3.5 Insulation Resistance Measurement (Except PV System) 

1) Confirm the measuring switch  MEASURE  is off. 

2) Set range switch according to the rated voltage to be measured. 

  (Reference) 

    In case of rated circuit voltage 100V, set the range switch to [125V]. 

    In case of rated circuit voltage 200V, set the range switch to [250V]. 

    In case of rated circuit voltage 400V, set the range switch to [500V]. 

    In case of high voltage circuit equipment, set the range switch to [1000V]. 

In case of insulation resistance measurement at the completion examination at low 

voltage circuit, set the range switch to [500V]. 

3) Confirm the display value is “0M

Ω

”, after short-circuited LINE probe and EARTH clip and 

pressed measuring switch on. 

4) In case that one end of the object to be measured is grounded, connect with clip at 

(EARTH) end. 

5) After confirmed HV lamp is not lightened by contacting (LINE) probe to the object to be 

measured and pressed measuring switch on, the bar graph on LCD is lightening step by 

step and the measured value will be displayed after all bar graph lightened.

 

 
 
 
 
 
 
 
 
 
 

3.6 AC Voltage Measurement 

1) 

Confirm the measuring switch  MEASURE  is off. 

Object to be measured 

(Insulation Resistance) Measurement 

Set ON 

In case of one end of load grounded

R L 

Содержание MIS-PV2

Страница 1: ...ated voltage in PV systems 4 Can read the displayed value in the dark by LED back light of LCD 5 Auto power off function enables min power consumption in case of forgetting switch power off 6 Convenie...

Страница 2: ...ter opened the box check the appearance of instrument and confirm the accessories are contained 2 Specifications 2 1 Insulation Resistance Measurement 1 Rating Range Rated Measuring Voltage Max Effect...

Страница 3: ...D with bar graph annunciator 13 Over Range OL mark on display Range Rated Measuring Voltage Max Effective Display Value Measuring Range Accuracy 125V 125V 20M First Effective Range 0 02M 10M Second Ef...

Страница 4: ...on 2 2 AC Voltage Measurement ACV 1 Measuring Method Average value display 2 Measuring Range AC 0V 600V min resolution 0 1V 3 Accuracy 1 5 rdg 10dgt 2 3 General Specification 1 Operating Temperature...

Страница 5: ...e instrument is getting power on during pressing measuring switch By standing up this switch it will be locked as power on continuously Switch Switch Measuring Switch Display Name Plate for Rating Con...

Страница 6: ...ved in battery case 3 In case of not using for a long time remove all batteries as it may cause exhaustion and leakage of batteries WARNING 1 Misapplication of battery polarity may cause leakage of ba...

Страница 7: ...ghtened and the first measurement finished The first displayed value will be kept until finishing the second display By pressing data hold switch once the display will be hold and will be released by...

Страница 8: ...pletion examination at low voltage circuit set the range switch to 500V 3 Confirm the display value is 0M after short circuited LINE probe and EARTH clip and pressed measuring switch on 4 In case that...

Страница 9: ...ing your name address phone number and defect point 5 WARRANTY This instrument is sent out from our factory after the sufficient internal inspections but if you find any defect due to the fault in our...

Отзывы: