Mueller HG-1 Скачать руководство пользователя страница 5

5

Programming Unit

HG-1 FLUSHING SYSTEM

NOTE:
– Pr or – key when running 
in MANUAL FLUSH mode will modify 
FLUSH TIME for that station.
– Pressing the button when a 
station is running in manual 
watering will stop flush on the 
current station and advance to the 
next station.
– Pressing the button when a 
station is running in manual 
watering will stop the flush on the 
current station and revert to the 
previous station.

Turn System Off

To turn off controller, press 

RETURN / ENTER

 key button 

until icon resembling water spray 
and 

OFF

 is displayed on screen. 

To return controller to auto 
programming mode, press 

RETURN 

/ ENTER

 key. The controller 

will immediately return to auto 
programming mode and will display 
time and battery life indicator.

NODE Quick Check

This circuit diagnostic procedure 
can quickly identify “shorts” 
commonly caused by faulty 
solenoids or when bare common 
wire touches a bare station control 
wire. To initiate 

NODE Quick 

Check

 procedure:

1. 

From Idle Mode, press and hold 

+

LEFT ARROW

, and 

RIGHT 

ARROW

 keys.

2.

 Display will show all segments. 

Release keys.

3.

 Press 

+

 key to initiate 

NODE 

Quick Check

 test.

4.

 Controller will then activate 

flushing unit for 1 second to 
verify operation.

Setting Flushing Days
1.

 Press 

RETURN / ENTER

 key 

until 

CALENDAR

 icon is displayed. 

The program letter (A, B, or C) 
will be displayed. Arrows point 
at specific days of week in which 
flushing will occur.

2.

 Press 

LEFT

 or 

RIGHT ARROW

 

to scroll though days.

3. 

Press 

+

 key to activate that day 

for program displayed, or 

 key to 

cancel watering for that day. The 
arrow will show on flushing days 
for active program.

4.

 Press 

PRG

 key to set days to 

flush for a different program, 
if desired.

5.

 Press 

RETURN / ENTER

 key 

to proceed to next programming 
function, or allow controller to 
return to idle mode. 

Manual Flushing

Manual flushing allows user to test 
the Hydro-Guard unit or a program 
for a specified run time.
Make sure controller is in Idle Mode.

1. 

Press and hold 

RIGHT ARROW

 

until 

HAND

 icon is displayed. The 

station number (always #1) will 
be displayed in lower left side of 
display along with RUN TIME.

2. 

Use the 

LEFT

 or 

RIGHT ARROW

 

to select #1 station if not already 
displayed, and 

+

 or 

 key to set 

manual flushing time.

3.

 To manually activate a program, 

press 

PRG

 key. Program letter (A, 

B, or C) will show on screen. If a 
different program is needed, press 

PRG

 key until desired program 

is displayed.

4.

 To stop 

MANUAL FLUSHING

 

cycle press – key until time is 
reduced to zero.

5.

 Press 

RETURN / ENTER

 key 

to proceed to next programming 
function, or allow controller to 
return to idle mode. 

Battery Life Indicator

Remaining battery life can be 
estimated from the battery life 
indicator shown on display. The 
NODE can operate using either a 
single 9-volt battery or using two 
9-volt batteries. Using two nine volt 
batteries will yield approximately 
twice the battery life of a single 
9-volt battery. The battery life 
indicator chart below shows an 
estimate of remaining battery life.

Full: 

100 - 60% remaining battery life

Med: 

60 - 25% remaining battery life

Low: 

25 - 0% remaining battery life

Replace battery immediately!

Resetting Controller

Resetting controller will erase 
current program data and restart 
controller. A reset does not, 
however, delete a program saved to 
permanent memory using the Easy 
Retrieve Memory feature to save a 
preferred program.

1.

 From Idle Mode, press and hold 

RIGHT ARROW

, and 

PRG

 keys.

2.

 After two seconds screen will go 

blank. Continue to hold keys.

3.

 12:00 will flash on display. 

Release keys.

4.

 The controller may show a 

countdown from 10 to 1 on 
display, and then 12:00 am will 
be shown flashing when reset is 
complete. The controller can now be 
reprogrammed.

Содержание HG-1

Страница 1: ...s manufactured by Mueller Co only and may not be applicable for any other use 2 DO NOT exceed the pressure ratings of any components or equipment Exceeding the rated pressure may result in serious injury and or property damage 3 Safety goggles and other appropriate protective gear should be used Failure to do so could result in serious injury HG 1 Automatic Flushing System Installation Instruction...

Страница 2: ...ttling after installation Place 57 stone then non compacted clean bedding material within the bottom of the hole 3 Slowly lower the Hydro Guard Unit into place pressing it firmly into the noncompacted bedding material until it is fully seated 4 Connect the utility s water system to the Hydro Guard Unit by means of the 2 threaded connection Ensure that the Unit is level before beginning the backfil...

Страница 3: ...ceed 120 psi the installation of a pressure reducing valve PRV is recommended Battery Life Will vary based on number of cycles per year operating pressure and temperature We recommend checking the battery every 6 months but in many cases you will get more life out of them HG 1 REQUIRES CONTROLLER The BL KR battery powered irrigation module communicates with the K Rain BL Application on a Smartphon...

Страница 4: ...partment 2 Insert battery batteries into battery tray and connect the battery connector to controller 3 Make sure no water is inside battery compartment 4 Screw the NODE rear body back onto front half NOTE Make sure that seal marker on rear half of the NODE lines up with front half ensuring a proper seal is created Also The NODE has non volatile memory which allows battery replacement without losi...

Страница 5: ...ng function or allow controller to return to idle mode Manual Flushing Manual flushing allows user to test the Hydro Guard unit or a program for a specified run time Make sure controller is in Idle Mode 1 Press and hold RIGHT ARROW until HAND icon is displayed The station number always 1 will be displayed in lower left side of display along with RUN TIME 2 Use the LEFT or RIGHT ARROW to select 1 s...

Страница 6: ...hamber 5 Reinstall chamber covers lower bracket to secure them and retighten two nuts securely 6 Follow instruction 8 above to reinstall Exterior Housing Cover and restore water supply to unit The HG 1 Unit is designed to operate unattended and with minimal need for service In the event it is necessary to service the flushing unit s control valve solenoid or any other below grade component or to l...

Страница 7: ... solenoid There is a hole in or debris around the diaphragm Try this Correction Run a manual flush for 1 minute Change batteries Check connections for corrosion breaks or lack of connection Check the adapters and solenoid for debris Run the electrical systems check Refer to valve troubleshooting for possible corrective measures PROBLEM CAUSE SOLUTION Controller does not flush as desired Water at m...

Страница 8: ...the bury depth of the main 2 valve The HG 1 offers a valve bury depth of approximately 16 with above ground electronics that can be powered by a 9 volt Lithium battery operational in temperatures as low as 20 F For additional freeze protection consider the HG 3 design The HG 3 18 to 108 bury is equipped with Mueller s patented freeze protection system The freeze protection system allows the water ...

Страница 9: ...ound Plate 7 HG 01141A Stainless Steel Housing Bracket 8 546025 15 PVC Housing Pipe 9 HG 123100 2 Valve 520 050 w Flow Control 10 HG 13101 Cam Lock Release System 11 546330 Splash Pad 12 or 13 HG 5292 NODE Controller Sub Assembly HGI BL Bluetooth Controller Sub Assembly PART PIPE MATERIAL HG1ARM2BRN018LPLG PVC HG1AIN2BRN018LPLG Brass HG1ARM2PVC018LPLG PVC HG1AIN2PVC018LPLG Brass 10 7 5 1 12 2 3 4 ...

Страница 10: ...10 Notes HG 1 FLUSHING SYSTEM ...

Страница 11: ...are liable only for their own acts and omissions and not those of each other MWP brands include Mueller Echologics Hydro Gate Hydro Guard HYMAX Jones Krausz Mi Net Milliken Pratt Pratt Industrial Singer and U S Pipe Valve Hydrant Please see muellerwp com brands and krauszusa com to learn more 2020 Mueller Water Products Inc All Rights Reserved The trademarks logos and service marks displayed in th...

Отзывы: