FS
17
Innovation. Quality. Performance. Best in Industry. Worldwide.
Restarting after Activation of Interlocks
The Interlocks are located inside the laser head assembly and in both the X- and Y-axis bellows and work as a
precautionary measure during regular operations. If the front access panel is opened during operation, the system
will pause motion and close the shutter. If the X- or Y-axis bellows constrict the cable, the system will pause
motion and close the shutter. Operators may continue the job file after the activation of the Interlocks by
following these instructions.
1. Correct the Interlock connection or miscommunication.
a. Close and secure the front access panel.
b. Determine the cause for the constriction on the Y-axis bellows, correct or replace, and press Restart to clear
the Y-axis constriction.
c. Remove the object that crossed the light curtain and correct or replace any portion of the X-axis bellows as
needed.
Routers * Lasers * Plasma * WaterJets * Knife Cutters
www.MultiCam.com v. 11 10