![Mugnaini PICCOLO 60 Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/mugnaini/piccolo-60/piccolo-60_instructions-for-installation-use-and-maintenance-manual_1853613008.webp)
8
INSTALLATION, USE AND MAINTENANCE MANUAL
INSTALLATION INSTRUCTIONS
The
Piccolo 60/75 Outdoor Gas Fired Pizza Oven
comes from the factory fully assembled, tested and
equipped for use with either LPG (liquid propane gas) or Natural Gas. The gas type can be verified by
looking under the oven to check the label on the burner.
Basic Requirements for a Safe Installation
•
The oven must be installed outdoors and operated on a hard, flat and level surface.
•
Not for use under an over hang, pergola, balcony or other overhead obstruction.
•
When using the steel stand, installation on a non-combustible surface is allowed.
•
Install only in a well-ventilated draft free location.
•
Ensure adequate clearance around oven and chimney cap.
•
The oven must be cured first before use!
____________________________________________________________
Natural Gas Connection
The natural gas supply line needs to be installed by a qualified technician: follow all local codes and
check for leaks.
DO NOT ATTEMPT FIELD CONVERSIONS FROM LPG TO NATURAL GAS OR FROM NATURAL GAS TO LPG.
•
The natural gas supply line must terminate with a gas shut-off valve.
•
The connector pipe between the gas shut-off valve and the pizza oven can be either an approved
flex line or rigid pipe.
____________________________________________________________
Liquid Propane Gas Connection (propane tank)
The propane tank must be constructed and marked in accordance with the specifications for LP-gas
tanks of the U.S. Department of Transportation (DOT) or the National Standard of Canada,
CAN/CSAB339, tank, Spheres and Tubes of the Transportation of Dangerous Goods.
DO NOT ATTEMPT FIELD CONVERSIONS FROM LPG TO NATURAL GAS OR FROM NATURAL GAS TO LPG.
•
Use only a U.S. DOT or CSA approved LP gas supply tank. The LP tank must include a collar to
protect the tank valve and a shut-off valve. The cylinder supply system must be arranged for
vapor withdrawal and provided with a listed overfilling prevention device.
•
Never use a dented or rusty LP tank. If there is any question as to the soundness of the tank,
have it checked by your LP gas supplier. Never use a tank with a damaged or defective shut-off
valve.
• Use only the type 1 connector, hose and regulator assembly supplied with the Piccolo 60
Outdoor Gas Fired Pizza Oven.