Mueller HG-1 Скачать руководство пользователя страница 4

4

Programming Unit

HG-1 FLUSHING SYSTEM

pressing 

or 

 keys. To change 

something not flashing, press 

LEFT

 or 

RIGHT

 

ARROWS

 until 

desired item is flashing.

Setting Date / Time
1.

 Press 

RETURN / ENTER

 key 

until 

CLOCK

 icon is displayed.

2.

 All 4 digits will be displayed 

representing the year. Use 

+

 or 

 

keys to change year. Press 

RIGHT ARROW

 key to proceed 

to setting month.

3.

  All 4 digits will be displayed 

with two digits on left flashing 
representing the 

MONTH

. Use 

+

 

or 

 key to change month. Press 

RIGHT ARROW

 key to proceed to 

setting 

DAY

.

4.

 Only two digits on right will be 

flashing, representing the 

DAY

Press 

+

 or 

 key to change day. 

Press 

RIGHT ARROW

 key to 

proceed to changing 

TIME

.

5.

 The 

AM / PM / 24

 time setting 

is shown flashing. Press 

+

 or 

 key 

to change to AM, PM, or 24-hour 
time. Press 

RIGHT ARROW

 key to 

proceed to setting the 

HOUR

.

6. 

All 4 numbers are shown with 

two numbers on the left flashing, 
representing the 

HOUR

. Press 

+

 

or 

 key to change the hour. Press 

RIGHT ARROW

 key to proceed to 

setting 

MINUTES

.

7.

 All 4 numbers are shown with 

two numbers on right flashing, 
representing 

MINUTES

. Press 

+

 or 

 key to change minutes. (Pressing 

RIGHT ARROW

 key will return to 

YEAR

 setting at step #2.)

8.

 Press 

RETURN / ENTER

 key 

to proceed to next programming 
function, or allow controller to 
return to idle mode. 

Setting Flush Sequence 
Start Times
1.

 Press 

RETURN / ENTER

 key 

until 

CLOCK

 icon is displayed.

2. 

The 

START TIME

 will be 

displayed flashing, along with the 
program letter (A, B, or C) and 

HG-1 BUILT-IN: (INTEGRATED)

NODE Programming Instructions
Batteries

The NODE uses standard 9-volt 
alkaline batteries to operate the 
control valve and program the 
controller. The controller can operate 
with one or two batteries installed. 
Under normal conditions, potential 
life is 1 year for a single battery. 

Battery Installation
1.

 Unscrew rear body of the 

NODE to gain access to battery 
compartment.

2. 

Insert battery / batteries into 

battery tray and connect the 
battery connector to controller.

3.

 Make sure no water is inside 

battery compartment.

4.

 Screw the NODE rear body back 

onto front half.

NOTE: Make sure that seal marker 
on rear half of the NODE lines 
up with front half, ensuring a 
proper seal is created. Also, The 
NODE has non-volatile memory, 
which allows battery replacement 
without losing program 
information.

Idle Mode – Waking Up

Normally the NODE display shows 
time and day, day of week, and 
battery life indicator. During a 
short period of inactivity the 
display will shut off to retain 
battery power Pressing any key will 
wake up the NODE to the Idle Mode.

Run Mode

When controller is operating a 
program, items shown on display 
will include station number (always 
“1”), program letter (A, B, or C), 
remaining runtime, and a blinking 
Rotor icon. 

Programming

The NODE has the capability to 
hold 3 programs (A, B, C) and 4 
start times per program. When 
programming, flashing portion 
of display can be changed by 

start time number (1, 2, 3, or 4) in 
the upper left of the display. Up to 4 
different start times can be set for 
each program.

3. 

Use 

+

 or 

 key to change 

START 

TIME 

for program displayed. Each 

press of key will change start time 
in 15-minute increments.

4.

 Press 

RIGHT ARROW

 key to 

add an additional 

START TIME

 to 

program displayed. The start time 
number is shown in upper left 
corner of display.

5.

 Press 

PRG

 key to add 

START 

TIME

 to a different program.

6.

 Press 

RETURN / ENTER

 key 

to proceed to next programming 
function, or allow controller to return 
to idle mode.

Setting Flush Duration Times
1. 

Press 

RETURN / ENTER

 key until 

HOURGLASS

 icon is displayed. 

RUN 

TIME

 will be displayed flashing. 

Also shown is program letter (A, B, 
or C) and active station # (always 
#1 – all other stations not used) on 
lower left side of display.

2.

 Press 

+

 or 

 key to change 

station 

RUN TIME

 from 1 minute to 

6 hours.

3.

 Press 

PRG

 key to add a 

RUN 

TIME

 to another program.

4. 

Press 

RETURN / ENTER

 key 

to proceed to next programming 
function, or allow controller to return 
to idle mode.

Содержание HG-1

Страница 1: ...s manufactured by Mueller Co only and may not be applicable for any other use 2 DO NOT exceed the pressure ratings of any components or equipment Exceeding the rated pressure may result in serious injury and or property damage 3 Safety goggles and other appropriate protective gear should be used Failure to do so could result in serious injury HG 1 Automatic Flushing System Installation Instruction...

Страница 2: ...ttling after installation Place 57 stone then non compacted clean bedding material within the bottom of the hole 3 Slowly lower the Hydro Guard Unit into place pressing it firmly into the noncompacted bedding material until it is fully seated 4 Connect the utility s water system to the Hydro Guard Unit by means of the 2 threaded connection Ensure that the Unit is level before beginning the backfil...

Страница 3: ...ceed 120 psi the installation of a pressure reducing valve PRV is recommended Battery Life Will vary based on number of cycles per year operating pressure and temperature We recommend checking the battery every 6 months but in many cases you will get more life out of them HG 1 REQUIRES CONTROLLER The BL KR battery powered irrigation module communicates with the K Rain BL Application on a Smartphon...

Страница 4: ...partment 2 Insert battery batteries into battery tray and connect the battery connector to controller 3 Make sure no water is inside battery compartment 4 Screw the NODE rear body back onto front half NOTE Make sure that seal marker on rear half of the NODE lines up with front half ensuring a proper seal is created Also The NODE has non volatile memory which allows battery replacement without losi...

Страница 5: ...ng function or allow controller to return to idle mode Manual Flushing Manual flushing allows user to test the Hydro Guard unit or a program for a specified run time Make sure controller is in Idle Mode 1 Press and hold RIGHT ARROW until HAND icon is displayed The station number always 1 will be displayed in lower left side of display along with RUN TIME 2 Use the LEFT or RIGHT ARROW to select 1 s...

Страница 6: ...hamber 5 Reinstall chamber covers lower bracket to secure them and retighten two nuts securely 6 Follow instruction 8 above to reinstall Exterior Housing Cover and restore water supply to unit The HG 1 Unit is designed to operate unattended and with minimal need for service In the event it is necessary to service the flushing unit s control valve solenoid or any other below grade component or to l...

Страница 7: ... solenoid There is a hole in or debris around the diaphragm Try this Correction Run a manual flush for 1 minute Change batteries Check connections for corrosion breaks or lack of connection Check the adapters and solenoid for debris Run the electrical systems check Refer to valve troubleshooting for possible corrective measures PROBLEM CAUSE SOLUTION Controller does not flush as desired Water at m...

Страница 8: ...the bury depth of the main 2 valve The HG 1 offers a valve bury depth of approximately 16 with above ground electronics that can be powered by a 9 volt Lithium battery operational in temperatures as low as 20 F For additional freeze protection consider the HG 3 design The HG 3 18 to 108 bury is equipped with Mueller s patented freeze protection system The freeze protection system allows the water ...

Страница 9: ...ound Plate 7 HG 01141A Stainless Steel Housing Bracket 8 546025 15 PVC Housing Pipe 9 HG 123100 2 Valve 520 050 w Flow Control 10 HG 13101 Cam Lock Release System 11 546330 Splash Pad 12 or 13 HG 5292 NODE Controller Sub Assembly HGI BL Bluetooth Controller Sub Assembly PART PIPE MATERIAL HG1ARM2BRN018LPLG PVC HG1AIN2BRN018LPLG Brass HG1ARM2PVC018LPLG PVC HG1AIN2PVC018LPLG Brass 10 7 5 1 12 2 3 4 ...

Страница 10: ...10 Notes HG 1 FLUSHING SYSTEM ...

Страница 11: ...are liable only for their own acts and omissions and not those of each other MWP brands include Mueller Echologics Hydro Gate Hydro Guard HYMAX Jones Krausz Mi Net Milliken Pratt Pratt Industrial Singer and U S Pipe Valve Hydrant Please see muellerwp com brands and krauszusa com to learn more 2020 Mueller Water Products Inc All Rights Reserved The trademarks logos and service marks displayed in th...

Отзывы: