![MTU 20V4000L63 Скачать руководство пользователя страница 23](http://html1.mh-extra.com/html/mtu/20v4000l63/20v4000l63_operating-instructions-manual_1852708023.webp)
2.5 Technical Data
2.5.1 20V 4000 L63 engine data, fuel optimized (TA-Luft)
Explanation:
DL Reference value: Continuous power
BL Reference value: Fuel stop power
A Design value
G Guaranteed value
R Guideline value
L Limit value, up to which the engine can be operated, without change (e.g. of power setting)
N Not yet defined value
- Not applicable
X Applicable
Refernce data
Engine model
20V 4000
L63
Application group
3A
Intake air temperature
°C
25
Charge-air coolant temperature
°C
40
Barometric pressure
mbar
1000
Site altitude above sea level
m
100
Table 4: Refernce data
Power-related data (power ratings are net brake power to ISO 3046)
Number of cylinders
20
Rated engine speed
A
rpm
1500
Mean piston speed
m/s
10.5
Continuous power as per ISO 3046
A
kW
2200
Mean effective pressure (pme) (continuous power ISO 3046)
bar
18.5
Table 5: Power-related data (power ratings are net brake power to ISO 3046)
General conditions (for max. power)
Number of cylinders
20
Relative air humidity
A
%
30
Intake air temperature
A
°C
25
Intake air temperature, min.
L
°C
20
Intake air temperature, max.
L
°C
30
Mixture temperature after mixture cooler
A
°C
50
Ambient intake depression, max.
L
mbar
3.0
Pressure loss over air filter, max.
L
mbar
30
Exhaust back pressure, max.
L
mbar
60
MS150059/02E 2013-10
| Product Summary | 23
TIM-ID: 0000010827 - 003