Parts

HG-8 COLD CLIMATE FLUSHING SYSTEM

ID PART #

DESCRIPTION

1

546787

Composite or Cast Iron Vault Lid

2

546799

HG-8 Plate Rest

3

546785

2" Foam Insulation Pad

4

790015

21" Ø Below-Grade Vault

5

HG-A102L

9-Volt Lithium Battery

6

546779

1" Valve & Meter 
Replacement Assembly

7

700014

Reinforcing Ring

8

546025

1" Coiled Tubing Assembly

9

HG-A119

320 Inline Dechlorination Assembly

10 HG-FP100

Thermal Control Valve

11 546138-100

1" Backflow Double Check Valve

12 014215 330N

1" Meter Coupling

13 024265 1 330N 1" Ball Angle Meter Valve

14 014210 1 330N 1" Meter Coupling

15 700507 Flow

U-Bar w/ Hole for FP

16 HG-FP100

Thermal Control Valve

17 5461219

Coated Steel Mounting Platform

18 700507

U-Bar

19 546596

Latching Solenoid

20 HG-FP108C

Molded Freeze Adapter / Gasket

21 HG-11010

1" Flow Control Valve

22 HG-V139

3/8" Poly Tubing

REPLACEMENT PARTS

1

2

3

4

5

6

7

8

15

16

21

20

19

22

18

17

9

10

14

13

11

12

Содержание Hydro-Guard HG-8 Cold Climate

Страница 1: ...by Mueller Co only and may not be applicable for any other use 2 DO NOT exceed the pressure ratings of any components or equipment Exceeding the rated pressure may result in serious injury and or pro...

Страница 2: ...e storm pond etc The meter and flushing assembly can be raised for maintenance and repair and then lowered back down into the box below the frost line A medium density foam insulation pad freeze prote...

Страница 3: ...w existing grade and ensure the meter lid is level with existing grade 7 Place the pit in the excavated area and connect the inlet piping Hand tighten the fitting to the pit then turn two full turns w...

Страница 4: ...te the device list can be found on the label located on the back of the controller housing with the designation Default name The App will indicate that it is in the process of connecting 8 Once the de...

Страница 5: ...controller 3 Make sure no water is inside battery compartment 4 Screw the NODE rear body back onto front half NOTE Make sure that seal marker on rear half of the NODE lines up with front half ensuring...

Страница 6: ...time in 15 minute increments 4 Press RIGHT ARROW key to add an additional START TIME to program displayed The start time number is shown in upper left corner of display 5 Press PRG key to add START T...

Страница 7: ...intenance If disassembly is necessary please follow the directions below Always close the curb stop before working on the unit Disassembly 1 Shut off water supply to the unit and remove the green hous...

Страница 8: ...or lack of connection Run a manual flush and confirm the solenoid plunger is kicking out and pulling back in by listening for a click Check connections for corrosion breaks or lack of connection Chec...

Страница 9: ...d until snug The following is a brief overview and introduction to our options Integrated Sample Station The HG 8 Cold Climate Sub Surface Discharge Unit features a Sample Port quick connect that allo...

Страница 10: ...ine Dechlorination Assembly 10 HG FP100 Thermal Control Valve 11 546138 100 1 Backflow Double Check Valve 12 014215 330N 1 Meter Coupling 13 024265 1 330N 1 Ball Angle Meter Valve 14 014210 1 330N 1 M...

Страница 11: ...11 Notes HG 8 COLD CLIMATE FLUSHING SYSTEM...

Страница 12: ...are liable only for their own acts and omissions and not those of each other MWP brands include Mueller Echologics Hydro Gate Hydro Guard HYMAX Jones Krausz Mi Net Milliken Pratt Pratt Industrial Sing...

Отзывы: