MISG-IO-M

7    Technical Data

Strain Gauge Amplifier IO-Link

Page-9

Input

Strain gauge channel: 
 

Measuring unit: 

unitless

 

Sensor types: 

Strain gauge full bridge

 

Measurement range: 

freely adjustable inside a range of -32000...+32000

Note: 

other measuring units, ranges and sensor types are available on request

Possible sensors and measurement ranges:

Strain gauge full bridge: 

Measurement range: 

freely adjustable inside a range of -32000...+32000

(e. g. force/pressure) 

 

(measuring units freely selectable)

 

Supply voltage: 

3 V

 

Resistance: 

min. 1x 350 

Ω

 for max. 1x strain gauge full bridge

 

 

min. 2x 700 

Ω

 for max. 2x strain gauge full bridges

 

 

 (Connection of more full bridges is possible, but the

  

 

 necessary minimum resistance will rise in proportion.)

Note: 

other measuring ranges and sensor types are available on request 

Output

Interface: 

IO-Link

Signal level: 

0/24V (as per IO-Link specification) 

Performance Parameters

Measuring amplifier: 

Accuracy: 

  max. 0,05% of range + sensor error

 

Resolution: 

Strain gauge channel: 16 bit 

 

Filter setting strain gauge:  0,5 s

 

Switch-on delay:  

<5 s

 

Response time: 

20 ms

Supply

Voltage:  

24 VDC

Current: 

Standard: 

 <30 mA

 

Switching (SIO): 

max. 100 mA

 

Total current: 

max. 130 mA

Reverse voltage protection: 

Yes (no function, no damage)

Environmental Conditions

Operating temperature: 

-20...+80 °C

Storage temperature: 

-20...+85 °C

EMC: 

tested as per: 

EN 61000-6-2:2005

 

 

EN 61000-6-4:2007 + A1:2011

Cable length: 

max. 2 m (MISG-IO - sensor element)

 

max. 20 m (MISG-IO - IO-Link master)

Mechanics

Casing: 

Material: 

PBT GF30

 

Color: 

Black (other colors on request)

 

Flammability: 

UL94 HB

 

Dimensions: 

72x28x35 mm (without electrical connection)

Electrical connection: 

To  sensor: 

M12x1 socket, 5-pole, cable, 2 m

 

To evaluation: 

M12x1 plug, 4-pole

Fitting position: 

any

Geräteschutz: 

Protection class: 

at least IP65 (electronics)

 

PCB: 

completely potted

Weight: 

60 g

Dimensions: 

approx. 95x28x35 mm (plug connector M12x1 on both sides)

 

Содержание MISG-IO

Страница 1: ...MISG IO MISG IO M MISG IO Operating Manual Strain Gauge Amplifier IO Link Page 1 Strain Gauge Amplifier IO Link MISG IO Strain Gauge IO Link ...

Страница 2: ...eration 5 4 1 Function 5 4 2 Before Mounting 5 4 3 Product Label 5 4 4 Mounting 5 4 5 Electrical Start Up 5 4 6 Supply Voltage 6 4 7 Electrical Connection 6 4 8 Function Test Fault Detection 6 5 Fault Recovery 7 6 Maintenance Dismounting Return Cleaning Disposal 8 7 Technical Data 9 8 Dimensions 10 Strain Gauge Amplifier IO Link Page 2 ...

Страница 3: ...U Positive supply connection U Negative supply connection C Q IO Link 1 General Strain Gauge Amplifier IO Link Page 3 1 1 Information 1 2 Signs and Abbreviations Warning Noncompliance can cause injuries to persons and or the demolition of the device There can be a danger to life Attention Noncompliance can cause faulty device operation or lead to property damage Information Noncompliance can influ...

Страница 4: ...arry out the work described and recognize potential hazards independently Depending on the operating conditions other knowledge may also be required e g of corrosive media Risk of injury if qualification is insufficient Improper handling can lead to considerable property damage and injury The required tasks as described in this operating manual should only be conducted by qualified personnel with ...

Страница 5: ...onal to the force change and is transmitted by the IO Link interface as a digital signal 4 Start Up Operation Strain Gauge Amplifier IO Link Page 5 4 1 Function 4 2 Before Mounting 4 3 Product Label Example Art Nr Part number SN Serial number 4 4 Mounting Check the delivery for completeness and visible defects immediately after receipt If parts are missing or if you detect visible defects inform t...

Страница 6: ...onnection The listed information can occasionally deviate from the actual device values If this is the case please comply with the product label The product label always lists the current information for the specific device t The output signal must be proportional to the sensor signal If this is not the case it can be a sign of a wrong mounting position or a bad adjustment Please read under chapte...

Страница 7: ...nsor shield cable area e g frequency converter remove interference source Operating temperatures too high low Comply with specified temperatures as per operating manual No connection to IO Link interface Cable break Check cables IO Link interface defect Replace IO Link interface 5 Fault Recovery Note Unjustified reclamations can incur additional costs Check for correct operation after each system ...

Страница 8: ...sensor and IO Link interface connected to the MISG IO too have to be switched off and at dead voltage condition Only clean the device with a soft damp piece of cloth 6 4 Cleaning Warning The MISG IO measuring amplifiers are maintenance free Only the manufacturer is allowed to conduct repairs Before returning a device see chapter 6 4 To return a device use original packaging or similar To protect a...

Страница 9: ...evel 0 24V as per IO Link specification Performance Parameters Measuring amplifier Accuracy max 0 05 of range sensor error Resolution Strain gauge channel 16 bit Filter setting strain gauge 0 5 s Switch on delay 5 s Response time 20 ms Supply Voltage 24 VDC Current Standard 30 mA Switching SIO max 100 mA Total current max 130 mA Reverse voltage protection Yes no function no damage Environmental Co...

Страница 10: ...MISG IO M 28 24 72 95 35 Strain Gauge Amplifier IO Link Page 10 8 Dimensions in mm top view side view front view ...

Страница 11: ...MISG IO M Strain Gauge Amplifier IO Link Page 11 ...

Страница 12: ...MISG IO M Strain Gauge Amplifier IO Link Page 12 Subject to change version 44 175 ...

Отзывы: