MULTI MEASURING INSTRUMENTS MIS-PV2 Скачать руководство пользователя страница 2

 
 
 
 
 
 
 
 
 
 
 

1. Before use 

1.1 Safety Symbol 
To use this instrument safely, the following symbols and contents are displayed on 

instrument body and instruction manual.

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

1.2 Caution for Operation 

! Do not drop and or throw the instrument at hard objects. 
! Do not store the instrument at the places with high temperature more than 60

o

  low temperature less than -20

o

C and high humidity and also, avoid the

 

direct rays of sun. 

! Do not apply chemicals like as thinner, acetone, etc. for cleaning. 
! Confirm the specifications/ratings in this manual and use the instrument within the rated values, 
 

 

1.3 Confirm the Accessories 

After opened the box, check the appearance of instrument and confirm the accessories are contained.

 

 

2. Specifications 

2.1 Insulation Resistance Measurement 

1) Rating 

 
 

 

Range 

Rated Measuring Voltage 

Max. Effective Display Value 

Center Display Value 

125V 125V 

20M

 0.5M

 

250V 250V 

50M

 1M

 

PVL 500V 

100M

 2M

 

PVH 1000V 

2000M

 50M

 

Showing careful operation. This symbol is displayed at the point where   
the references to instruction manual are required to protect operator & 
equipment. 
 
Showing the high voltage output more than 1000V. 
Touch to the terminal is dangerous. 
 

WARNING: Indicating the matters to be attended to avoid electrical shock and 
accidents which may affect danger to operator’s life and body. 
CAUTION: Indicating the matters to be attended to avoid damage of equipment 
and for general points of operation. 

Содержание MIS-PV2

Страница 1: ...ated voltage in PV systems 4 Can read the displayed value in the dark by LED back light of LCD 5 Auto power off function enables min power consumption in case of forgetting switch power off 6 Convenie...

Страница 2: ...ter opened the box check the appearance of instrument and confirm the accessories are contained 2 Specifications 2 1 Insulation Resistance Measurement 1 Rating Range Rated Measuring Voltage Max Effect...

Страница 3: ...D with bar graph annunciator 13 Over Range OL mark on display Range Rated Measuring Voltage Max Effective Display Value Measuring Range Accuracy 125V 125V 20M First Effective Range 0 02M 10M Second Ef...

Страница 4: ...on 2 2 AC Voltage Measurement ACV 1 Measuring Method Average value display 2 Measuring Range AC 0V 600V min resolution 0 1V 3 Accuracy 1 5 rdg 10dgt 2 3 General Specification 1 Operating Temperature...

Страница 5: ...e instrument is getting power on during pressing measuring switch By standing up this switch it will be locked as power on continuously Switch Switch Measuring Switch Display Name Plate for Rating Con...

Страница 6: ...ved in battery case 3 In case of not using for a long time remove all batteries as it may cause exhaustion and leakage of batteries WARNING 1 Misapplication of battery polarity may cause leakage of ba...

Страница 7: ...ghtened and the first measurement finished The first displayed value will be kept until finishing the second display By pressing data hold switch once the display will be hold and will be released by...

Страница 8: ...pletion examination at low voltage circuit set the range switch to 500V 3 Confirm the display value is 0M after short circuited LINE probe and EARTH clip and pressed measuring switch on 4 In case that...

Страница 9: ...ing your name address phone number and defect point 5 WARRANTY This instrument is sent out from our factory after the sufficient internal inspections but if you find any defect due to the fault in our...

Отзывы: