OVEN VENTING INSTRUCTIONS
Residential Model Wood-Fired Ovens
OVERVIEW
Your Mugnaini wood-fired oven has been listed to the UL Standard for Safety for Fireplace Stoves,
UL 737 8th edition.
These requirements cover fireplace stoves that are freestanding assemblies having fire chambers intended
to be operated open to the room with the door either open or closed.
Ovens covered by these requirements are intended for attachment to a residential chimney capable of being
used for use with solid wood or coal fuels.
Mugnaini wood-fired ovens are intended for installation in accordance with the Standard for Chimneys,
Fireplaces, Vents and Solid Fuel Burning Appliances, NFPA 211.
CONDITIONS OF ACCEPTABILITY
• The wood-burning oven is not provided with a chimney system. The oven must be connected to any
listed chimney assembly.
• The chimney assembly must be installed in accordance with NFPA 211 Standard for Chimneys.
• The chimney diameter size is 8”.
• Factory-built chimneys or clay flue liners are acceptable.
• The chimney must have at least 36” of vertical rise.
• The oven is not designed to support the weight of a chimney length greater than 36” without
additional support. Failure to properly support the chimney pipe may damage the oven and void your
warranty. Follow chimney manufacturer’s installation instructions for proper chimney support.
• Chimney must terminate to an approved chimney cap with spark arrestor (screen mesh).
• Single wall and B-type vent pipes are NOT acceptable for this type if appliance.
• DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.
• CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION
IN YOUR AREA.