WARNING 
Before changing batteries or fuse, remove all electrical input.   
 

6. REPAIR SERVICE 
   

 

When making requests for repair service, please bring the instrument directly to the 

    dealer. If this is impossible, however, send the instrument directly to our sales office. 
    When mailing this instrument, always pack it in its original or equivalent packing       
    material and pack together with name, address, telephone number and the warranty 
    documentation. 
 

● 

To ensure speedy and reliable repair, always include information as the type of 
failure and cause. 

● 

If required, always return accessories with the instrument. 

● 

When contacting us, provide the model number and serial number of your 
instrument. 

 
 
 
 

 

7. WARRANTY 
 

This instrument is sent out from our factory after the sufficient internal inspections 
but if you find any defect due to the fault in our workmanship or the original parts, 
please contact the dealer where you bought the instrument. 

 

The warranty period is 12 months from the date of purchase and the instrument 
shall be repaired at free of charge, provided that we judge the cause of defect is 
obviously resulted from our responsibility. 

 
 
GURANTEE REGULATIONS   
 
1.

 

This instrument is warranted for the operation under normal use for 12 months from 

    the date of purchase. 
2.

 

This warranty does not cover the following defects: 
a.

 

Defect caused from the improper use and operation. 

b.

 

Defect caused from the use, operation and storage beyond the original 
specifications, designs and conditions. 

c.

 

Defect caused from the renovations or repairs done by someone else than us or our 

    representatives. 
d.

 

Defect not caused from our responsibilities. 

 
       
                                                                                                                                                                                                                                         
                                                                                                                                                                                                                                                                                 

Содержание MCL-550D

Страница 1: ...anical electronic design Before you use your new instrument read this Instruction Manual completely and familiarize yourself thoroughly with all functions Keep this manual carefully to take out whenev...

Страница 2: ...operations WARNING POSSIBLE ELECTRICAL SHOCK This instrument is for the use of low voltage circuit Do not make measurements in the circuit more than AC 600V Before use check and confirm the voltage o...

Страница 3: ...f mode approx 10 minutes after the power switch on Operating temperature 0 to 40 80 RH non condensing Strange temperature 10 to 60 70 RH non condensing Power supply 1 5V AAA size R03 x2 Power consumpt...

Страница 4: ...where it is difficult to see the readings use the data hold switch Fig 1 Note Clamp around only one conductor of the circuit to be measured See Fig 1 When making the clamp measurements for high AC cur...

Страница 5: ...tion Connect the plug of red test lead into the V terminal and the plug of black test lead into the COM terminal Set the range selector switch to ACV range Contact the tips of the test leads to the ci...

Страница 6: ...to rain or moisture Do not operate the tester in the presence of flammable gases or fumes CAUTION To avoid damage to the tester disconnect test leads before changing functions Do not exceed the maximu...

Страница 7: ...e displayed CAUTION Be sure all voltage is turned OFF in the circuit before making diode test 5 REPLACEMENT OF BATTERIES When the battery voltage falls below a specified voltage value the B mark will...

Страница 8: ...ent out from our factory after the sufficient internal inspections but if you find any defect due to the fault in our workmanship or the original parts please contact the dealer where you bought the i...