Muller MISG-IO Скачать руководство пользователя страница 4

MISG-IO-M

i

!

!

!

!

!

3    Safety Instructions

Strain Gauge Amplifier IO-Link

Page-4

3.1    Intended Use

Please select the correct strain gauge amplifier regarding function and equipment before mounting, start-
up and operation.

Further important safety instructions are in the individual chapters.

Warning

The MISG-IO has been designed and constructed solely for the intended use described here and may only be 
used in this way.

The technical specifications as described in this operating manual are mandatory. Inappropriate handling or operating 
the device outside of its technical specifications requires an immediate shutdown and inspection by the manufacturer.

When the device is transported from a cold into a warm environment, condensation can cause a device malfunction. 
Wait for device temperature and room temperature to equalize before a new start-up.

The manufacturer shall not be liable for claims of any kind based on operation contrary to the intended use.

Warning

3.2    Personnel Qualification

For mounting and start-up of the MISG-IO the personnel will have to be familiar with the applicable country-specific 
regulations and directives and have the required qualifications. They must have knowledge of measurement and 
control technology, be familiar with electrical circuits, be able to carry out the work described and recognize potential 
hazards  independently.  Depending  on  the  operating  conditions,  other  knowledge  may  also  be  required,  e.g.  of 
corrosive media.

Risk of injury if qualification is insufficient

Improper handling can lead to considerable property damage and injury.

- The required tasks as described in this operating manual should only be conducted by qualified
    personnel  with the qualifications described below.

- Keep unqualified personnel away from hazardous areas.

3.3    Special Hazards

Please comply with your country-specific norms and regulations (e.g. standards). In the case of special 
applications, please comply with the relevant norms and regulations.

Non-compliance can cause heavy injuries and property damage!

Electrostatic discharge (ESD) protection is required.
The proper use of grounded worktops and personal wristbands is required when working with open 
circuits (PCBs) to prevent damage to sensitive electronic components caused by electrostatic discharge.

Do not use this device in safety or emergency stop installations. Improper use of the device may result in 
injury.

Danger to life due to electric current. If live parts are touched, there is an immediate danger of death.

Installation and mounting of electrical equipment may only be carried out by qualified electricians.

Operation with a defective power supply unit (e.g. short-circuit from mains voltage to output voltage) can 
cause life-threatening voltages on the unit.

Warning

Warning

Warning

Danger

Содержание MISG-IO

Страница 1: ...MISG IO MISG IO M MISG IO Operating Manual Strain Gauge Amplifier IO Link Page 1 Strain Gauge Amplifier IO Link MISG IO Strain Gauge IO Link ...

Страница 2: ...eration 5 4 1 Function 5 4 2 Before Mounting 5 4 3 Product Label 5 4 4 Mounting 5 4 5 Electrical Start Up 5 4 6 Supply Voltage 6 4 7 Electrical Connection 6 4 8 Function Test Fault Detection 6 5 Fault Recovery 7 6 Maintenance Dismounting Return Cleaning Disposal 8 7 Technical Data 9 8 Dimensions 10 Strain Gauge Amplifier IO Link Page 2 ...

Страница 3: ...U Positive supply connection U Negative supply connection C Q IO Link 1 General Strain Gauge Amplifier IO Link Page 3 1 1 Information 1 2 Signs and Abbreviations Warning Noncompliance can cause injuries to persons and or the demolition of the device There can be a danger to life Attention Noncompliance can cause faulty device operation or lead to property damage Information Noncompliance can influ...

Страница 4: ...arry out the work described and recognize potential hazards independently Depending on the operating conditions other knowledge may also be required e g of corrosive media Risk of injury if qualification is insufficient Improper handling can lead to considerable property damage and injury The required tasks as described in this operating manual should only be conducted by qualified personnel with ...

Страница 5: ...onal to the force change and is transmitted by the IO Link interface as a digital signal 4 Start Up Operation Strain Gauge Amplifier IO Link Page 5 4 1 Function 4 2 Before Mounting 4 3 Product Label Example Art Nr Part number SN Serial number 4 4 Mounting Check the delivery for completeness and visible defects immediately after receipt If parts are missing or if you detect visible defects inform t...

Страница 6: ...onnection The listed information can occasionally deviate from the actual device values If this is the case please comply with the product label The product label always lists the current information for the specific device t The output signal must be proportional to the sensor signal If this is not the case it can be a sign of a wrong mounting position or a bad adjustment Please read under chapte...

Страница 7: ...nsor shield cable area e g frequency converter remove interference source Operating temperatures too high low Comply with specified temperatures as per operating manual No connection to IO Link interface Cable break Check cables IO Link interface defect Replace IO Link interface 5 Fault Recovery Note Unjustified reclamations can incur additional costs Check for correct operation after each system ...

Страница 8: ...sensor and IO Link interface connected to the MISG IO too have to be switched off and at dead voltage condition Only clean the device with a soft damp piece of cloth 6 4 Cleaning Warning The MISG IO measuring amplifiers are maintenance free Only the manufacturer is allowed to conduct repairs Before returning a device see chapter 6 4 To return a device use original packaging or similar To protect a...

Страница 9: ...evel 0 24V as per IO Link specification Performance Parameters Measuring amplifier Accuracy max 0 05 of range sensor error Resolution Strain gauge channel 16 bit Filter setting strain gauge 0 5 s Switch on delay 5 s Response time 20 ms Supply Voltage 24 VDC Current Standard 30 mA Switching SIO max 100 mA Total current max 130 mA Reverse voltage protection Yes no function no damage Environmental Co...

Страница 10: ...MISG IO M 28 24 72 95 35 Strain Gauge Amplifier IO Link Page 10 8 Dimensions in mm top view side view front view ...

Страница 11: ...MISG IO M Strain Gauge Amplifier IO Link Page 11 ...

Страница 12: ...MISG IO M Strain Gauge Amplifier IO Link Page 12 Subject to change version 44 175 ...

Отзывы: