Freeze Protection 

The Hydro-Guard® Direct Discharge 
Unit (HG-2) can be upgraded to 
include freeze protection via a 
thermal control valve to help 
prevent the unit from freezing at 
colder temperatures. 

Dechlorination

All Hydro-Guard® Units are 
equipped with a dechlorination 
system. Dechlorination takes place 
as a portion of the discharged 
water passes through a housing 
containing either sodium sulfite 
or ascorbic acid tablets. This 
action creates a concentrated 
dechlorination solution that 
then mixes with the non-directly 
treated portion of the discharge to 
effectively dechlorinate the entire 
discharge volume. This option 
is available for the HG-2 Direct 
Discharge Unit. 

The following is a brief overview 
and introduction to Hydro-Guard® 
Options.

Sample Station

A standard feature on the HG-2 Low 
Profile Direct Discharge Unit is the 
sample port, which allows Hydro-
Guard's Portable Sample Valve 
(Part# HG-S 1167) to attach to the 
sample port to obtain a sample. 
Slip off the sanitary blue cap, attach 
the quick-connect adaptor, open 
the valve and collect your sample. 
You may wish to run a brief manual-
mode flush prior to the collection 
in order to ensure water indicative 
of the main-line water quality is 
being sampled. Generally a two-
minute flush is sufficient. Track your 
residual levels and alter flushing 
frequency and/or duration in order 
to maximize water conservation.

Rock Enclosure  

The Hydro-Guard® Direct Discharge 
Unit (HG-2) can be upgraded to 
include a rock enclosure for those 
areas that might desire or require it. 

HYDRO-GUARD® FEATURES, OPTIONS AND UPGRADES 

Options and Upgrades 

Содержание Hydro-Guard HG-2

Страница 1: ...ipment and follow all recommended procedures when installing operating and maintaining the Hydro Guard Automatic Flushing Device 5 Replace worn or defective parts with OEM parts and check your battery...

Страница 2: ...g it is connected on one side to the utility s service line trench Remove any debris that might create uneven pressure on the Unit Compact the bottom of the hole in order to minimize settling after in...

Страница 3: ...3 Launch the application on your Smartphone or Tablet 4 Associate the controller with your phone by tapping the Add a Controller button 5 The app will now ask what type of Bluetooth device you would l...

Страница 4: ...ontroller The controller home screen has the option to manually run the system fully program the controller with up to 8 start times and 8 independent programs and to turn the device off permanently o...

Страница 5: ...tore from a previous backup from the browser or the mobile application Manual Operation Allows you to manually run a station for up to 12 hours or run a complete program manually The status of the rai...

Страница 6: ...to other parts of any installation of which this product is part The warranty shall not apply to any equipment which is found to have been improperly installed set up or used in any way not in accord...

Страница 7: ...Insert battery batteries into battery tray and connect the battery connector to controller 3 Make sure no water is inside battery compartment 4 Screw the NODE rear body back onto front half NOTE Make...

Страница 8: ...e program 4 Press PRG key to set days to flush for a different program if desired 5 Press RETURN ENTER key to proceed to next programming function or allow controller to return to Idle mode Manual Flu...

Страница 9: ...The following is a brief overview and introduction to Hydro Guard Options Sample Station A standard feature on the HG 2 Low Profile Direct Discharge Unit is the sample port which allows Hydro Guard s...

Страница 10: ...lilting slightly on its end Once the retaining pin located in the opposite end of the housing is clear of the cover lilt upward to remove the cover 3 Use the sample port connection to bleed off resid...

Страница 11: ...e flow The water pressure Is too high and the solenoid will not close Try this Correction Run a manual flush for 1 minute Change batteries Check connections for corrosion breaks or lack of connection...

Страница 12: ...1 Bushing Machined 9 HG 14016 1 x 4 PVC Nipple 10 HG 01100 Cap 11 HG S258 Controller Clip 12 HG 13140 2 90 Elbow TxT 13 HG 13210 Controller Support Clamp 14 HG S138 2 Male Union Assembly 15 HG 01157...

Страница 13: ...Coupling SxT 10 HG 02108 2 x 7 SxT PVC 11 HG 02112B Support Bracket 12 HG S139 RP2 Sub Assembly 13 HG 02112 Brace 14 HG 021128 Support Bracket 15 HG S255 Latching Solenoid Assembly 7 16 HG V117H Valve...

Страница 14: ...14 NOTES...

Страница 15: ...15 NOTES...

Страница 16: ...cts Inc All Rights Reserved The trademarks logos and service marks displayed in this document are the property of Mueller Water Products Inc its affiliates or other third parties Products marked with...

Отзывы: