308 – AL Timing Cylinder A8
ZKP-Number: 18.004.507
Cause
Corrective action
Time-of-flight measuring fault of
injector in cylinder A8: Time-of
flight measured value extremely
low or extremely high.
u
If alarm occurs frequently, replace solenoid valve of injector
309 – AL Timing Cylinder A9
ZKP-Number: 18.004.508
Cause
Corrective action
Time-of-flight measuring fault of
injector in cylinder A9: Time-of
flight measured value extremely
low or extremely high.
u
If alarm occurs frequently, replace solenoid valve of injector
310 – AL Timing Cylinder A10
ZKP-Number: 18.004.509
Cause
Corrective action
Time-of-flight measuring fault of
injector in cylinder A10: Time-of
flight measured value extremely
low or extremely high.
u
If alarm occurs frequently, replace solenoid valve of injector
311 – AL Timing Cylinder B1
ZKP-Number: 18.004.510
Cause
Corrective action
Time-of-flight measuring fault of
injector B1: Time-of flight
measured value extremely low
or extremely high.
u
If alarm occurs frequently, replace solenoid valve of injector
312 – AL Timing Cylinder B2
ZKP-Number: 18.004.511
Cause
Corrective action
Time-of-flight measuring fault of
injector B2: Time-of flight
measured value extremely low
or extremely high.
u
If alarm occurs frequently, replace solenoid valve of injector
MS150048/04E 2013-07 | Troubleshooting | 91
TIM-ID: 0000018389 - 003