MULTI MEASURING INSTRUMENTS MIS-PV2 Скачать руководство пользователя страница 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Thank you for selecting our 4 range digital insulation tester 

MIS-PV2 for PV systems.   

Before using the instrument, read this instruction manual 

thoroughly and operate properly.   

Keep this manual carefully whenever you can refer if 

necessary. 

 

 

 

MAIN FEATURES 

 

(1) Multiple rating insulation resistance tester which can change 4 applied voltage by switch to 

select appropriate voltage for the object to be tested. 

(2) This digital multiple rating insulation resistance tester has big LCD window showing 

numerical value display and analog indicator which enable an easy reading. 

(3) 

Measurable insulation resistance according to the generated voltage in PV systems.

   

(4) Can read the displayed value in the dark by LED back light of LCD. 

(5) Auto power off function enables min. power consumption in case of forgetting switch power 

off. 

(6) Convenient structure design for the use – body cover can be contained to the bottom of 

instrument. 

(7) The output display lamp (HV lamp) serves functions as warning of outer loading voltage 

and or as confirming electric discharge with superior safety and wide functionality.   

(8) Data hold function enables measurements in any field & attitude. 

 

 

 

     
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

DIGITAL INSULATION TESTER FOR 
PHOTOVOLTAIC SYSTEMS 
WITH 4 RANGES 

Model

   

 

INSTRUCTION

 

MANUAL

 

MULTI MEASURING INSTRUMENTS CO.,LTD.

 

Akihabara Murai Bldg. 7F, 1 -26 Kanda Sakuma-cho, 
Chiyoda-ku, Tokyo 101-0025, JAPAN 
TEL: +81-3-3251-7013   
FAX: +81-3-3253-4278   
Website: http://www.multimic.com/ 
Email: [email protected]

 

Содержание MIS-PV2

Страница 1: ...ated voltage in PV systems 4 Can read the displayed value in the dark by LED back light of LCD 5 Auto power off function enables min power consumption in case of forgetting switch power off 6 Convenie...

Страница 2: ...ter opened the box check the appearance of instrument and confirm the accessories are contained 2 Specifications 2 1 Insulation Resistance Measurement 1 Rating Range Rated Measuring Voltage Max Effect...

Страница 3: ...D with bar graph annunciator 13 Over Range OL mark on display Range Rated Measuring Voltage Max Effective Display Value Measuring Range Accuracy 125V 125V 20M First Effective Range 0 02M 10M Second Ef...

Страница 4: ...on 2 2 AC Voltage Measurement ACV 1 Measuring Method Average value display 2 Measuring Range AC 0V 600V min resolution 0 1V 3 Accuracy 1 5 rdg 10dgt 2 3 General Specification 1 Operating Temperature...

Страница 5: ...e instrument is getting power on during pressing measuring switch By standing up this switch it will be locked as power on continuously Switch Switch Measuring Switch Display Name Plate for Rating Con...

Страница 6: ...ved in battery case 3 In case of not using for a long time remove all batteries as it may cause exhaustion and leakage of batteries WARNING 1 Misapplication of battery polarity may cause leakage of ba...

Страница 7: ...ghtened and the first measurement finished The first displayed value will be kept until finishing the second display By pressing data hold switch once the display will be hold and will be released by...

Страница 8: ...pletion examination at low voltage circuit set the range switch to 500V 3 Confirm the display value is 0M after short circuited LINE probe and EARTH clip and pressed measuring switch on 4 In case that...

Страница 9: ...ing your name address phone number and defect point 5 WARRANTY This instrument is sent out from our factory after the sufficient internal inspections but if you find any defect due to the fault in our...