 1V m No specified...

Страница 4: ... loose Do not input AC DC voltage over 30V for safety 3 Continuity detection 1 Plug the red probe into VΩ socket plug the black probe into COM socket 2 Scan intelligent identification state can be set if users want to switch to manual mode select range scale and connect the probe to the terminals of circuit load in parallel If the resistance is 300 the buzzer beeps continuously which means the cir...

Страница 5: ...el When the measured current is greater than 5A the measurement should be less than 10s the measured interval should be more than 5 minutes 7 NCV Figure 2 Electric field detection When the NCV sensing end gets close to the charged electric field such as the socket or the insulated wire the LCD displays or the buzzer beeps green LED flicker As the electric field strength increases the LCD display m...

Страница 6: ...shing the neutral live wire If there is high voltage current the meter may provide an inaccurate measurement result An accurate measurement result is based on the LCD display and beep frequency 10 Technical Index Accuracy reading digit number periodical calibration is one year Temperature and humidity 23 C 5 C 80RH Temperature coefficient On the condition of 18 C to 28 C environment temperature fl...

Страница 7: ... 999A 0 001A The identified minimum current is about 1mA Accuracy scope 5 to 100 range 5 Continuity test Range Resolution Accuracy Overload protection 400 00 0 10 300 buzzer beeps 50Ω buzzer not beep the open circuit voltage is about 2 0V 600 Vrms 6 Resistance Range Resolution Accuracy Overload protection 400 0Ω 0 1Ω 1 0 2 600Vrms 4 000kΩ 0 001kΩ 0 8 2 40 00kΩ 0 01kΩ 400 0kΩ 0 1kΩ 4 000MΩ 0 001MΩ ...

Страница 8: ...xposed wire 70V AC 50Hz 60Hz 1 If not detected and AC symbol Is displayed 2 If neutral wire is detected keeps unchanged 3 When Live wire of electric supply is detected LIVE and is displayed on LCD the beep frequency and LED flickering frequency will change based on the sensing strength Red light indication LIVE flickers and buzzer beeps 11 Maintenance and repair Figure 4a Attention Please make sur...

Страница 9: ...Information and the suitability of the products for their purpose and not make any assumptions based on information included or omitted Liability for loss or damage resulting from any reliance on the Information or use of it including liability resulting from negligence or where the Group was aware of the possibility of such loss or damage arising is excluded This will not operate to limit or rest...