318 – AL Timing Cylinder B8
ZKP-Number: 18.004.517
Cause
Corrective action
Time-of-flight measuring fault of
injector B8: Time-of flight
measured value extremely low
or extremely high.
u
If alarm occurs frequently, replace solenoid valve of injector
319 – AL Timing Cylinder B9
ZKP-Number: 18.004.518
Cause
Corrective action
Time-of-flight measuring fault of
injector B9: Time-of flight
measured value extremely low
or extremely high.
u
If alarm occurs frequently, replace solenoid valve of injector
320 – AL Timing Cylinder B10
ZKP-Number: 18.004.519
Cause
Corrective action
Time-of-flight measuring fault of
injector B10: Time-of flight
measured value extremely low
or extremely high.
u
If alarm occurs frequently, replace solenoid valve of injector
321 – AL Wiring Cylinder A1
ZKP-Number: 18.004.520
Cause
Corrective action
Short-circuit in injector cabling
to cylinder A1. Result: Misfiring
1. Rectify short circuit in injector solenoid valve circuit (positive to
negative) (e.g. by injector replacement)
2. Error cleared after restarting the engine.
322 – AL Wiring Cylinder A2
ZKP-Number: 18.004.521
Cause
Corrective action
Short-circuit in injector cabling
to cylinder A2. Result: Misfiring
1. Rectify short circuit in injector solenoid valve circuit (positive to
negative) (e.g. by injector replacement)
2. Error cleared after restarting the engine.
MS150048/04E 2013-07 | Troubleshooting | 93