Sink Station 421914
Installation:
1. Find a suitable area close to water source for unit.
Mounting bracket should be installed approx. 5’ from
the floor. Level bracket and mark holes. Drill 9/32” holes
and install mounting anchors and screws in bracket.
2. Remove cabinet cover and hang cabinet on bracket.
Mark hole for lower cabinet screw. Remove cabinet and
drill 9/32” hole.
Install anchor and screw in lower cabinet hole. When
mounting unit, do not mount more than 5 feet from the
floor. Also, never mount your concentrate container
higher than the unit. Keyhole slots are also provided in
the cabinet back if the mounting bracket won’t be used.
3. Select a metering tip (see below), and insert into hose
barb on eductor body.
4. Supply tube should reach from hose barb on eductor
to bottom of the concentrate container. Cut supply tube
provided to length required.
Slide a ceramic weight over one end of tube and slide
a foot valve into the same end of the tube. (Prepare a
tube for each eductor.)
5. Push other end of supply tube over the hose barb/
metering tip on the eductor. (Repeat for all eductors.)
6. Place foot valve ends of supply tubes into concentrate
containers. REMEMBER TO CHECK FOOT VALVE
STRAINERS REGULARLY FOR CLOGGING: CLEAN
IF NECESSARY.
7. Longer tubes (4 feet) are used with the 3.5 GPM
eductor. Slide end of tube over eductor discharge outlet.
(Repeat for all eductors.) Direct hoses to the appropriate
sink basin. Secure using zip ties if necessary.
8. Replace cabinet cover. Guide supply tubes through
slots in sides of cabinet cover. Push the sides in, behind
the latch holes, to snap the cover in place. The two
screws provided may be installed in the holes in the
cabinet sides to prevent easy removal of cover.
2
Operation:
1. Connect water supply hose of at least 3/8” ID to
water inlet swivel. (Minimum 25 PSI pressure, with
water running, is required for proper operation.)
Connect opposite end of hose to water supply.
Turn water supply on.
2. Purge air from the system by depressing
the buttons briefly. There may be some water
discharge from the eductor vents until the air is
purged.
3. Push button to start flow of desired water/
concentrate solution, and hold until supply
tube is primed. Then push the button whenever
dispensing is desired, and release button to stop
flow of solution. If you wish to be able to lock the
button in the “on” position:
Depress button and slide button lock up. To
unlock, depress button and release.
4. It is essential that the discharge hose not be
obstructed. If discharge is restricted, water will
flow out the eductor vents. Do not start to operate
the dispenser with liquid in the discharge tube.
Tips:
15 Power Suds use purple tip (180:1)
10 Sanitizer use pink tip (350:1)
Product rack:
Optional product rack is available, item no. 421098