background image

Sink Station 421914

Installation:

1. Find a suitable area close to water source for unit. 

Mounting bracket should be installed approx. 5’ from 

the floor. Level bracket and mark holes. Drill 9/32” holes 

and install mounting anchors and screws in bracket.

2. Remove cabinet cover and hang cabinet on bracket. 

Mark hole for lower cabinet screw. Remove cabinet and 

drill 9/32” hole.

Install anchor and screw in lower cabinet hole. When 

mounting unit, do not mount more than 5 feet from the 

floor. Also,  never  mount  your  concentrate  container 

higher than the unit. Keyhole slots are also provided in 

the cabinet back if the mounting bracket won’t be used.

3. Select a metering tip (see below), and insert into hose 

barb on eductor body. 

4. Supply tube should reach from hose barb on eductor 

to bottom of the concentrate container. Cut supply tube 

provided to length required.

Slide a ceramic weight over one end of tube and slide 

a foot valve into the same end of the tube. (Prepare a 

tube for each eductor.)

5. Push other end of supply tube over the hose barb/

metering tip on the eductor. (Repeat for all eductors.)

6. Place foot valve ends of supply tubes into concentrate 

containers.  REMEMBER TO  CHECK  FOOT  VALVE 

STRAINERS REGULARLY FOR CLOGGING: CLEAN 

IF NECESSARY.

7. Longer tubes (4 feet) are used with the 3.5 GPM 

eductor. Slide end of tube over eductor discharge outlet. 

(Repeat for all eductors.) Direct hoses to the appropriate 

sink basin. Secure using zip ties if necessary.

8. Replace cabinet cover. Guide supply tubes through 

slots in sides of cabinet cover. Push the sides in, behind 

the latch holes, to snap the cover in place. The two 

screws provided may be installed in the holes in the 

cabinet sides to prevent easy removal of cover.

2

Operation:

1. Connect water supply hose of at least 3/8” ID to 

water inlet swivel. (Minimum 25 PSI pressure, with 

water running, is required for proper operation.) 

Connect opposite end of hose to water supply. 

Turn water supply on.

2.  Purge  air  from  the  system  by  depressing 

the  buttons  briefly. There  may  be  some  water 

discharge from the eductor vents until the air is 

purged.

3.  Push  button  to  start  flow  of  desired  water/

concentrate  solution,  and  hold  until  supply 

tube is primed. Then push the button whenever 

dispensing is desired, and release button to stop 

flow of solution. If you wish to be able to lock the 

button in the “on” position:

Depress  button  and  slide  button  lock  up.  To 

unlock, depress button and release.

4. It is essential that the discharge hose not be 

obstructed. If discharge is restricted, water will 

flow out the eductor vents. Do not start to operate 

the dispenser with liquid in the discharge tube.

Tips:

15 Power Suds use purple tip (180:1)

10 Sanitizer use pink tip (350:1)

Product rack:

Optional product rack is available, item no. 421098