Analog-to-Digital and Digital-to-Analog converters
The MTX-DIN modem has 2 independent, unbalanced analog inputs as well as 1 analog output.
Depending on the internal GSM module used (2G or 3G) there are several differences between them
which will be described in detail in the following sections.
Both analog inputs can be configured for measuring DC voltages in the range of 0 to 2.4V, or DC
currents in the range of 0-20mA. This is done with the jumper JPu1. The next figure shows its exact
location on the PCB (you must open the device enclosure to access it)
The following table shows the configuration of each analog input:
Mode
JPu1
ADC1 voltage, ADC2 voltage
JP 1-2: Open
JP 3-4: Open
ADC1 voltage, ADC2 current
JP 1-2: Open
JP 3-4: Closed
ADC1 current, ADC2 voltage
JP 1-2: Closed
JP 3-4: Open
ADC1 current, ADC2 current
JP 1-2: Closed
JP 3-4: Closed