Connection diagram
7
1
2
3
A
6
4
5
The installation and assembly of electrical
equipment must be only carried out only by a skilled
Person! Otherwise fire danger or danger of an
electric shock exists!
Connect the supply voltage/frequency as stated on
the product label!
Warranty void if housing opened by unauthorised
person!
The electronic circuit is protected against a wide
range of external influences. Incorrect operating
may occur if external influences exceed certain limits!
1. Safety instructions
The device can be used in following applications: Illumination of
private and industrial areas, street and shop-window lightening,
regulation of air conditioning, flushing, motors, pumps, plants and
machinery as well as to simulate presence etc.
Operate the device in a dry room only.
The device is not qualified for security relevant tasks such as
emergency doors, fire protection equipment
2. Intended use
See device
AgSnO
2
IP 20 nach DIN EN 60529
-30° ... +55°
1 BSTU
2
4 kV
DIN EN 60730-1/DIN EN 60730-2-7
Ideal for modern lamps
Supply voltage
Contact material
Type of protection
Permitted ambient temperature
Mode of operation
Degree of contamination
Rated surge voltage
Standard
CFL, LED
3. Technical data
If required, date, time and daylight savings time mode can be
adjusted also by pressing
r
q
-buttons and confirmed with
s
.
The current date and time is already programmed and
European daylight savings time is activated.
Select the desired language by pressing
r q
-buttons and confirm it by pressing
s
.
(Remark: By pressing
t
you move one step backwards from the current position)
Press
s
/
t
button to wake it up.
The time switch is delivered in sleep-mode, the display is switched off.
4. Initial operation
f
OK
f
0
12
24
19.10.2020
9:28
00
f
OK
f
0
12
24
f
OK
f
0
12
24
f
OK
f
0
12
24
f
OK
f
0
12
24
MONday
PROGRAM
Adjustments
OPTIONs
END
PROGRAM
New
PROGRAM
query
PROGRAM
edit
PROGRAM
delete
LN
PROGRAM
Simulation
PROGRAM
END
Date-time
Summertime
Astro
Data
language
N
factory
defaults
END
counter
pin-code
extra
switching time
cycle
random
END
5. Menu overview
Current state is based on a switching time with cycle function.
L
Element within sub-menu “program delete”.
Z
Current state is based on a switching time with pulse function.
I
Current state is based on a manual over-ride. The state is permanent until terminated manually.
P
Current state is based on a manual over-ride. The state will be cancelled with the next programming step.
H
Standard programming step
U.
Days of the week Monday, Tuesday, ... Sunday; The underscores indicate if the program is active for the days above.
1234567
Channel is switched OFF
y
Channel is switched ON
x
6. Symbol legend
2. To confirm the selection or the entered data.
1. To activate the time switch when operated without power supply.
f.
2. Automatic-mode: A push longer than 3 sec. = Permanent switching status.
1. Automatic-mode: To switch the channel ON or OFF until the next programming step occurs.
B
A
2. To scroll through a choice.
1. To adjust the flashing digit.
2. To revert to the beginning of the current (sub-) menu.
f.
1. To access the Enter-mode (program, adjustments, options) from the automatic-mode.
7. Key function
With
r
q
the choice changes from
END
to
ConTinue.
By confirming
ConTinue
mit
s
the time switch returns to the beginning of the current
(sub-) menu.
After completion of a (sub-) menu confirming
END
with
s
will return the device
into the automatic-mode.
To revert one step or one level back while in the Enter-Mode press
t
.
The time switch is programmable without external power supply after pressing
the
s
-button.
8. Handling advice
By pushing -buttons a manual switch of the
channels take place. The resulting switching status is
marked with the hand-symbol and remains until the
next programming step occurs (temporary over-ride).
H
9. Channel ON / OFF
10. Permanent
P
By pressing the corresponding channel button for
more than 3 sec. the channel is permanently switched
ON or OFF. The status remains until the next manual
switching occurs (> 3 sec.) (permanent over-ride).
f
OK
f
0
12
24
19.10.2020
9:28
00
f
OK
f
0
12
24
f
OK
f
0
12
24
f
OK
f
0
12
24
f
OK
f
0
12
24
MONday
PROGRAM
PROGRAM
NEw
channel A
Standard
OK
M
f
OK
f
0
12
24
PROGRAM
11. b) Standard weekly program
Standard
f
OK
f
0
12
24
Program
new
f
OK
f
0
12
24
channel ...
OK
M
Permanent
END
oN
cYcLe
off
PULSe
END
Monday
yes
tuesday
yes
wednesday
yes
thursday
yes
Friday
yes
Saturday
no
Sunday
No
1 2 3 4 5 6 7
Time
hour
0
00
:
1 2 3 4 5 6 7
time
Minute
0
00
:
1 2 3 4 5 6 7
Next
Switching time
END
OK
OK
OK
M
If you want to proceed with programming, confirm
Next Switching
with
s
.
To leave the programming menu change with
r q
to
End
and confirm with
s
.
Adjustment of the time: Hours
r q
and
s
, Minutes
r q
and
s
.
...
Within this level you activate the days of the week (1…7) on which the switching time should happen. With
r q
-buttons you activate
yes
or deactivate
No
the corresponding date. Confirm each date with
s
.
For regular switching times choose
ON
or
OFF
with
r q
-buttons and confirm with
s
.
If you want to program a standard weekly switching time (
ON
/
OFF
) confirm
Standard
with
s
.
11. c)
Example for the programming of STANDARD switching times (
ON
and
OFF
)
N
Y
A
c
c
Current state is based on a switching time with astro function.
S
The time switch is locked; to unlock the device the PIN has to be entered.
11. a) Programming menu
channel B
End
Permanent
End
OK
M
OK
M
M
OK
t
r q
s
B
A
s
1. To activate Bluetooth when time switch is active.
www.hugo-mueller.de
Hugo Müller GmbH & Co KG, Karlstraße 90, DE-78054 VS-Schwenningen
[SC44.x1pro4]
SC 44.21 pro4
0
12
24
19.10.2020
MONTAG
9:28
00
B *
* depends on model
For the cycle function it is possibile to enter a periodic switching time. The time switch acts as a recycling timer and
switches between pulse (ON) and pause (OFF). The max. value for pulse and pause is 9:59:59 h:mm:ss.
If you haven’t defined and activated a cycle, the cycle function will not be available as switching time. Therefore you
have to activate and define at least one of the four cycles within menu
Options
and sub-menu
CyCLE
(point 13).
c
c
The pulse function provides you the opportunity of programming a switching time with a defined duration. As soon as the pulse-duration
has expired the time switch switches OFF automatically (the duration of the pulse is up to 59:59 mm:ss).
Define the duty cycle (
Pulse Minute
/
pulse Second
)
.
Choose
pulse
-Function.
Define the
on
time
(
Time hour
/
time Minute
).
Define the days of the week for your pulse switching time.
13. Cycle options
14. Impuls
You have the possibility to define 4 different Cycles. For these purposes choose menu
Options
and sub-menu
Cycle.
The different cycles
can be activated, defined or deactivated (the max. value for pulse or pause is 9:59:59 h:mm:ss):
c
The cycle is now offered within the programming menu.
Choose menu
Options
and sub-menu
Cycle
and confirm
with
s
.
Select with
r q
-buttons one out of the 4 cycles (Cycle 1 – 4) and confirm with
s
.
Activate the cycle by changing
No
to
yes
with
r q
-buttons and subsequent confirming with
s
.
Define duration of the pulse „
On time
“
(
r q
s
...).
Define duration of the pause „
Off time
“ (
r q
s
...).
Confirm
End
with
s
.
15. Permanent program
The permanent by date program (holiday program) is a permanently on or off status of the channel for the programmed dates. The
number of switching times is only limited by the total number of free memory locations.
18. Astro function
17. Priorities of the switching programs
Standard switching times, Special programs, Extra switching times and Permanent by date are
executed according to their corresponding priority (by channel and date).
All switching programs except Extra switching times, suspend all other switching programs with
lower priority:
Highest Priority
Manual over-ride Permanent (3 sec. push)
Permanent by date
Extra switching time
Within the menu
sETTINGs
you have the option to use the astro function for the different channels.
After activation you have the two options:
AsTro preprogrammed
YES
: There will be created an Astro-ON and an Astro-OFF switching time
with offset 00 for all weekdays.
AsTro preprogrammed NO
: The astro function is now available when programming a new
switching program for the selected channel.
The astro function allows you to switch the whole year through in relation to sunset and sunrise, e.g. for illumination purposes (
AsTro-On
with sunset and
AsTro-off)
with sunrise). While programming an astro programm step there will be no daytime (hh:ss) suggested. Instead of this you have to enter an offset.
Additionally, with
NIghT-Off
and
NIghT-On
can be defined a period for switching the time switch OFF / ON.
These programming steps are single switching times by date. Extra switching times do not disable switching programs with lower priority.
16. Extra switching time
Lowest Priority
Standard weekly program
c
If the astro function is activated, existing switching times for the selected channel are deleted.
19. Additional adjustments
Menu
Main menu
Application
Program query
Program delete
Date - time
Summertime
language
factory defaults
Counter
PIN-Code
Program
To query the programming steps and remaining memory locations.
Adjustments
Deletion of switching time(s). The program for all channels, single channels and
single programming steps within on channel can be deleted.
Program
Adjustment of date and time
Adjustments
Adjustment of the daylight saving time mode (ON/OFF)
Adjustments
Choice of languages
Reset to the state of delivery.
c
Date, time and switching program will be lost!
Adjustments
Options
Displays the hour counter and pulse counter for each channel and the time
switch itself.
Options
The time switch can be locked with a 4-digit PIN-Code. The code can be
adjusted, activated and deactivated. If you have forgotten the Code please
call customer service.
Program Simulation
Program
Simulation of switching time(s). You have the option to simulate the switching
times for a specific date/period.
20.
Programming via Bluetooth
Instruction Manual -
Time switch
en
PROGRAM
PROGRAM NEw
Channel A
/
B
STANDARD
...
The cycle switching time will be terminated by another switching time (
on
,
off
,
pulse
) or by another cycle switching time.
Options
...
cYcLe
cYcLe 1-4
PROGRAM
PROGRAM NEw
PROGRAM
PROGRAM NEw
Channel A
/
B
permanent
...
PROGRAM
PROGRAM NEw
channel A
/
B
extra switching
...
options
extra switching
eS yes
SAVE
Sunset
Sunrise
astRO oN
astRO off
night oFF
/
ON
AdjusTmenTs
Astro-Data
channel A
/
B
...
Channel A
/
B
STANDARD
...
BA SC44 pro4 HM; de,en, fr, it -24198- 2020.11V02
f
OK
f
0
12
24
19.10.2020
9:28
00
MONday
bt
Smartphone App
Windows App
f
OK
f
0
12
24
19.10.2020
9:28
00
MONday
WIN
APP
BT active
BT active
20. Programm with Bluetooth
3.
2.
1.
21. Assembly instructions
12. Cycle
L
~
+
N
~
-