MULTI MEASURING INSTRUMENTS M-2010 Скачать руководство пользователя страница 5

 

!

WARNING 

 

● 

To avoid electrical shock or damage, the measurement is limited to the circuit 
under 600V AC. 

Such voltages pose a shock hazard.   

● 

Never fail to keep the maximum 600A input to avoid electrical shock or damage.

● 

Never make measurements for uninsulated conductors or bus bars. 

 

 

 
 

5-2. Measurement of Voltage 

 
5-2-1. Measurement of AC Voltage 

 

① 

Set the power switch to "ON" position. 

② 

Connect the plug of red test lead into 

the “V” terminal and the plug of black   
test lead into the “COM” terminal. 

③ 

Set the range selector switch to “ACV~” 

range. 

④ 

Contact the tips of the test leads to the 

circuit under test. 

 

  Read the voltage value in the display.                                                          Fig.2   

 

  5-2-2. Measurement of DC Voltage 
 

① 

Set the power switch to "ON" position. 

  Connect the plug of red test lead into the “V” terminal and the plug of black test   

lead into the “COM” terminal. 

  Set the range selector switch to “DCV …” range. 

  Contact the tips of the test leads to the circuit under test. 

 

  Read the voltage value in the display.                                                           

                                                                                                                                   

 

 
 

 

 
 

 

 
 

 

 
 

 
 

Содержание M-2010

Страница 1: ...Before you use your new instrument read this Instruction Manual completely and familiarize yourself thoroughly with all functions With proper use and care your tester will give you years of satisfact...

Страница 2: ...nd etc Before operating this instrument familiarize yourself with all instructions outlined in this manual Always check to make sure that the function switch is set to the proper position When making...

Страница 3: ...LCD readout Auto power off The meter is set to power off mode approx 10 minutes after the power switch on Operating temperature 0 to 40 80 RH non condensing Strange temperature 10 to 60 70 RH non cond...

Страница 4: ...a range appropriate to the current to be measured Start the measurement at top range and then work down to lower range Clamp the conductor of the circuit at the center of CT Read the current value in...

Страница 5: ...onnect the plug of red test lead into the V terminal and the plug of black test lead into the COM terminal Set the range selector switch to ACV range Contact the tips of the test leads to the circuit...

Страница 6: ...rain or moisture Do not operate the tester in the presence of flammable gases or fumes CAUTION To avoid damage to the tester disconnect test leads before changing functions Do not exceed the maximum i...

Страница 7: ...d OFF in the circuit before making diode test 6 REPLACEMENT OF BATTERIES AND FUSE When the battery voltage falls below a specified voltage value the B mark will appear in the display If this occurs re...

Страница 8: ...this instrument always pack it in its original or equivalent packing material and pack together with name address telephone number and the warranty documentation To ensure speedy and reliable repair a...

Отзывы: