2

Please read these instructions carefully before use and retain for future reference.

This instrument is designed and manufactured in compliance with: G84793,  

lEC61010-1, CAT III 600V, Pollution Degree 2 and Double Insulation standards.

• 

Check the test leads, probes and case insulation before using. If you find any 

breakage or abnormality, or you consider the device is broken, stop using the 

device immediately.

• 

When using the test probes, keep your fingers behind the finger protection ring.

• 

Do not use the meter with the back cover open.

• 

Select appropriate test range for measurements.

• 

Ensure all inputs are less than the range selected otherwise it may cause electrical 

shock or meter damage.

• 

Do not change the range selector position during voltage or current 

measurements.

• 

Do not apply a voltage over 600V between COM terminal and ground.

• 

Take caution when working voltages are above 60V DC or 30V AC rms.

• 

Do not connect the meter to voltage signals when the range selector is on current, 

resistance, diode or continuity range.

• 

When measuring current, each single measurement should be shorter than 10 

seconds. For current values over 5A, the wait period between each measurement 

must be longer than 15 minutes.

• 

When a measurement has been completed, disconnect the testing probes from 

the circuit under test.

• 

Replace the batteries as soon as the low battery indicator appears on the display.

• 

Remove dead batteries from the meter or if it is not going to be used for a long 

time.

• 

Never mix old and new batteries together, or different types of batteries.

• 

Never dispose of batteries in a fire, or attempt to recharge ordinary batteries.

• 

Before replacing the battery, turn off the meter and disconnect all the test probes.

• 

To prolong battery life turn off the meter after use.

• 

CAT III: Measurement category III is for measurements performed in the building 

installation. Examples are measurements on distribution boards, circuit-breakers, 

and wiring, such as cables, bus-bars, junction boxes, switches and socket-outlets 

in the fixed installation, and equipment for industrial application and some other 

equipment such as stationary motors with permanent connection to the fixed 

installation.

• 

Only use test leads and probes that are in compliance with IEC 61010-031, and 

rated CAT III 600V.

SYMBOL GUIDE

Low battery 

Grounding

Warning

Continuity Buzzer

AC

DC

Fuse

Double insulated

Diode

IMPORTANT SAFETY INFORMATION

Содержание MP730007

Страница 1: ...1 Model MP730007 and MP730008 Digital Multimeter ...

Страница 2: ...0 seconds For current values over 5A the wait period between each measurement must be longer than 15 minutes When a measurement has been completed disconnect the testing probes from the circuit under test Replace the batteries as soon as the low battery indicator appears on the display Remove dead batteries from the meter or if it is not going to be used for a long time Never mix old and new batte...

Страница 3: ...put voltage 600V AC DC the buzzer will continuously beep indicating measure range is at it s limit If the input current 10A AC DC buzzer will continuously beep indicating measure range is at it s limit Disconnect the probes from the circuit under test when changing the range If the Display shows OL it indicates the measured voltage is out of range In this case turn the range selector to a higher r...

Страница 4: ...asurement When there is no input such as in open circuit condition the instrument will display OL When making an in circuit measurement disconnect all power supplies and discharge all the capacitors When measuring low resistance the test leads will produce 0 1Ω 0 2Ω measurement error To obtain accurate measurement short the test leads and use REL function If the resistance when shorted is more tha...

Страница 5: ...nge selector to battery measurement position Insert the red test lead to VΩmA terminal black to COM terminal Connect the red test probes to and black to poles The LCD displays the battery status Notes Do not input over 60V DC or 30V AC Measuring Temperature MP730007 only Switch the range selector to temperature position After OL is displayed insert the K type thermocouple to the device terminals V...

Страница 6: ... 0 2 6 000kΩ 6000Ω 0 1kΩ 1Ω 0 8 2 60 00kΩ 0 01kΩ 0 8 2 600 0kΩ 0 1kΩ 0 8 2 60 00MΩ 0 01MΩ 2 0 5 DIODE TEST Range Resolution Remarks 0 001V MP730007 Open circuit voltage 4V test current about 1 5mA MP730008 Open circuit voltage 2 1V test current about 1mA Silicon PN junction voltage 0 5 0 8V OPERATING PARAMETERS Ambient temperature 23º 5º Relative Humidity 75 DC VOLTAGE Range Resolution Accuracy 60...

Страница 7: ... is only applicable for temperature less than 250ºC 482ºF CAPACITANCE Range Resolution Accuracy 9 999nF 0 001nF REL mode 4 10 99 99nF 0 01nF 4 5 999 9nF 0 1nF 4 5 9 999µF 0 001µF 4 5 99 99µF 0 01µF 4 5 999 9µF 0 1µF 4 5 9 999mF 0 001mF 10 DC CURRENT Range Model Resolution Accuracy 600 0µA MP730007 MP730008 0 1µA 1 0 3 6000µA MP730007 1µA 1 0 3 60 00mA MP730007 MP730008 0 01mA 1 0 3 600 0mA MP73000...

Страница 8: ... ELECTRICAL ELECTRONIC EQUIPMENT These symbols indicate that separate collection of Waste Electrical and Electronic Equipment WEEE or waste batteries is required Do not dispose of these items with general household waste Separate for the treatment recovery and recycling of the materials used Waste batteries can be returned to any waste battery recycling point which are provided by most battery ret...