• When the LP tank is enclosed; it must be ventilated by openings on the sides, back and floor of
the enclosure. Each opening must have a total area of no less than 10 square inches. Keep the
ventilation openings for the LP tank free and clear from debris.
• Check the gas supply line for damage before each use. Check for leaks after every tank change.
NEVER check for leaks using a match or open flame.
• Do not use a tool to connect a LP tank. Damage resulting in an explosion hazard may occur.
• Always handle LP tanks with care. Do not drop or bump against sharp objects.
• When disconnecting and/or transporting a LP tank, always close the shut-off valve and cover the
connector. Always keep a LP tank in the upright position. Keep it away from any sources of high
heat.
• Never fill and LP tank beyond 80 percent full (by weight).
• Unused or extra LP tanks must be stored outdoors in a well-ventilated area out of the direct
sunlight and sources of high heat, flames or sparks. Keep out of reach of children. Do not store
additional LP tanks under the oven.
• Always close the shut-off valve on the LP tank when the appliance is not in use.
• A LP cylinder not connected for use shall not be stored in the vicinity of this or any other
appliance.
• If the outdoor grill is stored indoors, the LP tank must be disconnected and removed from the
appliance.
• If the above instructions are not followed exactly, a fire or explosion causing death or serious
injury may occur.
Steps to connect propane tank to oven
1.
Check the gas connector from the pizza oven and the LP tank connector. Make sure no dirt, bugs
or debris has accumulated inside. If there is debris inside, brush it out with a soft bristled brush
or a blast of air.
2.
Place the LP tank in position under the oven.
3.
Make sure the gas shut-off valve on top of the LP tank is completely closed.
4.
Insert the hose connector with pressure regulator into the valve
outlet. Tighten the plastic collar firmly into place. Hand tighten only
– do not use tools. Ensure the pressure regulator is level and
positioned per the photo.
5.
After hose connector installation, open the shut-off valve slowly.
Keep turning until the shut-off valve is fully open. Use a spray bottle
filled with a soapy solution to test all the gas connections for leaks.
If the solution bubbles, there is a leak. Close the shut-off valve and
have the gas line repaired by a qualified service technician.
6.
Close the shut-off valve until you are ready to use the oven.